Event reconstruction in the PHENIX central arm spectrometers Mitchell, J.T; Akiba, Y; Aphecetche, L ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2002, Volume:
482, Issue:
1-2
Journal Article
Peer reviewed
Open access
The central arm spectrometers for the PHENIX experiment at the Relativistic Heavy Ion Collider have been designed for the optimization of particle identification in relativistic heavy ion collisions. ...The spectrometers present a challenging environment for event reconstruction due to a very high track multiplicity in a complicated, focusing, magnetic field. In order to meet this challenge, nine distinct detector types are integrated for charged particle tracking, momentum reconstruction, and particle identification. The techniques which have been developed for the task of event reconstruction are described.
Construction and performance of the PHENIX pad chambers Adcox, K.; Ajitanand, J.; Alexander, J. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2003, Volume:
497, Issue:
2
Journal Article
Peer reviewed
We present the Pad Chamber detector system in the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The three station system provides space points ...along each track in the spectrometer arms at mid-rapidity and covers a total area of
88
m
2
. Its main functions are to provide the track coordinate along the beam and to ensure reliable pattern recognition at very high particle multiplicity. A new concept for two dimensional wire chamber readout via its finely segmented cathode was developed. The full readout system, comprising
172
800
electronic channels, is described together with the challenging design of the chambers. The electronics, mounted on the outer chamber face, together with the chamber itself amounts to 1.2% of a radiation length. Results from cosmic ray tests, showing an average efficiency better than 99.5% for all chambers are presented. The experiences from the full scale operation in the first run are reported.
The ALICE Silicon Pixel Detector Kluge, A.; Rinella, G. Aglieri; Anelli, G. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2007, Volume:
582, Issue:
3
Journal Article
Peer reviewed
Open access
The ALICE Silicon Pixel Detector (SPD) forms the two innermost layers of the ALICE inner tracker system. It contains 9.8×10
6 pixels with a material budget of less than 1% of
X