ABSTRACT We present preliminary results of the quasar survey in the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) first data release (DR1), which includes the pilot survey and ...the first year of the regular survey. There are 3921 quasars reliably identified, among which 1180 are new quasars discovered in the survey. These quasars are at low to median redshifts, with a highest z of 4.83. We compile emission line measurements around the H , Hβ, Mg ii, and C iv regions for the new quasars. The continuum luminosities are inferred from SDSS photometric data with model fitting, as the spectra in DR1 are non-flux-calibrated. We also compile the virial black hole mass estimates, with flags indicating the selection methods, and broad absorption line quasars. The catalog and spectra for these quasars are also available. Of the 3921 quasars, 28% are independently selected with optical-infrared colors, indicating that the method is quite promising for the completeness of the quasar survey. LAMOST DR1 and the ongoing quasar survey will provide valuable data for studies of quasars.
Previous results from our trial showed that adding oxaliplatin to radiotherapy (RT) increased survival in patients with locoregionally advanced nasopharyngeal carcinoma (NPC) at 2 years. Here, we ...present the data of long-term efficacy and late toxic effects.
Between January 2001 and January 2003, 115 Patients with nonkeratinizing/undifferentiated locoregionally advanced NPC were randomly to receive either RT alone (n = 56) or plus concurrent oxaliplatin 70 mg/m2 weekly for six cycles (n = 59).
After a median follow-up of 114 months (range 18–139 months), the 5-year overall survival (OS) and metastasis-free survival (MFS) rates in the concurrent chemoradiotherapy (CCRT) group were significantly higher than those observed in the RT-alone group (OS, 73.2% versus 60.2%, P = 0.028; MFS, 74.7% versus 63.0%, P = 0.027). However, CCRT did not improve locoregional failure-free survival significantly. Subgroup analyses showed that the superiorities of CCRT mainly existed in the T3-4N0-1 stage subgroup (OS: HR = 0.394, P = 0.034). The grade 3/4 late toxic effects were similar in the two groups.
The long-term follow-up data confirms the role of CCRT as a treatment of locoregionally advanced NPC. Oxaliplatin can be considered as an alternative optional therapeutic regimen for these patients due to its high efficiency and low toxic effect.
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses (mχ) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on ...time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg day exposure and 250 eVee threshold for AM analysis. The sensitive windows in mχ are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on σχNSI at 90% confidence level are derived as 2×10−32∼7×10−35 cm2 for TI analysis at mχ∼50–180 MeV/c2, and 3×10−32∼9×10−38 cm2 for AM analysis at mχ∼75 MeV/c2–3.0 GeV/c2.
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass p-type point-contact germanium detector of the CDEX-1B ...experiment at the China Jinping Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2-yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus (χ-N) spin-independent cross sections as function of WIMP mass (m_{χ}) at 90% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at >99.99% and 98% C.L., respectively. These results correspond to the best sensitivity at m_{χ}<6 GeV/c^{2} among WIMP AM measurements to date.
The process e+e- → Λ Λ ¯ is studied using data samples at √s = 2.2324, 2.400, 2.800 and 3.080 GeV collected with the BESIII detector operating at the BEPCII collider. The Born cross section is ...measured at √s=2.2324 GeV, which is 1.0 MeV above the Λ Λ ¯ mass threshold, to be 305±$45_{-36}^{+66}$ pb, where the first uncertainty is statistical and the second systematic. The substantial cross section near threshold is significantly larger than that expected from theory, which predicts the cross section to vanish at threshold. The Born cross sections at √s=2.400, 2.800 and 3.080 GeV are measured and found to be consistent with previous experimental results, but with improved precision. Finally, the corresponding effective electromagnetic form factors of Λ are deduced.
We report temporal patterns of viral shedding in 94 patients with laboratory-confirmed COVID-19 and modeled COVID-19 infectiousness profiles from a separate sample of 77 infector-infectee ...transmission pairs. We observed the highest viral load in throat swabs at the time of symptom onset, and inferred that infectiousness peaked on or before symptom onset. We estimated that 44% (95% confidence interval, 25-69%) of secondary cases were infected during the index cases' presymptomatic stage, in settings with substantial household clustering, active case finding and quarantine outside the home. Disease control measures should be adjusted to account for probable substantial presymptomatic transmission.
We aimed to conduct a meta-analysis to evaluate the efficacy of repetitive transcranial magnetic stimulation (rTMS) in patients with post-stroke depression (PSD). Six relevant electronic databases ...(PubMed, CENTRAL, Embase, Web of Science, CINAHL, and PsycINFO) were searched. Randomized controlled trials (RCTs) that compared rTMS with control condition for PSD were included. The mean change in depression symptom scores was defined as the primary efficacy outcome. Secondary outcomes included the remission rate of depression, stroke recovery, and cognitive function recovery. In total, 7 RCTs with 351 participants were included. At post-treatment, rTMS was significantly more effective than the control condition, with a standardized mean difference (SMD) of -1.15 (95%CI: -1.62 to -0.69; P<0.001, I2=71%) and remission with an odds ratio (OR) of 3.46 (95%CI: 1.68 to 7.12; P<0.001; I2=11%). As for stroke recovery, rTMS was also better than the control condition (SMD=-0.67, 95%CI: -1.02 to -0.32; P<0.001). However, no significant difference was found for cognitive function recovery between the two groups (SMD=4.07, 95%CI: -1.41 to 9.55; P=0.15). To explore the potential moderators for the primary outcome, a series of subgroup and sensitivity analyses were performed. The results implied that rTMS may be more effective in Asian samples than in North American samples (P=0.03). In conclusion, from the current evidence in this study, rTMS could be an effective treatment for patients with PSD. Further clinical studies with larger sample sizes and clearer subgroup definitions are needed to confirm these outcomes.
ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).
Recently a dark matter-electron (DM-electron) paradigm has drawn much attention. Models beyond the standard halo model describing DM accelerated by high energy celestial bodies are under intense ...examination as well. In this Letter, a velocity components analysis (VCA) method dedicated to swift analysis of accelerated DM-electron interactions via semiconductor detectors is proposed and the first HPGe detector-based accelerated DM-electron analysis is realized. Utilizing the method, the first germanium based constraint on sub-GeV solar reflected DM-electron interaction is presented with the 205.4 kg·day dataset from the CDEX-10 experiment. In the heavy mediator scenario, our result excels in the mass range of 5-15 keV/c^{2}, achieving a 3 orders of magnitude improvement comparing with previous semiconductor experiments. In the light mediator scenario, the strongest laboratory constraint for DM lighter than 0.1 MeV/c^{2} is presented. The result proves the feasibility and demonstrates the vast potential of the VCA technique in future accelerated DM-electron analyses with semiconductor detectors.