Purpose
The goal of this work was to evaluate toxicity and local control following hypofractionated stereotactic radiation treatment with special focus on changes in tumor volume and hearing ...capacity.
Patients and methods
In all, 29 patients with unilateral acoustic neuroma were treated between 2001 and 2007 within a prospective radiation protocol (7 × 4 Gy ICRU dose). Median tumor volume was 0.9 ml. Follow-up started at 6 months and was repeated annually with MRI volumetry and audiometry. Hearing preservation was defined as preservation of Class A/B hearing according to the guidelines of the American Academy of Otolaryngology (1995).
Results
No patient had any intervention after a median imaging follow-up of 89.5 months, one patient showed radiological progression. Transient increase of tumor volume developed in 17/29 patients, whereas 22/29 patients (75.9 %) presented with a volume reduction at last follow-up. A total of 21 patients were eligible for hearing evaluation. Mean pure tone average (PTA) deteriorated from 39.3 to 65.9 dB and mean speech discrimination score (SDS) dropped from 74.3 to 38.1 %. The 5-year actuarial Class A/B hearing preservation rate was 50.0 ± 14.4 %.
Conclusion
Radiation increases only minimally, if at all, the hearing deterioration which emerges by observation alone. Presbyacusis is not responsible for this deterioration. Transient tumor enlargement is common. Today radiation of small- and medium-sized acoustic neuroma can be performed with different highly conformal techniques as fractionated treatment or single low-dose radiosurgery with equal results regarding tumor control, hearing preservation, and side effects. Hypofractionation is more comfortable for the patient than conventional regimens and represents a serious alternative to frameless radiosurgery.
Our purpose was to investigate the tolerability of accelerated, twice-daily, high-dose radiotherapy. The secondary endpoints were survival and locoregional tumor control.
Thirty consecutive patients ...with histologically/cytologically proven non-small-cell lung cancer were enrolled. Tumor Stage I, II, IIIA, and IIIB was found in 7, 3, 12, and 8 patients, respectively. We applied a median of 84.6 Gy (range, 75.6-90.0 Gy) to the primary tumors, 63.0 Gy (range, 59.4-72.0 Gy) to lymph nodes, and 45 Gy to nodes electively (within a region of about 6 cm cranial to macroscopically involved sites). Fractional doses of 1.8 Gy twice daily, with an interval of 11 hours, were given, resulting in a median treatment time of 35 days. In the majority of patients the conformal target-splitting technique was used. In 19 patients (63%) two cycles of induction chemotherapy were given. The median follow-up time of survivors is 72 months (range, 62-74 months).
We found Grade 1, 2 and 3 acute esophageal toxicity in 11 patients (37%), 2 patients (7%), and 2 patients (7%), respectively. Grade 2 acute pneumonitis was seen in 2 patients (7%). No late toxicity greater than Grade 1 was observed. The actual overall survival rates at 2 and 5 years are 63% and 23%, respectively; the median overall survival, 27.7 months. In 9 patients a local failure occurred, 7 of them presenting initially with an atelectasis without availability of 18-fluorodeoxyglucose-positron emission tomography staging at that time. In 4 patients recurrence occurred regionally.
This Phase I/II trial with long-term follow-up shows low toxicity with promising results for survival and locoregional tumor control.
Background and Purpose:
In this study, a new method is introduced, which allows the overlay of three-dimensional structures, that have been delineated on transverse slices, onto the fluoroscopy from ...conventional simulators in real time.
Patients and Methods:
Setup deviations between volumetric imaging and simulation were visualized, measured and corrected for 701 patient isocenters.
Results:
Comparing the accuracy to mere virtual simulation lacking additional X-ray imaging, a clear benefit of the new method could be shown. On average, virtual prostate simulations had to be corrected by 0.48 cm (standard deviation SD 0.38), and those of the breast by 0.67 cm (SD 0.66).
Conclusion:
The presented method provides an easy way to determine entity-specific safety margins related to patient setup errors upon registration of bony anatomy (prostate 0.9 cm for 90% of cases, breast 1.3 cm). The important role of planar X-ray imaging was clearly demonstrated. The innovation can also be applied to adaptive image-guided radiotherapy (IGRT) protocols.