Abstract Kinetic information during human gait can be estimated with inverse dynamics, which is based on anthropometric, kinematic, and ground reaction data. While collecting ground reaction data ...with a force plate is useful, it is costly and requires regulated space. The goal of this study was to propose a new, accurate methodology for predicting ground reaction forces (GRFs) during level walking without the help of a force plate. To predict GRFs without a force plate, the traditional method of Newtonian mechanics was used for the single support phase. In addition, an artificial neural network (ANN) model was applied for the double support phase to solve statically indeterminate structure problems. The input variables of the ANN model, which were selected to have both dependency and independency, were limited to the trajectory, velocity, and acceleration of the whole segment's mass centre to minimise errors. The predicted GRFs were validated with actual GRFs through a ten-fold cross-validation method, and the correlation coefficients ( R ) for the ground forces were 0.918 in the medial–lateral axis, 0.985 in the anterior–posterior axis, and 0.991 in the vertical axis during gait. The ground moments were 0.987 in the sagittal plane, 0.841 in the frontal plane, and 0.868 in the transverse plane during gait. The high correlation coefficients( R ) are due to the improvement of the prediction rate in the double support phase. This study also proved the possibility of calculating joint forces and moments based on the GRFs predicted with the proposed new hybrid method. Data generated with the proposed method may thus be used instead of raw GRF data in gait analysis and in calculating joint dynamic data using inverse dynamics.
A biomechanical understanding of gait stability is needed to reduce falling risk. As a typical parameter, the COM-COP (center of mass-center of pressure) inclination angle (IA) could provide valuable ...insight into postural control and balance recovery ability. In this study, an artificial neural network (ANN) model was developed to estimate COM-COP IA based on signals using an inertial sensor. Also, we evaluated how different types of ANN and the cutoff frequency of the low-pass filter applied to input signals could affect the accuracy of the model. An inertial measurement unit (IMU) including an accelerometer, gyroscope, and magnetometer sensors was fabricated as a prototype. The COM-COP IA was calculated using a 3D motion analysis system including force plates. In order to predict the COM-COP IA, a feed-forward ANN and long-short term memory (LSTM) network was developed. As a result, the feed-forward ANN showed a relative root-mean-square error (rRMSE) of 15% while the LSTM showed an improved accuracy of 9% rRMSE. Additionally, the LSTM displayed a stable accuracy regardless of the cutoff frequency of the filter applied to the input signals. This study showed that estimating the COM-COP IA was possible with a cheap inertial sensor system. Furthermore, the neural network models in this study can be implemented in systems to monitor the balancing ability of the elderly or patients with impaired balancing ability.
Whole-body center of gravity (CG) movements in relation to the center of pressure (COP) offer insights into the balance control strategies of the human body. Existing CG measurement methods using ...expensive measurement equipment fixed in a laboratory environment are not intended for continuous monitoring. The development of wireless sensing technology makes it possible to expand the measurement in daily life. The insole system is a wearable device that can evaluate human balance ability by measuring pressure distribution on the ground. In this study, a novel protocol (data preparation and model training) for estimating the 3-axis CG trajectory from vertical plantar pressures was proposed and its performance was evaluated. Input and target data were obtained through gait experiments conducted on 15 adult and 15 elderly males using a self-made insole prototype and optical motion capture system. One gait cycle was divided into four semantic phases. Features specified for each phase were extracted and the CG trajectory was predicted using a bi-directional long short-term memory (Bi-LSTM) network. The performance of the proposed CG prediction model was evaluated by a comparative study with four prediction models having no gait phase segmentation. The CG trajectory calculated with the optoelectronic system was used as a golden standard. The relative root mean square error of the proposed model on the 3-axis of anterior/posterior, medial/lateral, and proximal/distal showed the best prediction performance, with 2.12%, 12.97%, and 12.47%. Biomechanical analysis of two healthy male groups was conducted. A statistically significant difference between CG trajectories of the two groups was shown in the proposed model. Large CG sway of the medial/lateral axis trajectory and CG fall of the proximal/distal axis trajectory is shown in the old group. The protocol proposed in this study is a basic step to have gait analysis in daily life. It is expected to be utilized as a key element for clinical applications.
Proactively detecting falls and preventing injuries are among the primary keys to a healthy life for the elderly. Near-fall remote monitoring in daily life could provide key information to prevent ...future falls and obtain quantitative rehabilitation status for patients with weak balance ability. In this study, we developed a deep learning-based novel classification algorithm to precisely categorize three classes (falls, near-falls, and activities of daily living (ADLs)) using a single inertial measurement unit (IMU) device attached to the waist. A total of 34 young participants were included in this study. An IMU containing accelerometer and gyroscope sensors was fabricated to acquire acceleration and angular velocity signals. A comprehensive experiment including thirty-six types of activities (10 types of falls, 10 types of near-falls, and 16 types of ADLs) was designed based on previous studies. A modified directed acyclic graph-convolution neural network (DAG-CNN) architecture with hyperparameter optimization was proposed to predict fall, near-fall, and ADLs. Prediction results of the modified DAG-CNN structure were found to be approximately 7% more accurate than the traditional CNN structure. For the case of near-falls, the modified DAG-CNN demonstrated excellent prediction performance with accuracy of over 98% by combining gyroscope and accelerometer features. Additionally, by combining acceleration and angular velocity the trained model showed better performance than each model of acceleration and angular velocity. It is believed that information to preemptively handle the risk of falls and quantitatively evaluate the rehabilitation status of the elderly with weak balance will be provided by monitoring near-falls.
Pre-impact fall detection can detect a fall before a body segment hits the ground. When it is integrated with a protective system, it can directly prevent an injury due to hitting the ground. An ...impact acceleration peak magnitude is one of key measurement factors that can affect the severity of an injury. It can be used as a design parameter for wearable protective devices to prevent injuries. In our study, a novel method is proposed to predict an impact acceleration magnitude after loss of balance using a single inertial measurement unit (IMU) sensor and a sequential-based deep learning model. Twenty-four healthy participants participated in this study for fall experiments. Each participant worn a single IMU sensor on the waist to collect tri-axial accelerometer and angular velocity data. A deep learning method, bi-directional long short-term memory (LSTM) regression, is applied to predict a fall's impact acceleration magnitude prior to fall impact (a fall in five directions). To improve prediction performance, a data augmentation technique with increment of dataset is applied. Our proposed model showed a mean absolute percentage error (MAPE) of 6.69 ± 0.33% with r value of 0.93 when all three different types of data augmentation techniques are applied. Additionally, there was a significant reduction of MAPE by 45.2% when the number of training datasets was increased by 4-fold. These results show that impact acceleration magnitude can be used as an activation parameter for fall prevention such as in a wearable airbag system by optimizing deployment process to minimize fall injury in real time.
Center of pressure (COP) trajectories of human can maintain regulation of forward progression and stability of lateral sway during walking. The insole pressure system can only detect COP trajectories ...of each foot during single stance. In this study, we developed artificial neural network models that could present COP trajectories in an integrated coordinate system during a complete gait cycle using pressure information of the insole system. A feed forward artificial neural network (FFANN) and a long short-term memory (LSTM) model were developed. For FFANN, among 198 pressure sensors from Pedar-X insoles, proper input variables were selected using sequential forward selection to reduce input dimension. The LSTM model used all 198 signals as inputs because of its self-learning characteristic. As results of cross-validation, the FFANN model showed correlation coefficients of 0.98–0.99 and 0.93–0.95 in anterior/posterior and medial/lateral directions, respectively. For the LSTM model, correlation coefficients were similar to those of FFANN. However, the relative root mean square error (12.5%) of the FFANN model was higher than that (9.8%) of the LSTM model in medial/lateral direction (
p
= 0.03). This study can be used for quantitative evaluation of clinical diagnosis and rehabilitation status for patient with various diseases through further training using varied databases.
Graphical abstract
Architectures of neural networks developed in this study (a feed forward artificial neural network;
b
LSTM network)
Balanced posture without dizziness is achieved via harmonious coordination of visual, vestibular, and somatosensory systems. Specific frequency bands of center of pressure (COP) signals during quiet ...standing are closely related to the sensory inputs of the sensorimotor system. In this study, we proposed a deep learning-based novel protocol using the COP signal frequencies to estimate the equilibrium score (ES), a sensory system contribution. Sensory organization test was performed with normal controls (n=125), patients with Meniere's disease (n=72) and vestibular neuritis (n=105). The COP signals preprocessed via filtering, detrending and augmenting during quiet standing were converted to frequency domains utilizing Short-time Fourier Transform. Four different types of CNN backbone including GoogleNet, ResNet-18, SqueezeNet, and VGG16 were trained and tested using the frequency transformed data of COP and the ES under conditions #2 to #6. Additionally, the 100 original output classes (1 to 100 ESs) were encoded into 50, 20, 10 and 5 sub-classes to improve the performance of the prediction model. Absolute difference between the measured and predicted ES was about 1.7 (ResNet-18 with encoding of 20 sub-classes). The average error of each sensory analysis calculated using the measured ES and predicted ES was approximately 1.0%. The results suggest that the sensory system contribution of patients with dizziness can be quantitatively assessed using only the COP signal from a single test of standing posture. This study has potential to reduce balance testing time (spent on six conditions with three trials each in sensory organization test) and the size of computerized dynamic posturography (movable visual surround and force plate), and helps achieve the widespread application of the balance assessment.
Biomechanical understanding of the knee joint during a golf swing is essential to improve performance and prevent injury. In this study, we quantified the flexion/extension angle and moment as the ...primary knee movement, and evaluated quasi-stiffness represented by moment-angle coupling in the knee joint. Eighteen skilled and 23 unskilled golfers participated in this study. Six infrared cameras and two force platforms were used to record a swing motion. The anatomical angle and moment were calculated from kinematic and kinetic models, and quasi-stiffness of the knee joint was determined as an instantaneous slope of moment-angle curves. The lead knee of the skilled group had decreased resistance duration compared with the unskilled group (P < 0.05), and the resistance duration of the lead knee was lower than that of the trail knee in the skilled group (P < 0.01). The lead knee of the skilled golfers had greater flexible excursion duration than the trail knee of the skilled golfers, and of both the lead and trail knees of the unskilled golfers. These results provide critical information for preventing knee injuries during a golf swing and developing rehabilitation strategies following surgery.
One important technique of surgical navigation is surface registration that matches coordinates in two different spaces. We proposed a novel method to extract an optimal point cloud in image space ...corresponding to the point cloud in patient space to improve the registration accuracy. In the hemispherical study, our proposed method demonstrated a reduced surface registration error (SRE) and target registration error (TRE) compared to the conventional method in all cases (number of points, distribution, noise). In the phantom study, the SRE and TRE were low and stable in the proposed method, with SRE reduced by 22 % and TRE by 18 % (p < 0.05). The proposed method was not affected by the number of points, distribution, or noise in the point cloud, and it could improve the registration accuracy without the aid of additional equipment.