The spatial resolution along the pad-row direction was measured with a GEM-based TPC prototype for the future linear collider experiment in order to understand its performance for tracks with finite ...projected angles with respect to the pad-row normal. The degradation of the resolution due to the angular pad effect was confirmed to be consistent with the prediction of a simple calculation taking into account the cluster-size distribution and the avalanche fluctuation.
A time projection chamber (TPC) is a strong candidate for the central tracker of the international linear collider (ILC) experiment and we have been conducting a series of cosmic ray experiments ...under a magnetic field up to 4T, using a small prototype TPC with a replaceable readout device: multi-wire proportional chamber (MWPC) or gas electron multiplier (GEM). We first confirmed that the MWPC readout could not be a fall-back option of the ILC-TPC under a strong axial magnetic field of 4T since its spatial resolution suffered severely from the so called E×B effect in the vicinity of the wire planes. The GEM readout, on the other hand, was found to be virtually free from the E×B effect and gave the resolution determined by the transverse diffusion of the drift electrons (diffusion limited). Furthermore, GEMs allow a wider choice of gas mixtures than MWPCs. Among the gases we tried so far a mixture of Ar–CF4-isobutane seems promising as the operating gas of the ILC-TPC because of its small diffusion constant especially under a strong magnetic field. We report the spatial resolution obtained with the GEM readout in this gas mixture. Also presented is the spatial resolution of a GEM-based ILC-TPC estimated from the measurement with the prototype.
In Japan, acute pulmonary thromboembolism (APTE) is still rare, but the number of patients with APTE has been steadily increasing. It is important for early diagnosis and early management of APTE to ...recognize epidemiological characteristics of this condition.
We investigated the epidemiological characteristics of 252 patients with APTE who were admitted to our institutions between 1975 and 2001. APTE was more prevalent in women that in men. It was observed the most in the age group between 50s to 70s, especially in women. Many patients had prolonged immobilization, recent major operation, obesity, or cancer, as risk factors for venous thromboembolism. One hundred and thirty-eight patients developed APTE in hospital; 60 patients were in Department of Internal Medicine, 28 in General Surgery, 15 in Orthopedics, 15 in Obstetrics and Gynecology, and 20 in other services.
Among 58 patients with malignancy, 43% had cancers in digestive organs, 21% in gynecological, and 17% in urological. Among 61 patients who were examined for the presence of thrombophilia, 13 patients had inherited thrombophilia (8 protein C deficiency, 4 protein S deficiency, and 1 antithrombin III deficiency) 11 had antiphospholipid antibodies which indicated thrombophilia. Five out of the above 61 patients (8%) had no obvious risk factors including thrombophilia.
The findings in our patients were almost the same as those in Western patients, except for some points. These results might be useful to establish a preventive approach for APTE in Japan.
The spatial resolution along the pad-row direction was measured with a GEM-based TPC prototype for the future linear collider experiment in order to understand its performance for tracks with finite ...projected angles with respect to the pad-row normal. The degradation of the resolution due to the angular pad effect was confirmed to be consistent with the prediction of a simple calculation taking into account the cluster-size distribution and the avalanche fluctuation.