We present an improved search for neutrinoless double-beta (0νββ) decay of ^{136}Xe in the KamLAND-Zen experiment. Owing to purification of the xenon-loaded liquid scintillator, we achieved a ...significant reduction of the ^{110m}Ag contaminant identified in previous searches. Combining the results from the first and second phase, we obtain a lower limit for the 0νββ decay half-life of T_{1/2}^{0ν}>1.07×10^{26} yr at 90% C.L., an almost sixfold improvement over previous limits. Using commonly adopted nuclear matrix element calculations, the corresponding upper limits on the effective Majorana neutrino mass are in the range 61-165 meV. For the most optimistic nuclear matrix elements, this limit reaches the bottom of the quasidegenerate neutrino mass region.
Hepatocellular carcinoma (HCC) ranks as the third leading cause of cancer deaths worldwide. While sorafenib, a multikinase inhibitor targeting the Raf/extracellular signal-regulated protein kinase ...(ERK) pathway, has been shown recently to provide a survival advantage to patients with advanced HCC, a predictive biomarker has not been developed. We studied whether c-Jun N-terminal kinase (JNK), which promotes liver carcinogenesis in mice, affects therapeutic response to sorafenib in HCC patients.
We collected pathological specimens from 39 patients with advanced HCC before starting sorafenib treatment, and measured JNK activity in HCCs.
In patients treated with sorafenib, the expression of phospho-c-Jun in HCC, as a read out of JNK activity, was significantly higher (P<0.001) in the non-responder group than in the responder group. c-Jun N-terminal kinase activation in HCC was associated with a decreased time to progression and a poor overall survival (P=0.0028 and P=0.0008, respectively).
In addition, JNK activity was significantly correlated with CD133 expression level. Correspondingly, high expression level of CD133 was linked to a poor response to sorafenib. Furthermore, D-JNKi, a specific JNK inhibitor, reduced the growth of xenografted CD133(+) cells in athymic mice. In conclusion, JNK activation was positively correlated with CD133 expression level and inversely correlated with the therapeutic response to sorafenib, suggesting that JNK activity may be considered as a new predictive biomarker for response to sorafenib treatment.
Inner balloon production for KamLAND-Zen 800 Gando, A; Gando, Y; Hachiya, T ...
Journal of physics. Conference series,
02/2020, Volume:
1468, Issue:
1
Journal Article, Conference Proceeding
Peer reviewed
Open access
Abstract
KamLAND-Zen searches for neutrinoless double-beta decay with
136
Xe loaded liquid scintillator (LS). The LS container, a 25-
μ
m-thick clean nylon inner balloon is a key of the experiment ...since one of the main backgrounds in the ROI is
214
Bi from the inner balloon. In KamLAND-Zen 400 (operated from 2011 to 2015), dust contamination of the inner balloon from the environment limited the sensitivity, although the inner balloon was fabricated at a class-1 super clean room. We improved the production method of the inner balloon for KamLAND-Zen 800 (started DAQ in January, 2019) and successfully reduced the
214
Bi background level to one fifteenth as compared to the 2nd phase of KamLAND-Zen 400. The inner balloon film material and requirements, improved fabrication scheme, including establishment of clean environment and dust control, will be described.
Magnesium (Mg) plays an essential role in a wide range of fundamental cellular reactions in patients with ischemic heart disease. It has been well known that Mg plays a pivotal role in control of ...cardiac excitability, neuromuscular transmission, vasomotor tone, and blood pressure, among other functions. Especially, many epidemiological, experimental, and clinical studies support a pathological role for Mg in the etiology and development of major coronary risk factors as diabetes mellitus, hypertension, and hyperlipidemia as well as ischemic heart disease. Furthermore, the therapeutic value of Mg in the management of coronary risk factors and ischemic heart disease has been clarified. Dietary Mg supplementation should be considered as a preventive element in atherosclerosis and ischemic heart disease.
A search for light dark matter using low-threshold data from the single phase liquid xenon scintillation detector XMASS, has been conducted. Using the entire 835 kg inner volume as target, the ...analysis threshold can be lowered to 0.3 keVee (electron-equivalent) to search for light dark matter. With low-threshold data corresponding to a 5591.4 kg day exposure of the detector and without discriminating between nuclear-recoil and electronic events, XMASS excludes part of the parameter space favored by other experiments.
Radon removal from gaseous xenon with activated charcoal Abe, K.; Hieda, K.; Hiraide, K. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2012, 2012-01-00, 20120101, Volume:
661, Issue:
1
Journal Article
Peer reviewed
Many low background experiments using xenon need to remove radioactive radon to improve their sensitivities. However, no method of continually removing radon from xenon has been described in the ...literature. We studied a method to remove radon from xenon gas through an activated charcoal trap. From our measurements we infer a linear relationship between the mean propagation velocity
v
Rn
of radon and
v
Xe
of xenon in the trap with
v
Rn
/
v
Xe
=
(
0.96
±
0.10
)
×
10
−
3
at −85
°C. As the mechanism for radon removal in this charcoal trap is its decay, knowledge of this parameter allows us to design an efficient radon removal system for the XMASS experiment. The verification of this system found that it reduces radon by a factor of 0.07, which is in line with its expected average retention time of 14.8 days for radon.
Abstract
A high-pressure xenon gas time projection chamber, with a unique cellular readout structure based on electroluminescence, has been developed for a large-scale neutrinoless double-beta decay ...search. In order to evaluate the detector performance and validate its design, a 180 L size prototype is being constructed and its commissioning with partial detector has been performed. The obtained energy resolution at 4.0 bar is 1.73 $\pm$ 0.07% (FWHM) at 511 keV. The energy resolution at the $^{136}$Xe neutrinoless double-beta decay $Q$-value is estimated to be between 0.79 and 1.52% (FWHM) by extrapolation. Reconstructed event topologies show patterns peculiar to the track endpoint that can be used to distinguish $0\nu\beta\beta$ signals from gamma-ray backgrounds.