Purpose
Residual feeling of leg length discrepancy (LLD) is a common cause of patient dissatisfaction following total hip arthroplasty (THA). The purpose of this study is to propose a method for ...determining an optimal leg length correction goal in THA.
Methods
We conducted a retrospective study of 132 patients to examine the radiographic LLD (R-LLD), perceived LLD (P-LLD), and whether or not the patient has an uncomfortable feeling about the leg length after THA.
Results
The residual discomfort rate in all patients was 9.1% (12/132 patients), and ten of these 12 patients felt uncomfortable due to a longer leg length. When R-LLD was within 7 mm, the rate was 6.8% (8/118 patients), which is nearly equal to the rate of 7.8% (5/64 patients) in cases in which R-LLD was within 2 mm. On the other hand, when R-LLD was 8 mm or more, the rate was 57.1% (4/7 patients).
Conclusions
The results of our study show that 7 mm may be a reasonable threshold for reducing the residual discomfort. However, even with little or no R-LLD, some patients will continue to experience discomfort. We think that this is because of pre-operative differences between R-LLD and P-LLD in such cases. If the patient has a pelvic declination on the affected hip side and a lumbar scoliosis angle that is convex toward the affected hip side before surgery, the ideal length may be a little shorter than the radiographic isometry, since such patients are likely to feel a longer leg length than that shown radiographically.
Groin pain and functional limitations may occur after total hip arthroplasty (THA) due to iliopsoas impingement (IPI). We aimed to determine the risk factors and thresholds of cup protrusion for ...symptomatic IPI.
This retrospective case-control study evaluated 569 primary THAs performed by a single surgeon in a single center. In all THAs, the cup was inserted with the assistance of the computed tomography–based navigation system. Twenty-two THAs (3.9%) were identified to have symptoms of IPI and included in the IPI group. Control group 1 comprised 547 THAs. Control group 2 (66 THAs) was formed by recruiting 3 data-matched controls per patient in control group 1. Risk factors for IPI were assessed in the IPI group and control group 1. Further analysis was performed in the IPI group and control group 2 to evaluate cup protrusion parameters measured on computed tomography images and radiographs.
Multivariate logistic regression analysis confirmed that the anterolateral approach was associated with a higher risk of IPI (odds ratio OR, 4.20); however, its goodness of fit was low. Axial protrusion length ≥12 mm (OR, 23.29; sensitivity = 72.7; specificity = 91.0) and sagittal protrusion length ≥4 mm (OR, 61.60; sensitivity = 86.4; specificity = 78.8) were determined as independent predictors of symptomatic IPI. In the linear regression analyses, higher native acetabular version and lower cup anteversion and inclination were related to cup protrusion.
This study determined the thresholds of cup protrusion length for IPI and identified associated factors increasing cup protrusion, which are useful for surgeons in determining cup position and alignment.
We developed iodine-coated titanium implants to suppress microbial activity and prevent periprosthetic joint infection (PJI); their efficacy was demonstrated in animal and in vitro models. The iodine ...content in iodine-coated implants naturally decreases in vivo. However, to our knowledge, the effect of reduced iodine content on the implant's antimicrobial activity has not been evaluated to date.
(1) How much does the iodine content on the implant surface decrease after 4 and 8 weeks in vivo in a rat model? (2) What effect does the reduced iodine content have on the antimicrobial effect of the implant against multiple bacteria in an in vitro model?
This experiment was performed in two parts: an in vivo experiment to determine attenuation of iodine levels over time in rats, and an in vitro experiment in which we sought to assess whether the reduced iodine content observed in the in vivo experiment was still sufficient to deliver antimicrobial activity against common pathogens seen in PJI. For the in vivo experiment, three types of titanium alloy washers were implanted in rats: untreated (Ti), surface-anodized to produce an oxide film (Ti-O), and with an iodine layer on the oxidation film (Ti-I). The attenuation of iodine levels in rats was measured over time using inductively coupled plasma-mass spectrometry. Herein, only the Ti-I washer was used, with five implanted in each rat that were removed after 4 or 8 weeks. For the 4- and 8-week models, two rats and 15 washers were used. For the in vitro study, to determine the antibacterial effect, three types of washers (Ti, Ti-O, and Ti-I) (nine washers in total) were implanted in each rat. Then, the washers were removed and the antibacterial effect of each washer was examined on multiple bacterial species using the spread plate method and fluorescence microscopy. For the spread plate method, six rats were used, and five rats were used for the observation using fluorescence microscopy; further, 4- and 8-week models were made for each method. Thus, a total of 22 rats and 198 washers were used. Live and dead bacteria in the biofilm were stained, and the biofilm coverage percentage for quantitative analysis was determined using fluorescence microscopy in a nonblinded manner. Ti-I was used as the experimental group, and Ti and Ti-O were used as control groups. The total number of rats and washers used throughout this study was 24 and 213, respectively.
Iodine content in rats implanted with Ti-I samples decreased to 72% and 65% after the in vivo period of 4 and 8 weeks, respectively (p = 0.001 and p < 0.001, respectively). In the in vitro experiment, the Ti-I implants demonstrated a stronger antimicrobial activity than Ti and Ti-O implants in the 4- and 8-week models. Both the median number of bacterial colonies and the median biofilm coverage percentage with live bacteria on Ti-I were lower than those on Ti or Ti-O implants for each bacterial species in the 4- and 8-week models. There was no difference in the median biofilm coverage percentage of dead bacteria. In the 8-week model, the antibacterial activity using the spread plate method had median (interquartile range) numbers of bacteria on the Ti, Ti-O, and Ti-I implants of 112 (104 to 165) × 105, 147 (111 to 162) × 105, and 55 (37 to 67) × 105 of methicillin-sensitive Staphylococcus aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.009); 71 (39 to 111) × 105, 50 (44 to 62) × 105, and 26 (9 to 31)× 105 CFU of methicillin-resistant S. aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.034); and 77 (74 to 83) × 106, 111 (95 to 117) × 106, and 30 (21 to 45) × 106 CFU of Pseudomonas aeruginosa (Ti-I versus Ti, p = 0.004; Ti-I versus Ti-O, p = 0.009). Despite the decrease in the iodine content of Ti-I after 8 weeks, it demonstrated better antibacterial activity against all tested bacteria than the Ti and Ti-O implants.
Iodine-coated implants retained their iodine content and antibacterial activity against methicillin-sensitive S. aureus, methicillin-resistant S. aureus, and P. aeruginosa for 8 weeks in vivo in rats. To evaluate the longer-lasting antibacterial efficacy, further research using larger infected animal PJI models with implants in the joints of both males and females is desirable.
Iodine-coated titanium implants displayed an antibacterial activity for 8 weeks in rats in vivo. Although the findings in a rat model do not guarantee efficacy in humans, they represent an important step toward clinical application.
Background
Periprosthetic fractures of the acetabulum occurring during primary THA are rare. Periprosthetic occult fractures are defined as those not identified by the surgeon during the procedure ...which might be missed on a routine postoperative radiograph. However, it is unclear how frequently these fractures occur and whether their presence affects functional recovery.
Questions/Purposes
In this study, using routine CT scans that were obtained as part of another primary hip arthroplasty study protocol, we retrospectively assessed (1) the prevalence of occult fractures of the acetabulum occurring during primary THA, (2) the location of occult fractures of the acetabulum during THA, and (3) risk factors contributing to such occult fractures.
Methods
Between 2004 and 2013, our institute performed 585 primary THAs (cementless or hybrid) in 494 patients with DICOM pre- and postoperative CT; during the period in question, all patients undergoing THA underwent CT before and after surgery. Preoperative CT images were taken as part of a CT-based three-dimensional templating software and navigation system. Postoperative CT images were taken an average of 1 week after surgery as part of a different protocol to evaluate cup position, restoration of leg length and offset, volume of postoperative hematoma to assess anticoagulation effects after THA, and fractures that were not found on routine postoperative radiographs (which we defined as occult fractures). Patients with a history of prior pelvic osteotomy, trauma, and infection were excluded (88 patients/99 hips); 406 patients (102 males and 304 females; 486 hips) form the basis of this report. The mean age of the patients was 60 ± 11 years, with a mean BMI of 23 ± 4 kg/m
2
. The mean followup of the patients with periprosthetic fracture of the acetabulum was 58 ± 28 months (range, 12–131 months). Potential risk factors for occult acetabular fracture including age, sex, BMI, preoperative diagnosis, additional dome screw fixation, composition and size of each cup, and acetabular design were examined in multivariate analysis. Acetabular component designs were categorized as true hemispheric, peripheral self-locking, and elliptical; during the period in question the indications for each cup design were based on the brand of stem used. Comparison between preoperative and postoperative CT images was done to detect the fractures. Patients with fractures identified during surgery were treated with additional dome screw fixation and a 3-week period of nonweightbearing. Patients with occult fractures in this series did not receive additional treatment as we had confirmed secure fixation of the cup during surgery.
Results
Occult fractures occurred in 41 hips (8.4%); periprosthetic fractures of the acetabulum were seen during surgery in an additional two hips (0.4%). The superolateral wall was the most frequent location for occult fractures of the acetabulum. After controlling for relevant confounding variables, only the use of peripheral self-locking cups was associated with an increased risk of occult fracture (odds ratio OR, 2.6 compared with hemispheric cups; 95% CI, 1.2–5.6; p < 0.05). All patients with occult fractures showed bone ingrowth fixation at the final followup, without any additional surgical intervention.
Conclusions
Periprosthetic occult fractures of the acetabulum may occur relatively frequently during press-fit impaction. We observed a higher rate of fractures associated with the use of peripheral self-locking components. Occult acetabular fractures not detected on routine postoperative plain films may be ignored if secure fixation of the cup has been confirmed during the operation.
Level of Evidence
Level III, therapeutic study.
This report seeks to clarify whether the dosage and duration of preoperative concurrent corticosteroid use influence postoperative complications after primary total joint arthroplasty (TJA).
This ...retrospective single institutional study enrolled 1128 primary TJA cases, including 905 total hip arthroplasties and 223 total knee arthroplasties at a minimum 6 months of follow-up. Mean follow-up period was 51.9 ± 34.1 months (range 6-146). Of all joints, 120 joints (10.6%) were associated with chronic concurrent oral corticosteroid use. Multivariate analysis was performed to identify whether chronic concurrent oral corticosteroid use elevated the risk of postoperative complications including surgical site infection/periprosthetic joint infection, delayed wound healing, periprosthetic fracture, and implant loosening. For chronic concurrent oral corticosteroid user, we determined whether the dosage and duration of preoperative concurrent corticosteroid use influenced postoperative complications and have an effective threshold for postoperative complications using receiver operating characteristic curve analysis.
The multivariate analysis revealed that American Society of Anesthesiologist Physical Status 3 was an independent risk factor for postoperative complications, while concurrent oral corticosteroid use was not an independent risk factor. When we compared joints with (n = 13) and without (n = 107) postoperative complications in chronic concurrent oral corticosteroid user, there was no statistical difference in the dosage (P = .97) and duration (P = .69) between the 2 groups. Area under the curve values for the oral corticosteroid dosages and duration were 0.482 and 0.549, respectively.
This study revealed that neither dosage nor duration of concurrent oral corticosteroid use was predictive of postoperative complications after TJA. American Society of Anesthesiologist Physical Status 3 is a major factor in postoperative complications after TJA.
We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measuring hip-knee-ankle (HKA) angle in patients with knee osteoarthritis, by comparing it with ...radiography. In this prospective study, we analysed 60 knees (30 patients) with knee osteoarthritis. We measured HKA angle using OpenPose and radiography before or after total knee arthroplasty and assessed the test-retest reliability of each method with intraclass correlation coefficient (1, 1). We evaluated the ability to estimate the radiographic measurement values from the OpenPose values using linear regression analysis and used intraclass correlation coefficients (2, 1) and Bland-Altman analyses to evaluate the agreement and error between OpenPose and radiographic measurements. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1, 1) = 1.000) and excellent agreement with radiography (intraclass correlation coefficient (2, 1) = 0.915), with regression analysis indicating a large correlation (R
= 0.865). OpenPose also had a 1.1° fixed error and no systematic error when compared with radiography. This is the first study to validate the use of OpenPose for the estimation of HKA angle in patients with knee osteoarthritis. OpenPose is a reliable and valid tool for measuring HKA angle in patients with knee osteoarthritis. OpenPose, which enables non-invasive and simple measurements, may be a useful tool to assess changes in HKA angle and monitor the progression and post-operative course of knee osteoarthritis. Furthermore, this validated tool can be used not only in clinics and hospitals, but also at home and in training gyms; thus, its use could potentially be expanded to include self-assessment/monitoring.
Abstract
Understanding the morphology of the superior aspect of the proximal femur is critical for treating femoral fracture. We assessed the correlation among the ideal insertion point of the ...femoral nail, femur head-neck axis, and native anteversion. One hundred patients with normal femurs were included in this study. Computed tomography (CT) images of the proximal femur superior aspect and amount of native anteversion were acquired. Generalised Procrustes analysis showed the morphological characteristics of the superior proximal femur according to native anteversion amount. Morphological characteristics were represented by 4 parameters; the correlation between parameters and native anteversion was investigated using CT data. The passing point of the line from the proximal femoral canal parallel to the native anteversion at the greater trochanter was located more posteriorly (mean 35.6%); the passing point of native anteversion was posterior in the femoral neck and head, although the line of the head-neck centre passed more anteriorly at the greater trochanter (mean 67.5%). This posterior translation was significantly associated with native anteversion amount. Morphometric geometric analysis showed that the lag screw could not pass head-neck centre from the nail inserted into proximal femoral canal. Anterior insertion of the nail was needed for positioning the lag screw centre.
Periprosthetic joint infection (PJI) is characterized by biofilm infection, which is difficult to alleviate while preserving implant integrity. Furthermore, long-term antibiotic therapy may increase ...the prevalence of drug-resistant bacterial strains, necessitating a non-antibacterial approach. Adipose-derived stem cells (ADSCs) exert antibacterial effects; however, their efficacy in PJI remains unclear. This study investigates the efficacy of combined intravenous ADSCs and antibiotic therapy in comparison to antibiotic monotherapy in a methicillin-sensitive Staphylococcus aureus (MSSA)-infected PJI rat model. The rats were randomly assigned and equally divided into 3 groups: no-treatment group, antibiotic group, ADSCs with antibiotic group. The ADSCs with antibiotic group exhibited the fastest recovery from weight loss, with lower bacterial counts (p = 0.013 vs. no-treatment group; p = 0.024 vs. antibiotic group) and less bone density loss around the implants (p = 0.015 vs. no-treatment group; p = 0.025 vs. antibiotic group). The modified Rissing score was used to evaluate localized infection on postoperative day 14 and was the lowest in the ADSCs with antibiotic group; however, no significant difference was observed between the antibiotic group and ADSCs with antibiotic group (p < 0.001 vs. no-treatment group; p = 0.359 vs. antibiotic group). Histological analysis revealed a clear, thin, and continuous bony envelope, a homogeneous bone marrow, and a defined, normal interface in the ADSCs with antibiotic group. Moreover, the expression of cathelicidin expression was significantly higher (p = 0.002 vs. no-treatment group; p = 0.049 vs. antibiotic group), whereas that of tumor necrosis factor (TNF)-α and interleukin(IL)-6 was lower in the ADSCs with antibiotic group than in the no-treatment group (TNF-α, p = 0.010 vs. no-treatment group; IL-6, p = 0.010 vs. no-treatment group). Thus, the combined intravenous ADSCs and antibiotic therapy induced a stronger antibacterial effect than antibiotic monotherapy in a MSSA-infected PJI rat model. This strong antibacterial effect may be related to the increased cathelicidin expression and decreased inflammatory cytokine expression at the site of infection.
Abstract
Background
Perioperative greater trochanteric fracture following total hip arthroplasty (THA) using the anterolateral approach is a recognized perioperative complication. There was no ...previous study to determine the relationship between bone mineral density (BMD) and three-dimensional greater trochanter morphology for perioperative greater trochanter fractures. The purpose of this study is to identify the influence of greater trochanteric bone density and three-dimensional morphology on perioperative greater trochanteric fracture following THA using the anterolateral approach.
Methods
We investigated 209 hips done primary THA using the anterolateral approach and preoperative BMD test for the proximal femoral bone with a minimum of 6 months follow-up. We picked up all patients who had perioperative greater trochanteric fractures. Multivariate analysis was done in order to investigate the influence of the greater trochanter young adult mean (YAM) and three-dimensional morphology on perioperative greater trochanteric fractures.
Results
There were 10 joints (10/209, 4.8%) with perioperative greater trochanteric fractures. Osteosynthesis was required only in one joint (1/209, 0.5%) because the bone fragments were significantly displaced proximally by the gluteus medius. Multivariate analysis showed the combination of Type B femoral shape (in cases where the top of the great trochanter was inside the longitudinal central axis of the planned femoral stem in computed tomography (CT)- based three-dimensional templating) and a YAM of < 80% was the only risk factor for fracture.
Conclusions
The preoperative greater trochanter BMD test (YAM < 80%) and three-dimensional femoral morphology (Type B femoral shape) provide useful information to mitigate the occurrence of perioperative greater trochanter fractures associated with THA using the anterolateral approach.
Surgical site infection (SSI) is a common complication following orthopedic implantation. We developed an iodine coating for titanium implants to reduce implant-related infections and conducted a ...prospective clinical study to evaluate the efficacy and potential drawbacks of iodine-supported implants.
Between July 2008 and July 2017, 653 patients (377 male and 27 female patients; mean age, 48.6) with postoperative infection or a compromised status were treated using iodine-loaded titanium implants. The mean follow-up period was 41.7 months. In 477 patients, iodine-supported implants were used to prevent infection and in 176 patients, to treat active infection (one-stage surgery, 89 patients; two-stage surgery, 87 patients). In the limbs and pelvis, the primary diagnoses included the following: 161 tumors, 92 deformities/shortening, 47 pseudarthrosis, 42 fractures, 32 infected TKA, 25 osteoarthritis, 21 pyogenic arthritis, 20 infected THA, and 6 osteomyelitis. In the spinal cases, there were 136 cases of tumors, 36 cases of pyogenic spondylitis, and 35 cases of degeneration. Five modes of implant failure were identified and classified as follows: soft tissue failure (type 1), aseptic loosening (type 2), structural failure (type 3), infection (type 4), and tumor progression (type 5).
The overall failure rate in our series was 26.3% (172/653). There were 101 mechanical failures, including 22 type 1, 20 type 2, and 59 type 3 failures. Non-mechanical causes accounted for 71 failures, including 45 type 4 and 26 type 5 failures. The overall incidence of infections was 6.8%. The mean time to the onset of infection after implantation was 9.1 months. The overall infection rate was 3.7% in the prevention cases and 15.3% in the treatment cases. There was no difference between one-stage replacement (14.6%) and two-stage replacement (16.0%). There were 11 cases of treatment for SSI of spine surgery, and the re-infection rate was 0% using iodine-coated instruments.
The five modes of failure of the iodine-supported implant were satisfactory compared with previous reports. In particular, because the infection rate of iodine-coated implants used for compromised hosts is low compared with other methods, postoperative infection is more easily controlled. It can be considered highly effective for spinal infections that require one-stage revision surgery.
Trial registration Prospective, Observation study.