We report results of a search for light (≲10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons ...corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections σ(n)>7×10(-42) cm(2), for a dark matter particle mass m(χ)=7 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber to search for dark matter weakly interacting massive particles (WIMPs). The detector ...measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon to discriminate signal from background down to 4.5 keV nuclear-recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006, and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross section of 8.8x10(-44) cm2 for a WIMP mass of 100 GeV/c2, and 4.5x10(-44) cm2 for a WIMP mass of 30 GeV/c2. This result further constrains predictions of supersymmetric models.
The XENON100 dark matter experiment Aprile, E.; Arisaka, K.; Arneodo, F. ...
Astroparticle physics,
April 2012, 2012-4-00, 20120401, Volume:
35, Issue:
9
Journal Article
Peer reviewed
Open access
► XENON100 is currently one of the most sensitive experiments to detect WIMP dark matter. ► Detector design and active/passive shielding reduce the radioactive background level. ► The event vertex of ...an interaction is reconstructed with a few mm precision. ► All position dependent signal corrections are presented in the paper. ► An energy scale exploiting the light-charge anti-correlation leads to an energy resolution competitive with NaI(Tl) crystals.
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs.
The active target of XENON100 contains 62kg of LXe, surrounded by an LXe veto of 99kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in xenon gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield and is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy. The experiment has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of σ=2×10−45cm2 for a 100GeV/c2 WIMP.
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter weakly interacting massive particles (WIMPs) scattering off 62 kg of ...liquid xenon in an ultralow background dual-phase time projection chamber. In this Letter, we present first dark matter results from the analysis of 11.17 live days of nonblind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the predefined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross sections above 3.4 × 10⁻⁴⁴ cm² for 55 GeV/c² WIMPs at 90% confidence level. Below 20 GeV/c², this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14
kg, was installed ...at the Gran Sasso Underground Laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulation data. The results on the detector’s energy threshold, position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10
keVr) and low background rate achieved.
XENON10 is an experiment to directly detect weakly interacting massive particles (WIMPs), which may comprise the bulk of the nonbaryonic dark matter in our Universe. We report new results for ...spin-dependent WIMP-nucleon interactions with 129Xe and 131Xe from 58.6 live days of operation at the Laboratori Nazionali del Gran Sasso. Based on the nonobservation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of approximately 10 GeV/c2-2 TeV/c2 as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
► Material selection based on their intrinsic radioactive contaminations is crucial for low background experiments. ► We present detailed results from the material screening and selection campaign ...for the XENON100 dark matter experiment. ► The measurements were performed using low background gamma-ray spectrometry and mass spectrometry.
Results of the extensive radioactivity screening campaign to identify materials for the construction of XENON100 are reported. This dark matter search experiment is operated underground at Laboratori Nazionali del Gran Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors (HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been applied for a few low mass plastic samples. Detailed tables with the radioactive contaminations of all screened samples are presented, together with the implications for XENON100.
The ϕ-Λ(1520) interference effect in the γp→K^{+}K^{-}p reaction has been measured for the first time in the energy range from 1.673 to 2.173 GeV. The relative phases between ϕ and Λ(1520) production ...amplitudes were obtained in the kinematic region where the two resonances overlap. The measurement results support strong constructive interference when K^{+}K^{-} pairs are observed at forward angles but destructive interference for proton emission at forward angles. Furthermore, the observed interference effect does not account for the sqrts=2.1 GeV bump structure in forward differential cross sections for ϕ photoproduction. This fact suggests possible exotic structures such as a hidden-strangeness pentaquark state, a new Pomeron exchange, or rescattering processes via other hyperon states.