The final months of 2019 witnessed the emergence of a novel coronavirus in the human population. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has since spread across the globe and is ...posing a major burden on society. Measures taken to reduce its spread critically depend on timely and accurate identification of virus-infected individuals by the most sensitive and specific method available, i.e. real-time reverse transcriptase PCR (RT-PCR). Many commercial kits have recently become available, but their performance has not yet been independently assessed.
The aim of this study was to compare basic analytical and clinical performance of selected RT-PCR kits from seven different manufacturers (Altona Diagnostics, BGI, CerTest Biotec, KH Medical, PrimerDesign, R-Biopharm AG, and Seegene).
We used serial dilutions of viral RNA to establish PCR efficiency and estimate the 95 % limit of detection (LOD95). Furthermore, we ran a panel of SARS-CoV-2-positive clinical samples (n = 13) for a preliminary evaluation of clinical sensitivity. Finally, we used clinical samples positive for non-coronavirus respiratory viral infections (n = 6) and a panel of RNA from related human coronaviruses to evaluate assay specificity.
PCR efficiency was ≥96 % for all assays and the estimated LOD95 varied within a 6-fold range. Using clinical samples, we observed some variations in detection rate between kits. Importantly, none of the assays showed cross-reactivity with other respiratory (corona)viruses, except as expected for the SARS-CoV-1 E-gene.
We conclude that all RT-PCR kits assessed in this study may be used for routine diagnostics of COVID-19 in patients by experienced molecular diagnostic laboratories.
Wastewater surveillance has shown to be a valuable and efficient tool to obtain information about the trends of COVID-19 in the community. Since the recent emergence of new variants, associated with ...increased transmissibility and/or antibody escape (variants of concern), there is an urgent need for methods that enable specific and timely detection and quantification of the occurrence of these variants in the community. In this study, we demonstrate the use of RT-ddPCR on wastewater samples for specific detection of mutation N501Y. This assay enabled simultaneous enumeration of lineage B.1.351 (containing the 501Y mutation) and Wild Type (WT, containing 501N) SARS-CoV-2 RNA. Detection of N501Y was possible in samples with mixtures of WT with low proportions of B.1.351 (0.5%) and could accurately determine the proportion of N501Y and WT in mixtures of SARS-CoV-2 RNA. The application to raw sewage samples from the cities of Amsterdam and Utrecht demonstrated that this method can be applied to wastewater samples. The emergence of N501Y in Amsterdam and Utrecht wastewater aligned with the emergence of B.1.1.7 as causative agent of COVID-19 in the Netherlands, indicating that RT-ddPCR of wastewater samples can be used to monitor the emergence of the N501Y mutation in the community. It also indicates that RT-ddPCR could be used for sensitive and accurate monitoring of current (like K417N, K417T, E484K, L452R) or future mutations present in SARS-CoV-2 variants of concern. Monitoring these mutations can be used to obtain insight in the introduction and spread of VOC and support public health decision-making regarding measures to limit viral spread or allocation of testing or vaccination.
Display omitted
•RT-ddPCR can identify low proportions (0.5%) of N501Y.•Emergence of N501Y in wastewater aligned with B.1.1.7 emergence in patients.•Rapid and accurate monitoring of current and future VoC signature mutations in wastewater is feasible.•Monitoring VoC in sewage can be used to support health decision-making.
The ongoing outbreak of the recently emerged novel coronavirus (2019-nCoV) poses a challenge for public health laboratories as virus isolates are unavailable while there is growing evidence that the ...outbreak is more widespread than initially thought, and international spread through travellers does already occur.
We aimed to develop and deploy robust diagnostic methodology for use in public health laboratory settings without having virus material available.
Here we present a validated diagnostic workflow for 2019-nCoV, its design relying on close genetic relatedness of 2019-nCoV with SARS coronavirus, making use of synthetic nucleic acid technology.
The workflow reliably detects 2019-nCoV, and further discriminates 2019-nCoV from SARS-CoV. Through coordination between academic and public laboratories, we confirmed assay exclusivity based on 297 original clinical specimens containing a full spectrum of human respiratory viruses. Control material is made available through European Virus Archive - Global (EVAg), a European Union infrastructure project.
The present study demonstrates the enormous response capacity achieved through coordination of academic and public laboratories in national and European research networks.
Rapid detection of infection is essential for stopping the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The Roche SD Biosensor rapid antigen test for SARS-CoV-2 was ...evaluated in a nonhospitalized symptomatic population. We rapid-tested a sample onsite and compared results with those from reverse transcription PCR and virus culture. We analyzed date of onset and symptoms using data from a clinical questionnaire. Overall test sensitivity was 84.9% (95% CI 79.1-89.4) and specificity was 99.5% (95% CI 98.7-99.8). Sensitivity increased to 95.8% (95% CI 90.5-98.2) for persons who sought care within 7 days of symptom onset. Test band intensity and time to result correlated strongly with viral load; thus, strong positive results could be read before the recommended time. Approximately 98% of all viable specimens with cycle threshold <30 were detected. Rapid antigen tests can detect symptomatic SARS-CoV-2 infections in the early phase of disease, thereby identifying the most infectious persons.
•Commercial SARS-CoV-2 RT-PCR analytical performance comparison.•Analytical sensitivity of 13 SARS-CoV-2 RT-PCRs varied between 3.3–330 RNA copies.•All but 1 assay had sensitivity within one order of ...magnitude of the reference assay.•Only 1 assay cross reacted with another coronavirus (MERS).
The emergence of a new coronavirus in Wuhan China has triggered a global need for accurate diagnostic assays. Initially, mostly laboratory developed molecular tests were available but shortly thereafter different commercial assays started to appear and are still increasing in number. Although independent performance evaluations are ongoing, available data is still scarce. Here we provide a direct comparison of key performance characteristics of 13 commercial RT-PCR assays. Thirteen RT-PCR assays were selected based on the criteria that they can be used following generic RNA extraction protocols, on common PCR platforms and availability. Using a 10-fold and 2-fold dilution series of a quantified SARS-CoV-2 cell-cultured virus stock, performance was assessed compared to our in house validated assay. Specificity was tested by using RNA extracted from cultured common human coronaviruses. All RT-PCR kits included in this study exhibited PCR efficiencies > 90%, except for the Sentinel Diagnostics B E-gene RUO assay (80%). Analytical sensitivity varied between 3.3 RNA copies to 330 RNA copies. Only one assay cross reacted with another human coronavirus (MERS). This study provides a technical baseline of 13 different commercial PCR assays for SARS-CoV-2 detection that can be used by laboratories interested in purchasing any of these for further full clinical validation.
Summary Background miR-122 is an important host factor for hepatitis C virus (HCV) replication. The aim of this study was to assess the safety and tolerability, pharmacokinetics, and antiviral effect ...of a single dose of RG-101, a hepatocyte targeted N-acetylgalactosamine conjugated oligonucleotide that antagonises miR-122, in patients with chronic HCV infection with various genotypes. Methods In this randomised, double-blind, placebo-controlled, multicentre, phase 1B study, patients were randomly assigned to RG-101 or placebo (7:1). We enrolled men and postmenopausal or hysterectomised women (aged 18–65 years) with chronic HCV genotype 1, 3, or 4 infection diagnosed at least 24 weeks before screening who were either treatment naive to or relapsed after interferon-α based therapy. Patients with co-infection (hepatitis B virus or HIV infection), evidence of decompensated liver disease, or a history of hepatocellular carcinoma were excluded. Randomisation was done by an independent, unblinded, statistician using the SAS procedure Proc Plan. The first cohort received one subcutaneous injection of 2 mg/kg RG-101 or placebo; the second cohort received one subcutaneous injection of 4 mg/kg or placebo. Patients were followed up for 8 weeks (all patients) and up to 76 weeks (patients with no viral rebound and excluding those who were randomised to the placebo group) after randomisation. The primary objective was safety and tolerability of RG-101. This trial was registered with EudraCT, number 2013-002978-49. Findings Between June 4, 2014, and Oct 27, 2014, we enrolled 32 patients with chronic HCV genotype 1 (n=16), 3 (n=10), or 4 (n=6) infections. In the first cohort, 14 patients were randomly assigned to receive 2 mg/kg RG-101 and two patients were randomly assigned to receive placebo, and in the second cohort, 14 patients were randomly assigned to receive 4 mg/kg RG-101 and two patients were randomly assigned to receive placebo. Overall, 26 of the 28 patients dosed with RG-101 reported at least one treatment-related adverse event. At week 4, the median viral load reduction from baseline was 4·42 (IQR 3·23–5·00) and 5·07 (4·19–5·35) log10 IU/mL in patients dosed with 2 mg/kg RG-101 or 4 mg/kg RG-101. Three patients had undetectable HCV RNA levels 76 weeks after a single dose of RG-101. Viral rebound at or before week 12 was associated with the appearance of resistance associated substitutions in miR-122 binding regions in the 5′ UTR of the HCV genome. Interpretation This study showed that one administration of 2 mg/kg or 4 mg/kg RG-101, a hepatocyte targeted N-acetylgalactosamine conjugated anti-miR-122 oligonucleotide, was well tolerated and resulted in substantial viral load reduction in all treated patients within 4 weeks, and sustained virological response in three patients for 76 weeks. Funding Regulus Therapeutics, Inc.
In this paper, deep learning is coupled with explainable artificial intelligence techniques for the discovery of representative genomic sequences in SARS-CoV-2. A convolutional neural network ...classifier is first trained on 553 sequences from the National Genomics Data Center repository, separating the genome of different virus strains from the Coronavirus family with 98.73% accuracy. The network's behavior is then analyzed, to discover sequences used by the model to identify SARS-CoV-2, ultimately uncovering sequences exclusive to it. The discovered sequences are validated on samples from the National Center for Biotechnology Information and Global Initiative on Sharing All Influenza Data repositories, and are proven to be able to separate SARS-CoV-2 from different virus strains with near-perfect accuracy. Next, one of the sequences is selected to generate a primer set, and tested against other state-of-the-art primer sets, obtaining competitive results. Finally, the primer is synthesized and tested on patient samples (n = 6 previously tested positive), delivering a sensitivity similar to routine diagnostic methods, and 100% specificity. The proposed methodology has a substantial added value over existing methods, as it is able to both automatically identify promising primer sets for a virus from a limited amount of data, and deliver effective results in a minimal amount of time. Considering the possibility of future pandemics, these characteristics are invaluable to promptly create specific detection methods for diagnostics.
To examine the diagnostic performance of real-time reverse transcription (RT)-polymerase chain reaction (PCR) assays for Zika virus detection.
We compared seven published real-time RT-PCR assays and ...two new assays that we have developed. To determine the analytical sensitivity of each assay, we constructed a synthetic universal control ribonucleic acid (uncRNA) containing all of the assays' target regions on one RNA strand and spiked human blood or urine with known quantities of African or Asian Zika virus strains. Viral loads in 33 samples from Zika virus-infected patients were determined by using one of the new assays.
Oligonucleotides of the published real-time RT-PCR assays, showed up to 10 potential mismatches with the Asian lineage causing the current outbreak, compared with 0 to 4 mismatches for the new assays. The 95% lower detection limit of the seven most sensitive assays ranged from 2.1 to 12.1 uncRNA copies/reaction. Two assays had lower sensitivities of 17.0 and 1373.3 uncRNA copies/reaction and showed a similar sensitivity when using spiked samples. The mean viral loads in samples from Zika virus-infected patients were 5 × 10
RNA copies/mL of blood and 2 × 10
RNA copies/mL of urine.
We provide reagents and updated protocols for Zika virus detection suitable for the current outbreak strains. Some published assays might be unsuitable for Zika virus detection, due to the limited sensitivity and potential incompatibility with some strains. Viral concentrations in the clinical samples were close to the technical detection limit, suggesting that the use of insensitive assays will cause false-negative results.
Performance of the SD Biosensor saliva antigen rapid test was evaluated at a large designated testing site in non-hospitalized patients, with or without symptoms.
All eligible people over 18 years of ...age presenting for a booked appointment at the designated SARS-CoV-2 testing site were approached for inclusion and enrolled following verbal informed consent. One nasopharyngeal swab was taken to carry out the default antigen rapid test from which the results were reported back to the patient and one saliva sample was self-taken according to verbal instruction on site. This was used for the saliva antigen rapid test, the RT-PCR and for virus culture. Sensitivity of the saliva antigen rapid test was analyzed in two ways: i, compared to saliva RT-PCR; and ii, compared to virus culture of the saliva samples. Study participants were also asked to fill in a short questionnaire stating age, sex, date of symptom onset. Recommended time of ≥30mins since last meal, drink or cigarette if applicable was also recorded. The study was carried out in February-March 2021 for 4 weeks.
We could include 789 people with complete records and results. Compared to saliva RT-PCR, overall sensitivity and specificity of the saliva antigen rapid test was 66.1% and 99.6% which increased to 88.6% with Ct ≤30 cutoff. Analysis by days post onset did not result in higher sensitivities because the large majority of people were in the very early phase of disease ie <3 days post onset. When breaking down the data for symptomatic and asymptomatic individuals, sensitivity ranged from 69.2% to 50% respectively, however the total number of RT-PCR positive asymptomatic participants was very low (n = 5). Importantly, almost all culture positive samples were detected by the rapid test.
Overall, the potential benefits of saliva antigen rapid test, could outweigh the lower sensitivity compared to nasopharyngeal antigen rapid test in a comprehensive testing strategy, especially for home/self-testing and in vulnerable populations like elderly, disabled or children where in intrusive testing is either not possible or causes unnecessary stress.