Galactic cosmic-ray (GCR) energy spectra observed in the inner heliosphere are modulated by the solar activity, the solar polarity and structures of solar and interplanetary origin. A high counting ...rate particle detector (PD) aboard LISA Pathfinder, meant for subsystems diagnostics, was devoted to the measurement of GCR and solar energetic particle integral fluxes above 70 MeV n−1 up to 6500 counts s−1. PD data were gathered with a sampling time of 15 s. Characteristics and energy dependence of GCR flux recurrent depressions and of a Forbush decrease dated 2016 August 2 are reported here. The capability of interplanetary missions, carrying PDs for instrument performance purposes, in monitoring the passage of interplanetary coronal mass ejections is also discussed.
Non-recurrent short-term variations of the galactic cosmic-ray (GCR) flux above 70 MeV n−1 were observed between 2016 February 18 and 2017 July 3 on board the European Space Agency LISA Pathfinder ...(LPF) mission orbiting around the Lagrange point L1 at 1.5 × 106 km from Earth. The energy dependence of three Forbush decreases is studied and reported here. A comparison of these observations with others carried out in space down to the energy of a few tens of MeV n−1 shows that the same GCR flux parameterization applies to events of different intensity during the main phase. FD observations in L1 with LPF and geomagnetic storm occurrence are also presented. Finally, the characteristics of GCR flux non-recurrent variations (peaks and depressions) of duration <2 days and their association with interplanetary structures are investigated. It is found that, most likely, plasma compression regions between subsequent corotating high-speed streams cause peaks, while heliospheric current sheet crossing causes the majority of the depressions.
A torsion pendulum with 2 soft degrees of freedom (DOFs), realized by off-axis cascading two torsion fibers, has been built and operated. This instrument helps characterize the geodesic motion of a ...test mass for LISA Pathfinder or any other free-fall space mission, providing information on cross talk and other effects that cannot be detected when monitoring a single DOF. We show that it is possible to simultaneously measure both the residual force and the residual torque acting on a quasifree test mass. As an example of the investigations that a double pendulum allows, we report the measurement of the force-to-torque cross talk, i.e., the amount of actuation signal, produced by applying a force on the suspended test mass, that leaks into the rotational DOF, detected by measuring the corresponding (unwanted) torque.
The direct detection of high-energy cosmic rays up to the PeV region is one of the major challenges for the next generation of space-borne cosmic-ray detectors. The physics performance will be ...primarily determined by their geometrical acceptance and energy resolution. CaloCube is a homogeneous calorimeter whose geometry allows an almost isotropic response, so as to detect particles arriving from every direction in space, thus maximizing the acceptance. A comparative study of different scintillating materials and mechanical structures has been performed by means of Monte Carlo simulation. The scintillation-Cherenkov dual read-out technique has been also considered and its benefit evaluated.
Given the good performances in terms of geometrical acceptance and energy resolution, calorimeters are the best suited detectors to measure high energy cosmic rays directly in space. However, in ...order to exploit this potential, the design of calorimeters must be carefully optimized to take into account all limitations related to space missions, due mainly to the mass of the experimental apparatus. CaloCube is a three years R&D project, approved and financed by INFN in 2014, aiming to optimize the design of a space-borne calorimeter by the use of a cubic, homogeneous and isotropic geometry. In order to maximize detector performances with respect to the total mass of the apparatus, comparative studies on different scintillating materials, different sizes of crystals and different spacings among them have been performed making use of Monte Carlo simulations. In parallel to this activity, several prototypes instrumented with CsI:Tl cubic crystals have been constructed and tested with particle beams (muons, electrons, protons and ions). Both simulations and prototypes showed that the CaloCube design leads to a good particle energy resolution (< 2% for electromagnetic showers, < 40% for hadronic showers) and a good effective geometric factor (> 3:5 m2 sr for electromagnetic showers, > 2:5 m2 sr for hadronic showers). Thanks to these performances, in 5 years of operation it would be possible to measure the ux of electrons+positrons up to some tens of TeV and the uxes of protons and nuclei up to some units of PeV/nucleon, hence extending these measurements by at least one order of magnitude in energy compared to the experiments currently operating in space.