We report on the first long-term application of squeezed vacuum states of light to improve the shot-noise-limited sensitivity of a gravitational-wave observatory. In particular, squeezed vacuum was ...applied to the German-British detector GEO 600 during a period of three months from June to August 2011, when GEO 600 was performing an observational run together with the French-Italian Virgo detector. In a second period, the squeezing application continued for about 11 months from November 2011 to October 2012. During this time, squeezed vacuum was applied for 90.2% (205.2 days total) of the time that science-quality data were acquired with GEO 600. A sensitivity increase from squeezed vacuum application was observed broadband above 400 Hz. The time average of gain in sensitivity was 26% (2.0 dB), determined in the frequency band from 3.7 to 4.0 kHz. This corresponds to a factor of 2 increase in the observed volume of the Universe for sources in the kHz region (e.g., supernovae, magnetars). We introduce three new techniques to enable the long-term application of squeezed light, and show that the glitch rate of the detector did not increase from squeezing application. Squeezed vacuum states of light have arrived as a permanent application, capable of increasing the astrophysical reach of gravitational-wave detectors.
In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the ...test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20 μHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.05) fm s^{-2}/sqrtHz above 2 mHz and (6±1)×10 fm s^{-2}/sqrtHz at 20 μHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency.
The science operations of the LISA Pathfinder mission have demonstrated the feasibility of sub-femto-g free fall of macroscopic test masses necessary to build a gravitational wave observatory in ...space such as LISA. While the main focus of interest, i.e., the optical axis or the x-axis, has been extensively studied, it is also of great importance to evaluate the stability of the spacecraft with respect to all the other degrees of freedom (d.o.f.). The current paper is dedicated to such a study: the exhaustive and quantitative evaluation of the imperfections and dynamical effects that impact the stability with respect to its local geodesic. A model of the complete closed-loop system provides a comprehensive understanding of each component of the in-loop coordinates spectral density. As will be presented, this model gives very good agreement with LISA Pathfinder flight data. It allows one to identify the noise source at the origin and the physical phenomena underlying the couplings. From this, the stability performance of the spacecraft with respect to its geodesic is extracted as a function of frequency. Close to 1 mHz, the stability of the spacecraft on the XSC, YSC and ZSC d.o.f. is shown to be of the order of 5.0×10−15 m s−2 Hz−1/2 for X, 6.0×10−14 m s−2 Hz−1/2 for Y, and 4.0×10−14 m s−2 Hz−1/2 for Z. For the angular d.o.f., the values are of the order of 3×10−12 rad s−2 Hz−1/2 for ΘSC, 5×10−13 rad s−2 Hz−1/2 for HSC, and 3×10−13 rad s−2 Hz−1/2 for ΦSC. Below 1 mHz, however, the stability performances are worsened significantly by the effect of the star tracker noise on the closed-loop system. It is worth noting that LISA is expected to be spared from such concerns, as differential wave-front sensing, an attitude sensor system of much higher precision, will be utilized for attitude control.
A tension-free coaptation is a key factor for the successful outcome of any nerve repair. A variety of host factors influence the outcome of digital nerve repair more than the type of repair per se. ...Although autologous graft remains the reference standard for reconstruction of any critical digital nerve defect, allografts and conduits have assumed an increasing role.
Abstract
LISA Pathfinder (LPF) was a technology pioneering mission designed to test key technologies required for gravitational wave detection in space. In the low frequency regime (milliHertz and ...below), where space-based gravitational wave observatories will operate, temperature fluctuations play a crucial role since they can couple into the interferometric measurement and the test masses’ free-fall accuracy in many ways. A dedicated temperature measurement subsystem, with noise levels in 10 $\mu$K Hz−1/2 down to 1 mHz was part of the diagnostics unit onboard LPF. In this paper we report on the temperature measurements throughout mission operations, characterize the thermal environment, estimate transfer functions between different locations, and report temperature stability (and its time evolution) at frequencies as low as 10 $\mu$Hz, where typically values around 1 K Hz−1/2 were measured.
We present an in depth analysis of the transient events, or glitches, detected at a rate of about one per day in the differential acceleration data of LISA Pathfinder. We show that these glitches ...fall in two rather distinct categories: fast transients in the interferometric motion readout on one side, and true force transient events on the other. The former are fast and rare in ordinary conditions. The second may last from seconds to hours and constitute the majority of the glitches. We present an analysis of the physical and statistical properties of both categories, including a cross-analysis with other time series like magnetic fields, temperature, and other dynamical variables. Based on these analyses we discuss the possible sources of the force glitches and identify the most likely, among which the outgassing environment surrounding the test-masses stands out. We discuss the impact of these findings on the LISA design and operation, and some risk mitigation measures, including experimental studies that may be conducted on the ground, aimed at clarifying some of the questions left open by our analysis.
It has become clear that the stability of the scapholunate joint does not depend wholly on the scapholunate interosseous ligament, but rather on both primary and secondary stabilizers, which form a ...scapholunate ligament complex. Each case of scapholunate instability is unique and should be treated with tissue-specific repairs, which may partly explain why one procedure cannot successfully restore joint stability in every case. Wrist arthroscopy has a pivotal role in both the assessment and treatment of the scapholunate ligament complex derangements. Tears of the foveal attachment of the triangular fibrocartilaginous complex can be an underdiagnosed cause of distal radioulnar joint instability, because the foveal fibers cannot be visualized using the standard radiocarpal arthroscopy portals. Distal radioulnar joint arthroscopy allows for direct visualization and assessment of these fibers, which in turn has spawned a number of open and arthroscopic repair methods. Wrist arthroscopy has gained wider acceptance as a method to fine-tune articular reduction during open and percutaneous fixation of distal radius fractures, and simplifies intra-articular osteotomies for malunion. It can facilitate percutaneous bone grafting of scaphoid nonunions and has a role in the diagnosis and treatment of associated soft tissue lesions. These and other recent developments will be discussed in the following article.
Treatment of distal radius fractures Lichtman, David M; Bindra, Randipsingh R; Boyer, Martin I ...
Journal of the American Academy of Orthopaedic Surgeons,
03/2010, Volume:
18, Issue:
3
Journal Article
Peer reviewed
The clinical practice guideline is based on a systematic review of published studies on the treatment of distal radius fractures in adults. None of the 29 recommendations made by the work group was ...graded as strong; most are graded as inconclusive or consensus; seven are graded as weak. The remaining five moderate-strength recommendations include surgical fixation, rather than cast fixation, for fractures with postreduction radial shortening >3 mm, dorsal tilt >10 degrees , or intra-articular displacement or step-off >2 mm; use of rigid immobilization rather than removable splints for nonsurgical treatment; making a postreduction true lateral radiograph of the carpus to assess dorsal radial ulnar joint alignment; beginning early wrist motion following stable fixation; and recommending adjuvant treatment with vitamin C to prevent disproportionate pain.
The tilt-to-length coupling during the LISA Pathfinder mission has been numerically and analytically modeled for particular time spans. In this work, we investigate the long-term stability of the ...coupling coefficients of this noise. We show that they drifted slowly (by 1 μm / rad and 6 × 10 − 6 in 100 days) and were strongly correlated to temperature changes within the satellite ( 8 μm / rad / K and 30 × 10 − 6 / K ). Based on analytical tilt-to-length coupling models, we attribute the temperature-driven coupling changes to rotations of the test masses and small distortions in the optical setup. Particularly, our findings lead to the conclusion that LISA Pathfinder’s optical baseplate was bent during the cooldown experiment, which started in late 2016 and lasted several months. Published by the American Physical Society 2024
The LISA Pathfinder (LPF) mission successfully demonstrated the feasibility of the technology needed for the future space borne gravitational wave observatory LISA. A key subsystem under study was ...the laser interferometer, which measured the changes in relative distance in between two test masses (TMs). It achieved a sensitivity of 32.0-1.7+2.4 fm/Hz , which was significantly better than the prelaunch tests. This improved performance allowed direct observation of the influence of laser frequency noise in the readout. The differences in optical path lengths between the measurement and reference beams in the individual interferometers of our setup determined the level of this undesired readout noise. Here, we discuss the dedicated experiments performed on LPF to measure these differences with high precision. We reached differences in path length difference between ( 368±5 ) μm and ( 329.6±0.9 ) μm which are significantly below the required level of 1 mm or 1000 μm . These results are an important contribution to our understanding of the overall sensor performance. Moreover, we observed varying levels of laser frequency noise over the course of the mission. We provide evidence that these do not originate from the laser frequency stabilization scheme which worked as expected. Therefore, this frequency stabilization would be applicable to other missions with similar laser frequency stability requirements.