Abstract Objective The objective of this project, which was initiated from the Academy of Dental Materials, was to review and critically appraise methods to determine fracture, deformation and wear ...resistance of dental resin composites, in an attempt to provide guidance for investigators endeavoring to study these properties for these materials. Methods Test methods have been ranked in the priority of the specific property being tested, as well as of the specific test methods for evaluating that property. Focus was placed on the tests that are considered to be of the highest priority in terms of being the most useful, applicable, supported by the literature, and which show a correlation with clinical findings. Others are mentioned briefly for the purpose of being inclusive. When a standard test method exists, including those used in other fields, these have been identified in the beginning of each section. Also, some examples from the resin composite literature are included for each test method. Results The properties for evaluating resin composites were ranked in the priority of measurement as following: (1) Strength, Elastic Modulus, Fracture toughness, Fatigue, Indentation Hardness, Wear—abrasion (third body) and Wear—attrition (contact/two body), (2) Toughness, Edge strength (chipping) and (3) Wear determined by toothbrush. Significance The following guidance is meant to aid the researcher in choosing the proper method to assess key properties of dental resin composites with regard to their fracture, deformation and wear resistance.
Abstract Objectives To determine the post-cure depth of cure of bulk fill resin composites through using Vickers hardness profiles (VHN). Methods Five bulk fill composite materials were examined: ...Tetric EvoCeram® Bulk Fill, X-tra base, Venus® Bulk Fill, Filtek™ Bulk Fill, SonicFill™. Three specimens of each material type were prepared in stainless steel molds which contained a slot of dimensions (15 mm × 4 mm × 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37 °C for 24 h, before measurement. The Vickers hardness was measured as a function of depth of material, at 0.3 mm intervals. Data were analysed by one-way ANOVA using Tukey post hoc tests ( α = 0.05). Results The maximum VHN ranged from 37.8 to 77.4, whilst the VHN at 80% of max.VHN ranged from 30.4 to 61.9. The depth corresponding to 80% of max.VHN, ranged from 4.14 to 5.03 mm. One-way ANOVA showed statistically significant differences between materials for all parameters tested. SonicFill exhibited the highest VHN ( p < 0.001) while Venus Bulk Fill the lowest ( p ≤ 0.001). SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure (5.03 and 4.47 mm, respectively) and was significant's different from X-tra base, Venus Bulk Fill and Filtek Bulk Fill ( p ≤ 0.016). Linear regression confirmed a positive regression between max.VHN and filler loading ( r2 = 0.94). Significance Bulk fill resin composites can be cured to an acceptable post-cure depth, according to the manufacturers’ claims. SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure among the composites examined.
The objective of this work, commissioned by the Academy of Dental Materials, was to review and critically appraise test methods to characterize properties related to critical issues for dental resin ...composites, including technique sensitivity and handling, polymerization, and dimensional stability, in order to provide specific guidance to investigators planning studies of these properties.
The properties that relate to each of the main clinical issues identified were ranked in terms of their priority for testing, and the specific test methods within each property were ranked. An attempt was made to focus on the tests and methods likely to be the most useful, applicable, and supported by the literature, and where possible, those showing a correlation with clinical outcomes. Certain methods are only briefly mentioned to be all-inclusive. When a standard test method exists, whether from dentistry or another field, this test has been identified. Specific examples from the literature are included for each test method.
The properties for evaluating resin composites were ranked in the priority of measurement as follows: (1) porosity, radiopacity, sensitivity to ambient light, degree of conversion, polymerization kinetics, depth of cure, polymerization shrinkage and rate, polymerization stress, and hygroscopic expansion; (2) stickiness, slump resistance, and viscosity; and (3) thermal expansion.
The following guidance is meant to aid the researcher in choosing the most appropriate test methods when planning studies designed to assess certain key properties and characteristics of dental resin composites, specifically technique sensitivity and handling during placement, polymerization, and dimensional stability.
This article reviews recent research into alternative systems of food provision. It considers, first, what the concept of`alternativeness' might mean, based on recent discussions in economic ...geography. Informed by this, it discusses food relocalization and the turn to `quality' food production, arguing that both are `weaker' alternative systems of food provision because of their emphasis on food. It then examines some `stronger' alternative systems of food provision, which emphasize the networks through which food passes. Lastly, the paper reflects on the concept of alternativeness in the context of food supply chains, and suggests some possible directions for future research.
Point mutations in the amyloid-β (Aβ) coding region produce a combination of mutant and WT Aβ isoforms that yield unique clinicopathologies in familial Alzheimer’s disease (fAD) and cerebral amyloid ...angiopathy (fCAA) patients. Here, we report a method to investigate the structural variability of amyloid deposits found in fAD, fCAA, and sporadic AD (sAD). Using this approach, we demonstrate that mutant Aβ determines WT Aβ conformation through prion template-directed misfolding. Using principal component analysis of multiple structure-sensitive fluorescent amyloid-binding dyes, we assessed the conformational variability of Aβ deposits in fAD, fCAA, and sAD patients. Comparing many deposits from a given patient with the overall population, we found that intrapatient variability is much lower than interpatient variability for both disease types. In a given brain, we observed one or two structurally distinct forms. When two forms coexist, they segregate between the parenchyma and cerebrovasculature, particularly in fAD patients. Compared with sAD samples, deposits from fAD patients show less intersubject variability, and little overlap exists between fAD and sAD deposits. Finally, we examined whether E22G (Arctic) or E22Q (Dutch) mutants direct the misfolding of WT Aβ, leading to fAD-like plaques in vivo. Intracerebrally injecting mutant Aβ40 fibrils into transgenic mice expressing only WT Aβ induced the deposition of plaques with many biochemical hallmarks of fAD. Thus, mutant Aβ40 prions induce a conformation of WT Aβ similar to that found in fAD deposits. These findings indicate that diverse AD phenotypes likely arise from one or more initial Aβ prion conformations, which kinetically dominate the spread of prions in the brain.
To study the effect of water storage (3 months) on the creep deformation and recovery of CAD/CAM composite materials to determine their viscoelastic stability.
Five CAD/CAM composite blocks, with ...increasing filler loading, and one polymer-infiltrated ceramic network (PICN) were studied. Six specimens of each material were separated into two groups (n=3) according to their storage conditions (24 h dry storage at 23°C versus 3 months storage in 37°C distilled water). A constant static compressive stress of 20 MPa was applied on each specimen via a loading pin for 2 h followed by unloading and monitoring strain recovery for a further period of 2 h. The maximum creep-strain (%) and permanent set (%) were recorded. Data were analysed via two-way ANOVA followed by one-way ANOVA and Bonferroni post hoc tests (<0.05) for comparisons between the materials. Homogeneity of variance was calculated via Levene’s statistics.
The maximum creep strain after 24 h dry ranged from 0.45% to 1.09% and increased after 3-month storage in distilled water to between 0.71% and 1.85%. The permanent set after 24 h dry storage ranged from 0.033% to 0.15% and increased after 3-month water storage to between 0.087% and 0.18%. The maximum creep strain also reduced with increasing filler loading.
The PICN material exhibited superior dimensional stability to all of the pre-cured resin composite blocks in both storage conditions with deformation being predominantly elastic rather than viscoelastic. Notwithstanding, two of the resin-matrix composite blocks approached the PICN performance, when dry, but less so after water storage.
Dietary mineral supplies in Africa Joy, Edward J. M; Ander, E. Louise; Young, Scott D ...
Physiologia plantarum,
July 2014, Volume:
151, Issue:
3
Journal Article
Peer reviewed
Open access
Dietary micronutrient deficiencies (MNDs) are widespread, yet their prevalence can be difficult to assess. Here, we estimate MND risks due to inadequate intakes for seven minerals in Africa using ...food supply and composition data, and consider the potential of food‐based and agricultural interventions. Food Balance Sheets (FBSs) for 46 countries were integrated with food composition data to estimate per capita supply of calcium (Ca), copper (Cu), iron (Fe), iodine (I), magnesium (Mg), selenium (Se) and zinc (Zn), and also phytate. Deficiency risks were quantified using an estimated average requirement (EAR) ‘cut‐point’ approach. Deficiency risks are highest for Ca (54% of the population), followed by Zn (40%), Se (28%) and I (19%, after accounting for iodized salt consumption). The risk of Cu (1%) and Mg (<1%) deficiency are low. Deficiency risks are generally lower in the north and west of Africa. Multiple MND risks are high in many countries. The population‐weighted mean phytate supply is 2770 mg capita⁻¹ day⁻¹. Deficiency risks for Fe are lower than expected (5%). However, ‘cut‐point’ approaches for Fe are sensitive to assumptions regarding requirements; e.g. estimates of Fe deficiency risks are 43% under very low bioavailability scenarios consistent with high‐phytate, low‐animal protein diets. Fertilization and breeding strategies could greatly reduce certain MNDs. For example, meeting HarvestPlus breeding targets for Zn would reduce dietary Zn deficiency risk by 90% based on supply data. Dietary diversification or direct fortification is likely to be needed to address Ca deficiency risks.
The aim was to investigate shear bond strengths and failure modes of four self-etch bonding agents to bovine dentin and enamel and to compare evaluation of data sets with or without exclusion of ...cohesive failure specimens.
Composite-cylinders were bonded perpendicularly to bovine dentin and enamel surfaces. Shear-strengths were measured 24 h post-bonding of: Scotchbond Universal® (SBU, 3 M), OptiBond™ XTR (OBXTR, Kerr), OptiBond™ universal (OBU, KaVo-Kerr) and Prime & Bond active® (PBA, Dentsply-Sirona). Analysis of overall data was made via a linear mixed-model. This was repeated after exclusion of specimens associated with cohesive failures.
When both adhesive and cohesive failures were considered, OBU and OBXTR showed comparable dentin and enamel bond strengths, whereas lower strengths were found on enamel for SBU (p < 0.001) and PBA (p = 0.015). For OBXTR higher shear strengths were measured for specimens associated with cohesive failures. When cohesive failures were excluded, the majority of shear bond strengths of adhesive failure specimens were only slightly different from overall results. However, uniquely with OBXTR dramatically lower shear bond strengths were found for dentin substrate.
After exclusion of cases with cohesive failures OBXTR adhesive fell behind other materials in the sequence of average shear strengths. This did not reflect the actual performance of the material. Therefore, in statistical analysis we do not recommend exclusion of data based on a specific fracture mode.