Recently, metasurfaces composed of artificially fabricated subwavelength structures have shown remarkable potential for the manipulation of light with unprecedented functionality. Here, we first ...demonstrate a metasurface application to realize a compact near-eye display system for augmented reality with a wide field of view. A key component is a see-through metalens with an anisotropic response, a high numerical aperture with a large aperture, and broadband characteristics. By virtue of these high-performance features, the metalens can overcome the existing bottleneck imposed by the narrow field of view and bulkiness of current systems, which hinders their usability and further development. Experimental demonstrations with a nanoimprinted large-area see-through metalens are reported, showing full-color imaging with a wide field of view and feasibility of mass production. This work on novel metasurface applications shows great potential for the development of optical display systems for future consumer electronics and computer vision applications.
To identify genetic factors influencing quantitative traits of biomedical importance, we conducted a genome-wide association study in 8,842 samples from population-based cohorts recruited in Korea. ...For height and body mass index, most variants detected overlapped those reported in European samples. For the other traits examined, replication of promising GWAS signals in 7,861 independent Korean samples identified six previously unknown loci. For pulse rate, signals reaching genome-wide significance mapped to chromosomes 1q32 (rs12731740, P = 2.9 x 10(-9)) and 6q22 (rs12110693, P = 1.6 x 10(-9)), with the latter approximately 400 kb from the coding sequence of GJA1. For systolic blood pressure, the most compelling association involved chromosome 12q21 and variants near the ATP2B1 gene (rs17249754, P = 1.3 x 10(-7)). For waist-hip ratio, variants on chromosome 12q24 (rs2074356, P = 7.8 x 10(-12)) showed convincing associations, although no regional transcript has strong biological candidacy. Finally, we identified two loci influencing bone mineral density at multiple sites. On chromosome 7q31, rs7776725 (within the FAM3C gene) was associated with bone density at the radius (P = 1.0 x 10(-11)), tibia (P = 1.6 x 10(-6)) and heel (P = 1.9 x 10(-10)). On chromosome 7p14, rs1721400 (mapping close to SFRP4, a frizzled protein gene) showed consistent associations at the same three sites (P = 2.2 x 10(-3), P = 1.4 x 10(-7) and P = 6.0 x 10(-4), respectively). This large-scale GWA analysis of well-characterized Korean population-based samples highlights previously unknown biological pathways.
Most trials comparing percutaneous coronary intervention (PCI) with coronary-artery bypass grafting (CABG) have not made use of second-generation drug-eluting stents.
We conducted a randomized ...noninferiority trial at 27 centers in East Asia. We planned to randomly assign 1776 patients with multivessel coronary artery disease to PCI with everolimus-eluting stents or to CABG. The primary end point was a composite of death, myocardial infarction, or target-vessel revascularization at 2 years after randomization. Event rates during longer-term follow-up were also compared between groups.
After the enrollment of 880 patients (438 patients randomly assigned to the PCI group and 442 randomly assigned to the CABG group), the study was terminated early owing to slow enrollment. At 2 years, the primary end point had occurred in 11.0% of the patients in the PCI group and in 7.9% of those in the CABG group (absolute risk difference, 3.1 percentage points; 95% confidence interval CI, -0.8 to 6.9; P=0.32 for noninferiority). At longer-term follow-up (median, 4.6 years), the primary end point had occurred in 15.3% of the patients in the PCI group and in 10.6% of those in the CABG group (hazard ratio, 1.47; 95% CI, 1.01 to 2.13; P=0.04). No significant differences were seen between the two groups in the occurrence of a composite safety end point of death, myocardial infarction, or stroke. However, the rates of any repeat revascularization and spontaneous myocardial infarction were significantly higher after PCI than after CABG.
Among patients with multivessel coronary artery disease, the rate of major adverse cardiovascular events was higher among those who had undergone PCI with the use of everolimus-eluting stents than among those who had undergone CABG. (Funded by CardioVascular Research Foundation and others; BEST ClinicalTrials.gov number, NCT00997828.).
Polymer nanocomposites offer significant potential in the development of advanced materials for numerous applications. These novel materials benefit from the synergy between filler particles and ...polymer chains that are on similar length scales and the large quantity of interfacial area relative to the volume of the material. Although enhanced properties of these materials have been demonstrated by numerous researchers, our fundamental knowledge of the "nano" effect in terms of mechanical properties is not fully developed. In this article, we discuss the important properties of three components in a general polymer nanocomposite: the polymer matrix, the nanoscale filler, and the interfacial region. We highlight theory and experimental observations from several different fields to help guide the future research and development of understanding in this critical field.
Data regarding clinical outcomes after intravascular imaging-guided percutaneous coronary intervention (PCI) for complex coronary-artery lesions, as compared with outcomes after angiography-guided ...PCI, are limited.
In this prospective, multicenter, open-label trial in South Korea, we randomly assigned patients with complex coronary-artery lesions in a 2:1 ratio to undergo either intravascular imaging-guided PCI or angiography-guided PCI. In the intravascular imaging group, the choice between intravascular ultrasonography and optical coherence tomography was at the operators' discretion. The primary end point was a composite of death from cardiac causes, target-vessel-related myocardial infarction, or clinically driven target-vessel revascularization. Safety was also assessed.
A total of 1639 patients underwent randomization, with 1092 assigned to undergo intravascular imaging-guided PCI and 547 assigned to undergo angiography-guided PCI. At a median follow-up of 2.1 years (interquartile range, 1.4 to 3.0), a primary end-point event had occurred in 76 patients (cumulative incidence, 7.7%) in the intravascular imaging group and in 60 patients (cumulative incidence, 12.3%) in the angiography group (hazard ratio, 0.64; 95% confidence interval, 0.45 to 0.89; P = 0.008). Death from cardiac causes occurred in 16 patients (cumulative incidence, 1.7%) in the intravascular imaging group and in 17 patients (cumulative incidence, 3.8%) in the angiography group; target-vessel-related myocardial infarction occurred in 38 (cumulative incidence, 3.7%) and 30 (cumulative incidence, 5.6%), respectively; and clinically driven target-vessel revascularization in 32 (cumulative incidence, 3.4%) and 25 (cumulative incidence, 5.5%), respectively. There were no apparent between-group differences in the incidence of procedure-related safety events.
Among patients with complex coronary-artery lesions, intravascular imaging-guided PCI led to a lower risk of a composite of death from cardiac causes, target-vessel-related myocardial infarction, or clinically driven target-vessel revascularization than angiography-guided PCI. (Supported by Abbott Vascular and Boston Scientific; RENOVATE-COMPLEX-PCI ClinicalTrials.gov number, NCT03381872).
Slim-panel holographic video display An, Jungkwuen; Won, Kanghee; Kim, Young ...
Nature communications,
11/2020, Volume:
11, Issue:
1
Journal Article
Peer reviewed
Open access
Since its discovery almost 70 years ago, the hologram has been considered to reproduce the most realistic three dimensional images without visual side effects. Holographic video has been extensively ...researched for commercialization, since Benton et al. at MIT Media Lab developed the first holographic video systems in 1990. However, commercially available holographic video displays have not been introduced yet for several reasons: narrow viewing angle, bulky optics and heavy computing power. Here we present an interactive slim-panel holographic video display using a steering-backlight unit and a holographic video processor to solve the above issues. The steering-backlight unit enables to expand the viewing angle by 30 times and its diffractive waveguide architecture makes a slim display form-factor. The holographic video processor computes high quality holograms in real-time on a single-chip. We suggest that the slim-panel holographic display can provide realistic three-dimensional video in office and household environments.
The association of physical activity with the development and progression of coronary artery calcium (CAC) scores has not been studied. This study aimed to evaluate the prospective association ...between physical activity and CAC scores in apparently healthy adults.
Prospective cohort study of men and women free of overt cardiovascular disease who underwent comprehensive health screening examinations between 1 March 2011 and 31 December 2017. Baseline physical activity was measured using the International Physical Activity Questionnaire Short Form (IPAQ-SF) and categorised into three groups (inactive, moderately active and health-enhancing physically active (HEPA)). The primary outcome was the difference in the 5-year change in CAC scores by physical activity category at baseline.
We analysed 25 485 participants with at least two CAC score measurements. The proportions of participants who were inactive, moderately active and HEPA were 46.8%, 38.0% and 15.2%, respectively. The estimated adjusted average baseline CAC scores (95% confidence intervals) in participants who were inactive, moderately active and HEPA were 9.45 (8.76, 10.14), 10.20 (9.40, 11.00) and 12.04 (10.81, 13.26). Compared with participants who were inactive, the estimated adjusted 5-year average increases in CAC in moderately active and HEPA participants were 3.20 (0.72, 5.69) and 8.16 (4.80, 11.53). Higher physical activity was association with faster progression of CAC scores both in participants with CAC=0 at baseline and in those with prevalent CAC.
We found a positive, graded association between physical activity and the prevalence and the progression of CAC, regardless of baseline CAC scores.
There are conflicting data regarding the benefit of intravascular ultrasound (IVUS)–guided percutaneous coronary intervention (PCI) over angiography-guided PCI. Since the last meta-analysis was ...published, several new studies have been reported. We performed a comprehensive meta-analysis to evaluate the clinical impact of IVUS-guided PCI with drug-eluting stent compared with conventional angiography-guided PCI. This meta-analysis included 26,503 patients from 3 randomized and 14 observational studies; 12,499 patients underwent IVUS-guided PCI and 14,004 underwent angiography-guided PCI. Main outcome measures were total mortality, myocardial infarction (MI), stent thrombosis, and target lesion revascularization (TLR). IVUS-guided PCI was significantly associated with more stents, longer stents, and larger stents. Regarding clinical outcomes, IVUS-guided PCI was associated with a significantly lower risk of TLR (odds ratio OR 0.81, 95% confidence interval CI 0.66 to 1.00, p = 0.046). In addition, the risk of death (OR 0.61, 95% CI 0.48 to 0.79, p <0.001), MI (OR 0.57, 95% CI 0.44 to 0.75, p <0.001), and stent thrombosis (OR 0.59, 95% CI 0.47 to 0.75, p <0.001) were also decreased. In conclusion, our meta-analysis demonstrated that IVUS-guided PCI was associated with lower risk of death, MI, TLR, and stent thrombosis after drug-eluting stent implantation.
Objectives The goal of this study was to identify clinical and lesion-specific local factors affecting visual-functional mismatch. Background Although lesion severity determined by coronary ...angiography has not been well correlated with physiological significance, the mechanism of the discordance remains poorly understood. Methods The authors assessed quantitative coronary angiography, intravascular ultrasound (IVUS), and fractional flow reserve (FFR) in a prospective cohort of 1,000 patients with 1,129 coronary lesions. Three-dimensional computational simulation studies were performed. Results Lesions with angiographic diameter stenosis (DS) ≥50% and FFR >0.80 (“mismatches”) were seen in 57% of non–left main lesions and in 35% of the left main lesions, respectively (p = 0.032). Conversely, among the lesions with DS <50% and FFR <0.80 (“reverse mismatches”) 16% were found in the non–left main lesions and 40% in the left main lesions (p < 0.001). The independent predictors for mismatch were advanced age, non–left anterior descending artery location, absence of plaque rupture, short lesion length, large minimal lumen area, smaller plaque burden, and greater minimal lumen diameter. Conversely, reverse mismatch was independently associated with younger age, left anterior descending artery location, the presence of plaque rupture, a smaller minimal lumen area, and larger plaque burden. In a computational simulation study, FFR was influenced by DS, lesion length, different lesion shape, plaque eccentricity, surface roughness, and various shapes of plaque rupture. Conclusions There were high frequencies of visual-functional mismatch between angiography and FFR. The discrepancy was related to the clinical and lesion-specific factors frequently unrecognizable by angiography, thus suggesting that coronary angiography cannot accurately predict FFR. (Natural History of FFR-Guided Deferred Coronary Lesions IRIS FFR-DEFER; NCT01366404 )
Atomically precise fabrication methods are critical for the development of next-generation technologies. For example, in nanoelectronics based on van der Waals heterostructures, where two-dimensional ...materials are stacked to form devices with nanometer thicknesses, a major challenge is patterning with atomic precision and individually addressing each molecular layer. Here we demonstrate an atomically thin graphene etch stop for patterning van der Waals heterostructures through the selective etch of two-dimensional materials with xenon difluoride gas. Graphene etch stops enable one-step patterning of sophisticated devices from heterostructures by accessing buried layers and forming one-dimensional contacts. Graphene transistors with fluorinated graphene contacts show a room temperature mobility of 40,000 cm
V
s
at carrier density of 4 × 10
cm
and contact resistivity of 80 Ω·μm. We demonstrate the versatility of graphene etch stops with three-dimensionally integrated nanoelectronics with multiple active layers and nanoelectromechanical devices with performance comparable to the state-of-the-art.