The aim of this study was to improve reinforcement learning algorithm by combining artificial bee colony algorithm. The traditional method of reinforcement learning algorithm has a very low ...convergence rate due to random choices. An ant algorithm will help to make random choices in reinforcement learning more appropriate. This hybrid algorithm called the bee colony reinforcement (BCR) algorithm. The tip of the arm must reach a predetermined purpose by BCR algorithm. The results show that the BCR algorithm in the model has been able to reduce the time to reach the goal than the reinforcement learning algorithm (In average 12 steps faster). Also, the path for reaching the goal in the BCR algorithm was far more direct and shorter than the reinforcement learning algorithm. This method also detects the optimal path towards the goal.
High-intensity focused ultrasound induces focalized tissue coagulation by increasing the tissue temperature in a tight focal region. Several methods have been proposed to monitor high-intensity ...focused ultrasound-induced thermal lesions. Currently, ultrasound imaging techniques that are clinically used for monitoring high-intensity focused ultrasound treatment are standard pulse-echo B-mode ultrasound imaging, ultrasound temperature estimation, and elastography-based methods. On the contrary, the efficacy of two-dimensional Nakagami parametric imaging based on the distribution of the ultrasound backscattered signals to quantify properties of soft tissue has recently been evaluated. In this study, ultrasound radio frequency echo signals from ex vivo tissue samples were acquired before and after high-intensity focused ultrasound exposures and then their Nakagami parameter and scaling parameter of Nakagami distribution were estimated. These parameters were used to detect high-intensity focused ultrasound-induced thermal lesions. Also, the effects of changing the acoustic power of the high-intensity focused ultrasound transducer on the Nakagami parameters were studied. The results obtained suggest that the Nakagami distribution's scaling and Nakagami parameters can effectively be used to detect high-intensity focused ultrasound-induced thermal lesions in tissue ex vivo. These parameters can also be used to understand the degree of change in tissue caused by high-intensity focused ultrasound exposures, which could be interpreted as a measure of degree of variability in scatterer concentration in various parts of the high-intensity focused ultrasound lesion.
Background: Nonlinear dynamics, especially the chaos characteristics, are useful in analyzing bio-potentials with many complexities. In this study, the evaluation of arm-tip force estimation method ...from the electroencephalography (EEG) signal in the vertical plane has been studied and chaos characteristics, including fractal dimension, Lyapunov exponent, entropy, and correlation dimension characteristics of EEG signals have been measured and analyzed at different levels of forces. Method: Electromyography signal was recorded with the help of the BIOPEC device (the Mp-100 model) and from the forearm muscle with surface electrodes, and the EEG signals were recorded from five major motor-related cortical areas according to 10-20 standard three times in a normal healthy 33-year-old male, athlete and right handed simultaneously with importing a force to 10 sinkers weighing from 10 to 100 Newton with step 10 Newton. Results: The findings confirm that force estimation through EEG signals is feasible, especially using fractal dimension feature. The R-squared values for Fractal dimension, Lyapunov exponent, and entropy and correlation dimension features for linear trend line were 0.93, 0.7, 0.86, and 0.41, respectively. Conclusion: The linear increase of characteristics especially fractal dimension and entropy, together with the results from other EEG and neuroimaging studies, suggests that under normal conditions, brain recruits motor neurons at a linear progress when increasing the force.
Background: As people get older, muscles become more synchronized and cooperate to accomplish an activity, so the main purpose of this research is to determine the relationship between changes in age ...and the amount of muscle synergy. The presence of muscle synergies has been long considered in the movement control as a mechanism for reducing the degree of freedom of the motor system. Methods: By combining these synergies, a wide range of complex movements can be produced. Muscle synergies are often extracted from the electromyogram (EMG) signal. One of the most common methods for extracting synergies is the nonnegative matrix factorization. In this research, the EMG signal is obtained from individuals from different age groups (namely 15-20 years, 25-30 years, and 35-40 years), and after preprocessing, the muscular synergies are extracted. By processing and studying these synergies. Results: It was observed that there is a significant difference between the muscular synergy of different age groups. Furthermore, there was a significant difference in the mean value of synergy coefficients in each group, especially in motions that were accompanied by force. Conclusion: This result candidates this parameter as a biomarker to differentiate and recognize the effects of age on the individual's muscular signal. In the best case, using the synergy tool, classification of the age of persons can be done by 77%.
Background: During the past few decades, high-intensity focused ultrasound (HIFU) modality has been gaining surging interest in various therapeutic applications such as non- or minimally-invasive ...cancer treatment. Among other attributes, robust and real-time HIFU treatment monitoring and lesion detection have become essential issues for successful clinical acceptance of the modality. More recently, ultrasound radio frequency (RF) time series imaging has been studied by a number of researchers. Materials and Methods: The objective of this study is to investigate the applicability of entropy parameter of RF time series of ultrasound backscattered signals, a. k. a. Entropy imaging, toward HIFU thermal lesion detection. To this end, five fresh ex vivo porcine muscle tissue samples were exposed to HIFU exposures with total acoustic powers ranging from 30 to 110 Watts. The contrast-to-speckle ratio (CSR) values of the entropy images and their corresponding B-mode images of pre-, during- and post-HIFU exposure for each acoustic power were calculated. Results: The novelty of this study is the use of Entropy parameter on ultrasound RF time series for the first time. Statistically significant differences were obtained between the CSR values for the B mode and entropy images at various acoustic powers. In case of 110 Watt, a CSR value 3.4 times higher than B-mode images was accomplished using the proposed method. Furthermore, the proposed method is compared with the scaling parameter of Nakagami imaging and same data which are used in this study. Conclusion: Entropy has the potential for using as an imaging parameter for differentiating lesions in HIFU surgery.
High-intensity focused ultrasound (HIFU) is a novel treatment modality used by scientists and clinicians in the recent decades. This modality has had a great and significant success as a noninvasive ...surgery technique applicable in tissue ablation therapy and cancer treatment. In this study, radio frequency (RF) ultrasound signals were acquired and registered in three stages of before, during, and after HIFU exposures. Different features of RF time series signals including the sum of amplitude spectrum in the four quarters of the frequency range, the slope, and intercept of the best-fit line to the entire power spectrum and the Shannon entropy were utilized to distinguish between the HIFU-induced thermal lesion and the normal tissue. We also examined the RF data, frame by frame to identify exposure effects on the formation and characteristics of a HIFU thermal lesion at different time steps throughout the treatment. The results obtained showed that the spectrum frequency quarters and the slope and intercept of the best fit line to the entire power spectrum both increased two times during the HIFU exposures. The Shannon entropy, however, decreased after the exposures. In conclusion, different characteristics of RF time series signal possess promising features that can be used to characterize ablated and nonablated tissues and to distinguish them from each other in a quasi-quantitative fashion.
According to the top priority of health and fitness, the ultrasound (US) technique for measuring subcutaneous adipose tissue (SAT), as an indicator for body composition analysis, has received the ...most attention. So, tissue segmentation was performed to determine the boundaries between skin, SAT, and muscle in phantoms with different layers, and thicknesses that were fabricated to simulate tissue layers. The pre-processing of the signal was carried out using wavelet transform (WT) and Hilbert transform for denoising and detection. After the processing step, using WT for signal decomposition, a neural network was trained based on the scan line signals to detect the SAT layer. The coordinates of the convex probe were converted to linear to reduce the time and increase the accuracy for creating the target matrix. The algorithm was designed for automatic measurements of deep (normal), superficial (random), and noisy SAT thickness. Statistical evaluation was done to assess the system's skill in tissue classification and measurement of SAT thickness. Results revealed that most of the features related to coarse levels of detail coefficients extracted from wavelet decomposition levels can be used to build a classifier that can be applied successfully to differentiate between SAT and non-SAT tissue regions with a mean classification accuracy of 94.3% for 20 mm and 92.4% for 4 mm SAT in random mode with the error of estimate 0.05% and 0.07% respectively. Also, using 3 median filters and increasing their lengths from 3 to 7 improved the accuracy results to find SAT entry and exit boundaries.
In this work, the use of magnetic induction (MI) to cross the air-water boundary is investigated. An analytical expression is derived for the magnetic field in air from a coil underwater and is ...validated with simulation results that also include the effect of the front-end. Specifically, the ratio of the induced voltage of the receiver over transmitter current is maximized for a given distance between small coils with a radius of 6.5 cm and it is found that an optimal frequency exists: for a distance between 10 and 100 m, the optimum frequency of operation decreases from 8000 down to 80 Hz. Experiments are performed in air and in sea-water tanks to verify the mutual inductance and end-to-end attenuation. The experiments agree with the theory for distances up to 1.6 m, after which a noise floor is reached. To increase the range, the use of passive repeaters is studied and a relay coil that transfers the energy to a receiver inside a magnetic shield is analyzed. When configured correctly, this relay can significantly enhance the receiver output voltage, as demonstrated through simulations, potentially increasing it by up to tenfold.