Background
Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off‐pump and on‐pump CABG respectively. However, the preferable technique ...is unclear.
Objectives
To assess the benefits and harms of off‐pump versus on‐pump CABG in patients with ischaemic heart disease.
Search methods
We searched the Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library (Issue 1, 2011), MEDLINE (OVID, 1950 to February 2011), EMBASE (OVID, 1980 to February 2011), Science Citation Index Expanded on ISI Web of Science (1970 to February 2011) and CINAHL (EBSCOhost, 1981 to February 2011) on 2 February 2011. No language restrictions were applied.
Selection criteria
Randomised clinical trials of off‐pump versus on‐pump CABG irrespective of language, publication status and blinding were selected for inclusion.
Data collection and analysis
For statistical analysis of dichotomous data risk ratio (RR) and for continuous data mean difference (MD) with 95% confidence intervals (CI) were used. Trial sequential analysis (TSA) was used for analysis to assess the risk of random error due to sparse data and to multiple updating of accumulating data.
Main results
Eighty‐six trials (10,716 participants) were included. Ten trials (4,950 participants) were considered to be low risk of bias. Pooled analysis of all trials showed that off‐pump CABG increased all‐cause mortality compared with on‐pump CABG (189/5,180 (3.7%) versus 160/5144 (3.1%); RR 1.24, 95% CI 1.01 to 1.53; P =.04). In the trials at low risk of bias the effect was corroborated (154/2,485 (6.2%) versus 113/2,465 (4.5%), RR 1.35,95% CI 1.07 to 1.70; P =.01). TSA showed that the risk of random error on the result was unlikely. Off‐pump CABG resulted in fewer distal anastomoses (MD ‐0.28; 95% CI ‐0.40 to ‐0.16, P <.00001). No significant differences in myocardial infarction, stroke, renal insufficiency, or coronary re‐intervention were observed. Off‐pump CABG reduced post‐operative atrial fibrillation compared with on‐pump CABG, however, in trials at low risk of bias, the estimated effect was not significantly different.
Authors' conclusions
Our systematic review did not demonstrate any significant benefit of off‐pump compared with on‐pump CABG regarding mortality, stroke, or myocardial infarction. In contrast, we observed better long‐term survival in the group of patients undergoing on‐pump CABG with the use of cardiopulmonary bypass and cardioplegic arrest. Based on the current evidence, on‐pump CABG should continue to be the standard surgical treatment. However, off‐pump CABG may be acceptable when there are contraindications for cannulation of the aorta and cardiopulmonary bypass. Further randomised clinical trials should address the optimal treatment in such patients.
Coronary-artery bypass grafting (CABG) surgery may be performed either with cardiopulmonary bypass (on pump) or without cardiopulmonary bypass (off pump). We report the 5-year clinical outcomes in ...patients who had been included in the Veterans Affairs trial of on-pump versus off-pump CABG.
From February 2002 through June 2007, we randomly assigned 2203 patients at 18 medical centers to undergo either on-pump or off-pump CABG, with 1-year assessments completed by May 2008. The two primary 5-year outcomes were death from any cause and a composite outcome of major adverse cardiovascular events, defined as death from any cause, repeat revascularization (CABG or percutaneous coronary intervention), or nonfatal myocardial infarction. Secondary 5-year outcomes included death from cardiac causes, repeat revascularization, and nonfatal myocardial infarction. Primary outcomes were assessed at a P value of 0.05 or less, and secondary outcomes at a P value of 0.01 or less.
The rate of death at 5 years was 15.2% in the off-pump group versus 11.9% in the on-pump group (relative risk, 1.28; 95% confidence interval CI, 1.03 to 1.58; P=0.02). The rate of major adverse cardiovascular events at 5 years was 31.0% in the off-pump group versus 27.1% in the on-pump group (relative risk, 1.14; 95% CI, 1.00 to 1.30; P=0.046). For the 5-year secondary outcomes, no significant differences were observed: for nonfatal myocardial infarction, the rate was 12.1% in the off-pump group and 9.6% in the on-pump group (P=0.05); for death from cardiac causes, the rate was 6.3% and 5.3%, respectively (P=0.29); for repeat revascularization, the rate was 13.1% and 11.9%, respectively (P=0.39); and for repeat CABG, the rate was 1.4% and 0.5%, respectively (P=0.02).
In this randomized trial, off-pump CABG led to lower rates of 5-year survival and event-free survival than on-pump CABG. (Funded by the Department of Veterans Affairs Office of Research and Development Cooperative Studies Program and others; ROOBY-FS ClinicalTrials.gov number, NCT01924442 .).
Despite several studies comparing off- and on-pump coronary artery bypass grafting (CABG), the effectiveness and outcomes of off-pump CABG still remain uncertain.
In this registry-based study, we ...assessed 8163 patients who underwent isolated CABG between 2014 and 2016. Propensity score matching (PSM), inverse probability of weighting (IPW) and covariate adjustment were performed to correct for and minimize selection bias.
The overall mean age of the patients was 62 years, and 25.7% were women. Patients who underwent off-pump CABG had shorter length of hospitalization (p < 0.001), intubation time (p = 0.003) and length of ICU admission (p < 0.001). Off-pump CABG was associated with higher risk of 30-days mortality (OR: 1.7; 95% CI 1.09-2.65; p = 0.019) in unadjusted analysis. After covariate adjustment and matching (PSM and IPW), this difference was not statistically significant. After an average of 36.1 months follow-up, risk of MACCE and all-cause mortality didn't have significant differences in both surgical methods by adjusting with IPW (HR: 1.03; 95% CI 0.87-1.24; p = 0.714; HR: 0.91; 95% CI 0.73-1.14; p = 578, respectively).
Off-pump and on-pump techniques have similar 30-day mortality (adjusted, PSM and IPW). Off-pump surgery is probably more cost-effective in short term; however, mid-term survival and MACCE trends in both surgical methods are comparable.
We previously reported that there was no significant difference at 30 days or at 1 year in the rate of the composite outcome of death, stroke, myocardial infarction, or renal failure between patients ...who underwent coronary-artery bypass grafting (CABG) performed with a beating-heart technique (off-pump) and those who underwent CABG performed with cardiopulmonary bypass (on-pump). We now report the results at 5 years (the end of the trial).
A total of 4752 patients (from 19 countries) who had coronary artery disease were randomly assigned to undergo off-pump or on-pump CABG. For this report, we analyzed a composite outcome of death, stroke, myocardial infarction, renal failure, or repeat coronary revascularization (either CABG or percutaneous coronary intervention). The mean follow-up period was 4.8 years.
There were no significant differences between the off-pump group and the on-pump group in the rate of the composite outcome (23.1% and 23.6%, respectively; hazard ratio with off-pump CABG, 0.98; 95% confidence interval CI, 0.87 to 1.10; P=0.72) or in the rates of the components of the outcome, including repeat coronary revascularization, which was performed in 2.8% of the patients in the off-pump group and in 2.3% of the patients in the on-pump group (hazard ratio, 1.21; 95% CI, 0.85 to 1.73; P=0.29). The secondary outcome for the overall period of the trial - the mean cost in U.S. dollars per patient - also did not differ significantly between the off-pump group and the on-pump group ($15,107 and $14,992, respectively; between-group difference, $115; 95% CI, -$697 to $927). There were no significant between-group differences in quality-of-life measures.
In our trial, the rate of the composite outcome of death, stroke, myocardial infarction, renal failure, or repeat revascularization at 5 years of follow-up was similar among patients who underwent off-pump CABG and those who underwent on-pump CABG. (Funded by the Canadian Institutes of Health Research; CORONARY ClinicalTrials.gov number, NCT00463294 .).
Abstract Objectives To assess the benefits and risks of off-pump coronary artery bypass (OPCAB) versus coronary artery bypass grafting (CABG) through a meta-analysis of randomized controlled trials ...(RCTs), and to investigate the relationship between outcomes and patient risk profile. Methods PubMed, Embase, the Cumulative Index of Nursing and Allied Health Literature, Scopus, Web of Science, Cochrane Library, and major conference proceedings databases were searched for RCTs comparing OPCAB and CABG and reporting short-term (≤30 days) outcomes. Endpoints assessed were all-cause mortality, myocardial infarction (MI), and cerebral stroke. Results The meta-analysis included 100 studies, with a total of 19,192 subjects. There was no difference between the 2 techniques with respect to all-cause mortality and MI (odds ratio OR, 0.88; 95% confidence interval CI, 0.71-1.09; P = .25; I2 = 0% and OR, 0.90; 95% CI, 0.77-1.05; P = .19; I2 = 0%, respectively). OPCAB was associated with a significant 28% reduction in the odds of cerebral stroke (OR, 0.72; 95% CI, 0.56-0.92; P = .009; I2 = 0%). A significant relationship between patient risk profile and benefits from OPCAB was found in terms of all-cause mortality ( P < .01), MI ( P < .01), and cerebral stroke ( P < .01). Conclusions OPCAB is associated with a significant reduction in the odds of cerebral stroke compared with conventional CABG. In addition, benefits of OPCAB in terms of death, MI, and cerebral stroke are significantly related to patient risk profile, suggesting that OPCAB should be strongly considered in high-risk patients.
Background The debate on the relative benefits of off-pump and on-pump coronary artery bypass surgery ( OPCABG and ONCABG ) is still open. We aimed to provide an updated and complete summary of the ...evidence on the differences between OPCABG and ONCABG and to explore whether the length of the follow-up and the surgeons' experience in OPCABG modify the comparative results. Methods and Results All randomized clinical trials comparing OPCABG and ONCABG were included. Primary outcome was follow-up mortality. Secondary outcomes were operative mortality, perioperative stroke, perioperative myocardial infarction, and late repeated revascularization. Subgroup analyses were performed based on the length of the follow-up and the percentage of crossover from the OPCABG group (used as a surrogate of surgeon experience with OPCABG ). One hundred four trials were included (20 627 patients, OPCABG : 10 288; ONCABG : 10 339). Weighted mean follow-up time was 3.7 years (range 1-7.5 years). OPCABG was associated with a higher risk of follow-up mortality (incidence rate ratio 1.11, 95% confidence interval 1.00-1.23, P=0.05). The difference was significant only for trials with mean follow-up of ≥3 years and for studies with a crossover rate of ≥10%. There was a trend toward lower risk of perioperative stroke and higher need for late repeated revascularization in the OPCABG arm. Conclusions OPCABG is associated with a higher incidence of incomplete revascularization, an increased need for repeated revascularization, and decreased midterm survival compared with ONCABG . Surgeon inexperience in OPCABG is associated with late mortality.
Objective Our objective was to compare off-pump coronary artery bypass surgery carried out via a left anterolateral thoracotomy (ThoraCAB) or via a conventional median sternotomy (OPCAB). Background ...Recent advances in minimally invasive cardiac surgery have extended the technique to allow complete surgical revascularization on the beating heart via thoracotomy. Methods Patients undergoing nonemergency primary surgery were enrolled between February 2007 and September 2009 at 2 centers. The primary outcome was the time from surgery to fitness for hospital discharge as defined by objective criteria. Results A total of 93 patients were randomized to off-pump coronary artery bypass surgery via a median sternotomy (OPCAB) and 91 to off-pump coronary artery bypass surgery via a left anterolateral thoracotomy (ThoraCAB). The surgery was longer for patients in the ThoraCAB group (median, 4.1 vs 3.3 hours) and there were fewer with more than 3 grafts (2% vs 17%). The median time from surgery to fitness for discharge was 6 days (interquartile range, 4-7) in the ThoraCAB group versus 5 days (interquartile range, 4-7) in the OPCAB group ( P = .53). The intubation time was shorter, by on average 65 minutes, in the ThoraCAB group ( P = .017), although the time in intensive care was similar ( P = .91). Pain scores were similar ( P = .97), but more analgesia was required in the ThoraCAB group (median duration, 38.8 vs 35.5 hours, P < .001; tramadol use, 66% vs 49%, P = .024). ThoraCAB was associated with significantly worse lung function at discharge (average difference, −0.25 L, P = .01) but quality of life scores at 3 and 12 months were similar ( P = .52). The average total cost was 10% higher with ThoraCAB ( P = .007). Conclusions ThoraCAB resulted in no overall clinical benefit relative to OPCAB.
Varying definitions of procedural myocardial infarction (PMI) are in widespread use.
This study sought to determine the rates and clinical relevance of PMI using different definitions in patients ...with left main coronary artery disease randomized to percutaneous coronary intervention (PCI) versus coronary artery bypass grafting (CABG) surgery in the EXCEL (Evaluation of XIENCE versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial.
The pre-specified protocol definition of PMI (PMIProt) required a large elevation of creatine kinase-MB (CK-MB), with identical threshold for both procedures. The Third Universal Definition of MI (types 4a and 5) (PMIUD) required lesser biomarker elevations but with supporting evidence of myocardial ischemia, different after PCI and CABG. For the PMIUD, troponins were used preferentially (available in 49.5% of patients), CK-MB otherwise. The multivariable relationship between each PMI type and 5-year mortality was determined.
PMIProt occurred in 34 of 935 (3.6%) patients after PCI and 56 of 923 (6.1%) patients after CABG (difference −2.4%; 95% confidence interval CI: −4.4% to −0.5%; p = 0.015). The corresponding rates of PMIUD were 37 (4.0%) and 20 (2.2%), respectively (difference 1.8%; 95% CI: 0.2% to 3.4%; p = 0.025). Both PMIProt and PMIUD were associated with 5-year cardiovascular mortality (adjusted hazard ratio HR: 2.18 95% CI: 1.13 to 4.23 and 2.87 95% CI: 1.44 to 5.73, respectively). PMIProt was associated with a consistent hazard of cardiovascular mortality after both PCI and CABG (pinteraction = 0.86). Conversely, PMIUD was strongly associated with cardiovascular mortality after CABG (adjusted HR: 11.94; 95% CI: 4.84 to 29.47) but not after PCI (adjusted HR: 1.14; 95% CI: 0.35 to 3.67) (pinteraction = 0.004). Results were similar for all-cause mortality and with varying PMIUD biomarker definitions. Only large biomarker elevations (CK-MB ≥10× upper reference limit and troponin ≥70× upper reference limit) were associated with mortality.
The rates of PMI after PCI and CABG vary greatly with different definitions. In the EXCEL trial, the pre-specified PMIProt was associated with similar hazard after PCI and CABG, whereas PMIUD was strongly associated with mortality after CABG but not after PCI. (EXCEL Clinical Trial EXCEL; NCT01205776)
Display omitted
Abstract
OBJECTIVES
Robotic off-pump totally endoscopic coronary artery bypass (TECAB) is the least invasive form of surgical coronary revascularization. It has proved to be highly effective and ...safe. Its benefits are well-established and include fewer complications, shorter hospital stay and quicker return to normal activities. TECAB has undergone 2 decades of technological advancement to include multivessel grafting, a beating-heart approach and successful completion in multiple patient groups in experienced hands. The aim of this report was to examine outcomes of robotic off-pump TECAB at our institution over 7 years.
METHODS
Data from 544 patients undergoing TECAB between July 2013 and August 2020 were retrospectively examined. The C-Port Flex-A distal anastomotic device was used for the majority of grafts (70%). Yearly follow-up was conducted. Angiographic early patency data were reviewed for patients undergoing hybrid revascularization.
RESULTS
The mean age was 66 years, with 1.7% mean STS risk. Fifty-six percentage had multivessel TECAB. There was 1 conversion to sternotomy, and 46% extubation in the Operating Room (OR). Mortality was 0.9%. Early graft patency was 97%. At mid-term follow-up at 38 months, cardiac mortality was 2.7% and freedom from major adverse cardiac events was 92.5%.
CONCLUSIONS
We conclude that robotic beating-heart TECAB in the current era is safe and effective with excellent outcomes and comparable early angiographic patency to standard coronary artery bypass grafting surgery when performed frequently by an experienced team. This procedure was completed in our hands both with and without an anastomotic device. Longer-term studies are warranted.
Robotic off-pump totally endoscopic coronary artery bypass (TECAB) is the least invasive form of surgical coronary revascularization.