In three different dairies (A, B and C) located in Peloponess region (Southern Greece), traditional Feta cheese trials took place February to March using mixtures of sheep's and goat's milk. Only ...small variations in the evolution of microbial groups were observed during the whole ripening period. The main groups, such as thermophilic cocci, mesophilic lactococci, thermophilic lactobacilli, nonstarter lactic acid bacteria (NSLAB), presumptive
Leuconostoc, enterococci and micrococci, reached their highest levels during the first 16 days, and then declined approximately 1–2 log units until the end of ripening. The remaining groups investigated, comprising yeasts, coliforms and
Escherichia coli, were highest at day 4. The yeasts remained constant, while coliforms and
E. coli decreased sharply and were not detectable after 120 days of ripening. A number of 146 isolates (dairy A) taken from all stages of the manufacturing and ripening process were purified and studied.
Lactobacillus plantarum (58/146) and isolates of related species
Lactobacillus pentosus and
Lactobacillus paraplantarum (16/146) were the most common microorganisms found during cheese ripening.
Streptococcus thermophilus (23/146) and
Lactobacillus delbrueckii subsp.
bulgaricus (20/146) were detected in high levels up to 20 days, and then gradually reduced.
Enterococcus faecium (29/146) was found in all manufacturing and ripening stages.
Fundamental imaging performance in terms of Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE) was investigated for a high resolution CMOS based ...imaging sensor. The device consists of a 33.91 mg/cm 2 Gd 2 O 2 S:Tb scintillator screen, placed in direct contact with a CMOS photodiode array. The CMOS photodiode array, featuring 1200×1600 pixels with a pixel pitch of 22.5 μm, was used as an optical photon detector. In addition to the conventional frequency dependent parameters characterizing image quality, image information content was assessed through the application of information capacity (IC). The MTF was measured using the slanted-edge method to avoid aliasing while the Normalized NPS (NNPS) was determined by two-dimensional (2D) Fourier transforming of uniformly exposed images. Both measurements were performed under the representative radiation quality (RQA) settings, RQA-5 (70 kVp digital-radiography) and RQA-M2 (28 kVp digital-mammography) recommended by the International Electrotechnical Commission Reports 62220-1 and 62220-1-2 respectively. The DQE was assessed from the measured MTF, NPS and the direct entrance surface air-Kerma (ESAK) obtained from X-ray spectra measurement with a portable cadmium telluride (CdTe) detector. The ESAK values ranged between 11-87 μGy for RQA-5 and 6-40 μGy for RQA-M2. Additionally the output electrons per X-ray photon of the detector and its signal transfer characteristics were assessed via an analytical model, within the framework of the linear cascaded systems (LCS) theory. It was found that the detector response function was linear for the exposure ranges under investigation. Additionally our results showed that for the same RQA quality the output electrons per X-ray photon, as well as the measured and analytically predicted MTF, were not significantly affected by ESAK. MTF and DQE where found better compared to previously published data for other CCD and CMOS sensors, while the NNPS appeared to be comparable in the frequency range under investigation (0-10 cycles/mm).
The aim of the present study is to introduce the detective quantum efficiency (DQE) for the image quality assessment of positron emission tomography (PET) scanners. For this purpose, a thin layer ...chromatography (TLC) plane source was simulated using a previously validated, scanner and source geometry, Monte Carlo (MC) model. The model was developed with the Geant4 application for tomographic emission (GATE) MC package and reconstructed images obtained with the software for tomographic image reconstruction (STIR), with cluster computing. The GE Discovery ST PET scanner was simulated by using a previously validated code. A plane source consisting of a TLC plate, was simulated by a layer of silica gel on aluminum (Al) foil substrate, immersed in 18F-FDG bath solution (1MBq). Image quality was assessed in terms of the modulation transfer function (MTF) and the normalized noise power spectrum (NNPS) in order to obtain the detective quantum efficiency (DQE). MTF curves were estimated from transverse reconstructed images of the plane source, whereas the NNPS data were estimated from the corresponding coronal images. Images were reconstructed by the maximum likelihood estimation ordered subsets maximum a posteriori one step late (MLE)-OS-MAP-OSL algorithm, by using various subsets 1–21) and iterations 1–20). MTF values were found to increase up to the 12th iteration whereas remain almost constant thereafter. However, the range of the increase in the MTF is limited as the number of subsets increases. The noise levels were found to increase with the corresponding increase of both the number of iterations and subsets. The maximum NNPS value (0.517mm2) was observed for the 420 MLEM-equivalent iterations reconstructed image at 0cycles/mm. Finally DQE values were found to increase for spatial frequencies up to 0.038cycles/mm and to decrease thereafter with the corresponding increase in both number of iterations and subsets. The maximum DQE value (0.48 at 0.038cycles/mm) was obtained for the 8 MLEM-equivalent iterations image. The simulated PET evaluation method based on the TLC plane source can be useful in the quality control and in the further development of PET and SPECT scanners though GATE simulations.
•Introduction of the DQE for the image quality assessment of PET scanners.•A thin layer chromatography source was simulated using GATE Monte Carlo.•MTF was found to increase up to 12 iterations and remain constant thereafter.•Noise was found to increase when the number of iterations and subsets increase.•DQE was found to decrease upon increase of iterations and subsets.
Objectives. In this work, a simple technique to assess the image quality characteristics of the postprocessed image is developed and an easy to use figure of image quality (FIQ) is introduced. This ...FIQ characterizes images in terms of resolution and noise. In addition information capacity, defined within the context of Shannon’s information theory, was used as an overall image quality index. Materials and Methods. A digital mammographic image was postprocessed with three digital filters. Resolution and noise were calculated via the Modulation Transfer Function (MTF), the coefficient of variation, and the figure of image quality. In addition, frequency dependent parameters such as the noise power spectrum (NPS) and noise equivalent quanta (NEQ) were estimated and used to assess information capacity. Results. FIQs for the “raw image” data and the image processed with the “sharpen edges” filter were found 907.3 and 1906.1, correspondingly. The information capacity values were 60.86 × 10 3 and 78.96 × 10 3 bits/mm2. Conclusion. It was found that, after the application of the postprocessing techniques (even commercial nondedicated software) on the raw digital mammograms, MTF, NPS, and NEQ are improved for medium to high spatial frequencies leading to resolving smaller structures in the final image.
The aim of the present study was to propose a comprehensive method for positron emission tomography (PET) scanners image quality assessment, by simulation of a thin layer chromatography (TLC) flood ...source with a previously validated Monte Carlo model.
We used the GATE Monte Carlo package (GEANT4 application for tomographic emission) and the reconstructed images were obtained using the software for tomographic image reconstruction (STIR), with cluster computing. The PET scanner used in this simulation study was the General Electric Discovery-ST (USA). The plane source that was used for the image quality assessment was a TLC plate, consisting of an aluminum (Al) foil, coated with a thin layer of silica and immersed in fluorodeoxyglucose (
F-FDG) bath solution (1 MBq). The influence of different scintillating crystals on PET scanner's image quality, in terms of the modulation transfer function (MTF), the normalized noise power spectrum (NNPS) and the detective quantum efficiency (DQE), were also investigated. Modulation transfer function was estimated from transverse slices of the plane source, whereas the NNPS from the corresponding coronal slices. Images were reconstructed by the commonly used 2D filtered back projection (FBP2D), the Kinahan and Rogers FPB3DRP and the maximum likelihood estimation (MLE)-OSMAPOSL algorithms. Images obtained using the OSMAPOSL algorithm were assessed by using 15 subsets and 3 iterations.
The PET scanner configuration, equipped with LuAP crystals, exhibited the optimum MTF values in both 2D and 3D FBP image reconstruction, whereas the corresponding configuration with BGO crystals exhibited the optimum MTF values after the iterative algorithm. The scanner equipped with the BGO crystals was also found to exhibit overall the lowest noise levels and the highest DQE values after algorithms. These finding indicate that the GE Discovery ST PET scanner exhibits the optimum image quality parameters, in terms of MTF, NNPS and DQE, with BGO scintillating crystals.
Our new method showed that the imaging performance of PET scanners can be fully characterized and further improved by investigation of the imaging chain components through Monte Carlo methods. To this aim, a TLC based plane source was used during the simulation, in order to assess the impact of the scintillating crystal material on PET image quality, with the application of a previously validated Monte Carlo model. The aforementioned plane source can be also useful for the further development of PET and SPET scanners through GATE simulations, for clinical applications.
Lutetium–yttrium-based scintillators, such as LYSO:Ce, have a high effective atomic number, are non-hygroscopic, fast emitting materials, and promising candidates for use in positron emission ...imagers. The present study investigates the light emission characteristics of (Lu, Y)
2SiO
5:Ce (LYSO:Ce) single-crystal scintillator under X-ray imaging conditions. Also, the parameters related to the luminescence emission spectrum and emission efficiency were studied using experimental methods. Various X-ray tube voltages currently employed in X-ray imaging techniques were used. Measurements were performed using an experimental set-up based on a photomultiplier coupled to an integration sphere. In addition, the emission spectrum under UV and X-ray excitation was measured using an optical grating monochromator to determine the spectral compatibility of optical photon detectors incorporated in medical imaging systems. The absolute efficiency of LYSO:Ce was found to increase with increasing X-ray tube voltage (from 2.2
EU at 22
kVp to 22.4
EU at 140
kVp), while its spectrum, peaking at about 430
nm, was found compatible with most optical detectors (photodiodes, photocathodes, charge coupled devices, etc.). The matching factor was estimated to range from 0.76 to 0.92 (for a silicon photodiode and for a GaAsP photocathode, respectively).
The aim of the present work is to study the performance of scintillators currently used in PET and animal PET systems, under conditions met in radiation therapy and PET/CT imaging. The results of ...this study will be useful in applications where both CT and PET photons as well as megavoltage cone beam CT (MV CBCT) photons could be detected using a common detector unit. To this aim crystal samples of GSO, LSO, LYSO, LuYAP and YAP scintillators, doped with cerium (Ce +3 ) were examined under a wide energy range of photon energies. Evaluation was performed by determining the absolute luminescence efficiency (emitted light flux over incident X-ray exposure) in the energy range employed in X-ray CT, in Nuclear Medicine (70 keV up to 662 keV) and in radiotherapy 6 MV (approx. 2.0 MeV mean energy)-18 MV (approx. 4.5 MeV mean energy). Measurements were performed using an experimental set-up based on a photomultiplier coupled to a light integration sphere. The emission spectrum under X-ray excitation was measured, using an optical grating monochromator, to determine the spectral compatibility to optical photon detectors incorporated in medical imaging systems. Maximum absolute luminescence efficiency values were observed at 70 keV for YAP:Ce and LuYAP:Ce and at 140 keV for LSO:Ce, LYSO:Ce and GSO:Ce. Highest absolute efficiency between the scintillators examined was observed for LSO:Ce, followed by LYSO:Ce. The detector optical gain (DOG) exhibited a significant variation with the increase of energy between 70 keV to 2.0 MeV. All scintillators exhibited low compatibility when combined with GaAsP (G5645) photodetector.
Information Content in Nuclear Medicine Imaging Michail, Christos M.; Agavanakis, Kyriakos N.; Karpetas, George. E. ...
Energy procedia,
January 2019, 2019-01-00, Volume:
157
Journal Article
Peer reviewed
Open access
The aim of the present study was to investigate the information content of positron emission tomography (PET) images. We used the GATE Monte Carlo package (GEANT4 application for tomographic ...emission) and reconstructed images, obtained using the software for tomographic image reconstruction (STIR). The case study for the investigation of the PET images information content was the General Electric Discovery-ST (USA) PET scanner. A thin film plane source aluminum (Al) foil, coated with a thin layer of silica and a fluorodeoxyglucose (18F-FDG) bath distribution of (1 MBq) was used in the simulation for the image signal to noise ratio assessment. The influence of the maximum likelihood estimation ordered subsets maximum a posteriori one step late (MLE)-OS-MAP-OSL algorithm, using various subsets (1 to 21) and iterations (1 to 20) was examined. The image information content was assessed in terms of the information capacity (IC). Results showed that the single index information capacity maximized for the range of 8-20 iterations and 3 subsets. In conclusion, our study showed that the image information content of PET scanners can be fully characterized and further improved by investigation of the imaging chain components through Monte Carlo methods. Moreover, new perspectives are created by using the suggested techniques in the context of a global cloud service that could serve as an online quality evaluation metric for the PET scanners and other medical imaging systems.
The objective of this work was to study the characteristics of the gastric aspartic proteinases chymosin and pepsin which are constituents of the kid rennet. The two enzymes were extracted from ...abomasal tissue of one kid from a local indigenous breed, separated from each other by DEAE-cellulose chromatography and then were purified by gel filtration and anion-exchange chromatography. The molecular weights of the purified kid chymosin and pepsin as determined by gel filtration were 36 kDa and 40 kDa respectively. The isoelectric point of kid chymosin was as multiple forms of 3-6 zones at pH 4.6-5.1, while that of kid pepsin was at pH less than or equal to 3.0. Kid pepsin contained 0.37 molecules phosphorous per molecule and was totally inhibited by 5 micromolar pepstatin A, being more sensitive than kid chymosin. Both enzymes were almost equally as proteolytic as calf chymosin on total casein at pH 5.6. Kid pepsin activity was more pH and temperature dependent than kid chymosin activity. In comparison with the calf chymosin temperature sensitivity, the order of increased sensitivity was: calf chymosin <kid chymosin <kid pepsin.
The aim of the present study was to investigate the imaging transfer characteristics and the luminescence efficiency (XLE) of Gd 2 O 2 S:Eu powder scintillator for use in X-ray mammography detectors. ...Gd 2 O 2 S:Eu emits in the red part of the visible spectrum, having very good spectral compatibility with optical sensors employed in digital imaging systems. Three Gd 2 O 2 S:Eu powder scintillating screens, with coating thicknesses 33.1, 46.4 and 63.1 mg/cm 2 , were prepared in our laboratory. The imaging performance of these screens was assessed by experimental determination of the modulation transfer function (MTF), the noise transfer function (NTF) and the detective quantum efficiency (DQE) as well as a single index image quality parameter such as the information capacity (IC). A theoretical model, describing radiation and light transfer, was used to fit experimental MTF data. This has allowed the estimation of optical attenuation coefficients of the scintillator. In addition, a previously validated Monte Carlo code, based on the X-ray attenuation properties and on the Mie light scattering theory, was used to estimate the X-ray detection efficiency, the Swank factor and the zero frequency DQE of the Gd 2 O 2 S:Eu scintillator. Results showed that Gd 2 O 2 S:Eu exhibits high MTF and DQE values, which are comparable to those of a commercially employed Gd 2 O 2 S:Tb screen. In addition Gd 2 O 2 S:Eu shows high compatibility (effective gain) to CCDs and to recently introduced CMOS based detectors. Considering our image quality parameters and luminescence efficiency results, this material can potentially be considered for use in digital X-ray mammography detectors.