Objectives A novel Y-shaped baffle has been proposed for the Fontan operation with promising initial results. However, previous studies have relied either on idealized models or a single ...patient-specific model. The objective of this study is to comprehensively compare the hemodynamic performance and hepatic blood flow distribution of the Y-graft Fontan baffle with 2 current designs using multiple patient-specific models. Methods Y-shaped and tube-shaped grafts were virtually implanted into 5 patient-specific Glenn models forming 3 types of Fontan geometries: Y-graft, T-junction, and offset. Unsteady flow simulations were performed at rest and at varying exercise conditions. The hepatic flow distribution between the right and left lungs was carefully quantified using a particle tracking method. Other physiologically relevant parameters such as energy dissipation, superior vena cava pressure, and wall shear stress were evaluated. Results The Fontan geometry significantly influences the hepatic flow distribution. The Y-graft design improves the hepatic flow distribution effectively in 4 of 5 patients, whereas the T-junction and offset designs may skew as much as 97% of hepatic flow to 1 lung in 2 cases. Sensitivity studies show that changes in pulmonary flow split can affect the hepatic flow distribution dramatically but that some Y-graft and T-junction designs are relatively less sensitive than offset designs. The Y-graft design offers moderate improvements over the traditional designs in power loss and superior vena cava pressure in all patients. Conclusions The Y-graft Fontan design achieves overall superior hemodynamic performance compared with traditional designs. However, the results emphasize that no one-size-fits-all solution is available that will universally benefit all patients and that designs should be customized for individual patients before clinical application.
Abstract Background Computational fluid dynamics has been increasingly used in congenital heart surgery to simulate pathophysiological blood flow, investigate surgical options, or design medical ...devices. Several commercial and research computational or numerical codes have been developed. They present different approaches to numerically solve the blood flow equations, raising the question whether these numerical codes are equally reliable to achieve accurate simulation results. Accordingly, we sought to examine the influence of numerical code selection in several complex congenital cardiac operations. Material and methods The main steps of blood flow simulations are detailed (geometrical mesh, boundary conditions, and solver numerical methods) for congenital cardiac operations of increasing complexity. The first case tests different numerical solutions against an analytical, or exact, solution. In the second case, the three-dimensional domain is a patient-specific superior cavopulmonary anastomosis. As an analytical solution does not exist in such a complex geometry, different numerical solutions are compared. Finally, a realistic case of a systemic-to-pulmonary shunt is presented with both geometrically and physiologically challenging conditions. For all, solutions from a commercially available code and an open-source research code are compared. Results In the first case, as the mesh or solver numerical method is refined, the simulation results for both codes converged to the analytical solution. In the second example, velocity differences between the two codes are greater when the resolution of the mesh were lower and less refined. The third case with realistic anatomy reveals that the pulsatile complex flow is very similar for both codes. Conclusions The precise setup of the numerical cases has more influence on the results than the choice of numerical codes. The need for detailed construction of the numerical model that requires high computational cost depends on the precision needed to answer the biomedical question at hand and should be assessed for each problem on a combination of clinically relevant patient-specific geometry and physiological conditions.