Guidance is needed to help clinicians decide which out-of-center (OOC) testing devices are appropriate for diagnosing obstructive sleep apnea (OSA). A new classification system that details the type ...of signals measured by these devices is presented. This proposed system categorizes OOC devices based on measurements of Sleep, Cardiovascular, Oximetry, Position, Effort, and Respiratory (SCOPER) parameters.Criteria for evaluating the devices are also presented, which were generated from chosen pre-test and post-test probabilities. These criteria state that in patients with a high pretest probability of having OSA, the OOC testing device has a positive likelihood ratio (LR+) of 5 or greater coinciding with an in-lab-polysomnography (PSG)-generated apnea hypopnea index (AHI) ≥ 5, and an adequate sensitivity (at least 0.825).Since oximetry is a mandatory signal for scoring AHI using PSG, devices that do not incorporate oximetry were excluded. English peer-reviewed literature on FDA-approved devices utilizing more than 1 signal was reviewed according to the above criteria for 6 questions. These questions specifically addressed the adequacy of different respiratory and effort sensors and combinations thereof to diagnose OSA. In summary, the literature is currently inadequate to state with confidence that a thermistor alone without any effort sensor is adequate to diagnose OSA; if a thermal sensing device is used as the only measure of respiration, 2 effort belts are required as part of the montage and piezoelectric belts are acceptable in this context; nasal pressure can be an adequate measurement of respiration with no effort measure with the caveat that this may be device specific; nasal pressure may be used in combination with either 2 piezoelectric or respiratory inductance plethysmographic (RIP) belts (but not 1 piezoelectric belt); and there is insufficient evidence to state that both nasal pressure and thermistor are required to adequately diagnose OSA. With respect to alternative devices for diagnosing OSA, the data indicate that peripheral arterial tonometry (PAT) devices are adequate for the proposed use; the device based on cardiac signals shows promise, but more study is required as it has not been tested in the home setting; for the device based on end-tidal CO(2) (ETCO(2)), it appears to be adequate for a hospital population; and for devices utilizing acoustic signals, the data are insufficient to determine whether the use of acoustic signals with other signals as a substitute for airflow is adequate to diagnose OSA.Standardized research is needed on OOC devices that report LR+ at the appropriate AHI (≥ 5) and scored according to the recommended definitions, while using appropriate research reporting and methodology to minimize bias.
Appropriate interpretation of pulmonary function tests (PFTs) involves the classification of observed values as within/outside the normal range based on a reference population of healthy individuals, ...integrating knowledge of physiological determinants of test results into functional classifications and integrating patterns with other clinical data to estimate prognosis. In 2005, the American Thoracic Society (ATS) and European Respiratory Society (ERS) jointly adopted technical standards for the interpretation of PFTs. We aimed to update the 2005 recommendations and incorporate evidence from recent literature to establish new standards for PFT interpretation.
This technical standards document was developed by an international joint Task Force, appointed by the ERS/ATS with multidisciplinary expertise in conducting and interpreting PFTs and developing international standards. A comprehensive literature review was conducted and published evidence was reviewed.
Recommendations for the choice of reference equations and limits of normal of the healthy population to identify individuals with unusually low or high results are discussed. Interpretation strategies for bronchodilator responsiveness testing, limits of natural changes over time and severity are also updated. Interpretation of measurements made by spirometry, lung volumes and gas transfer are described as they relate to underlying pathophysiology with updated classification protocols of common impairments.
Interpretation of PFTs must be complemented with clinical expertise and consideration of the inherent biological variability of the test and the uncertainty of the test result to ensure appropriate interpretation of an individual's lung function measurements.
Inert gas washout tests, performed using the single- or multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer ...complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. These benefits have led to a resurgence of interest in these techniques from manufacturers, clinicians and researchers, yet detailed guidelines for washout equipment specifications, test performance and analysis are lacking. This manuscript provides recommendations about these aspects, applicable to both the paediatric and adult testing environment, whilst outlining the important principles that are essential for the reader to understand. These recommendations are evidence based, where possible, but in many places represent expert opinion from a working group with a large collective experience in the techniques discussed. Finally, the important issues that remain unanswered are highlighted. By addressing these important issues and directing future research, the hope is to facilitate the incorporation of these promising tests into routine clinical practice.
The infectious coronavirus disease 2019 (COVID-19) pandemic is an ongoing global healthcare challenge. Up to one-third of hospitalised patients develop severe pulmonary complications and acute ...respiratory distress syndrome. Pulmonary outcomes following COVID-19 are unknown.
The Swiss COVID-19 lung study is a multicentre prospective cohort investigating pulmonary sequelae of COVID-19. We report on initial follow-up 4 months after mild/moderate or severe/critical COVID-19 according to the World Health Organization severity classification.
113 COVID-19 survivors were included (mild/moderate n=47, severe/critical n=66). We confirmed several comorbidities as risk factors for severe/critical disease. Severe/critical disease was associated with impaired pulmonary function,
diffusing capacity of the lung for carbon monoxide (
) % predicted, reduced 6-min walk distance (6MWD) and exercise-induced oxygen desaturation. After adjustment for potential confounding by age, sex and body mass index (BMI), patients after severe/critical COVID-19 had a
20.9% pred (95% CI 12.4-29.4% pred, p=0.01) lower at follow-up.
% pred was the strongest independent factor associated with previous severe/critical disease when age, sex, BMI, 6MWD and minimal peripheral oxygen saturation at exercise were included in the multivariable model (adjusted odds ratio per 10% predicted 0.59, 95% CI 0. 37-0.87; p=0.01). Mosaic hypoattenuation on chest computed tomography at follow-up was significantly associated with previous severe/critical COVID-19 including adjustment for age and sex (adjusted OR 11.7, 95% CI 1.7-239; p=0.03).
4 months after severe acute respiratory syndrome coronavirus 2 infection, severe/critical COVID-19 was associated with significant functional and radiological abnormalities, potentially due to small-airway and lung parenchymal disease. A systematic follow-up for survivors needs to be evaluated to optimise care for patients recovering from COVID-19.
Increasing awareness of the prevalence and significance of Preserved Ratio Impaired Spirometry (PRISm), alternatively known as restrictive or Global Initiative for Chronic Obstructive Lung Disease ...(GOLD)-unclassified spirometry, has expanded the body of knowledge on cross-sectional risk factors. However, longitudinal studies of PRISm remain limited.
To examine longitudinal patterns of change in lung function, radiographic characteristics, and mortality of current and former smokers with PRISm.
Current and former smokers, aged 45 to 80 years, were enrolled in COPDGene (phase 1, 2008-2011) and returned for a 5-year follow-up (phase 2, 2012-2016). Subjects completed questionnaires, spirometry, chest computed tomography scans, and 6-minute-walk tests at both study visits. Baseline characteristics, longitudinal change in lung function, and mortality were assessed by post-bronchodilator lung function categories: PRISm (FEV
/FVC < 0.7 and FEV
< 80%), GOLD0 (FEV
/FVC > 0.7 and FEV
> 80%), and GOLD1-4 (FEV
/FVC < 0.7).
Although the prevalence of PRISm was consistent (12.4-12.5%) at phases 1 and 2, subjects with PRISm exhibited substantial rates of transition to and from other lung function categories. Among subjects with PRISm at phase 1, 22.2% transitioned to GOLD0 and 25.1% progressed to GOLD1-4 at phase 2. Subjects with PRISm at both phase 1 and phase 2 had reduced rates of FEV
decline (-27.3 ± 42.1 vs. -33.0 ± 41.7 ml/yr) and comparable proportions of normal computed tomography scans (51% vs. 52.7%) relative to subjects with stable GOLD0 spirometry. In contrast, incident PRISm exhibited accelerated rates of lung function decline. Subjects with PRISm at phase 1 had higher mortality rates relative to GOLD0 and lower rates relative to the GOLD1-4 group.
PRISm is highly prevalent, is associated with increased mortality, and represents a transitional state for significant subgroups of subjects. Additional studies to characterize longitudinal progression in PRISm are warranted.
The impact of intraoperative ventilation on postoperative pulmonary complications is not defined. The authors aimed at determining the effectiveness of protective mechanical ventilation during open ...abdominal surgery on a modified Clinical Pulmonary Infection Score as primary outcome and postoperative pulmonary function.
Prospective randomized, open-label, clinical trial performed in 56 patients scheduled to undergo elective open abdominal surgery lasting more than 2 h. Patients were assigned by envelopes to mechanical ventilation with tidal volume of 9 ml/kg ideal body weight and zero-positive end-expiratory pressure (standard ventilation strategy) or tidal volumes of 7 ml/kg ideal body weight, 10 cm H2O positive end-expiratory pressure, and recruitment maneuvers (protective ventilation strategy). Modified Clinical Pulmonary Infection Score, gas exchange, and pulmonary functional tests were measured preoperatively, as well as at days 1, 3, and 5 after surgery.
Patients ventilated protectively showed better pulmonary functional tests up to day 5, fewer alterations on chest x-ray up to day 3 and higher arterial oxygenation in air at days 1, 3, and 5 (mmHg; mean ± SD): 77.1 ± 13.0 versus 64.9 ± 11.3 (P = 0.0006), 80.5 ± 10.1 versus 69.7 ± 9.3 (P = 0.0002), and 82.1 ± 10.7 versus 78.5 ± 21.7 (P = 0.44) respectively. The modified Clinical Pulmonary Infection Score was lower in the protective ventilation strategy at days 1 and 3. The percentage of patients in hospital at day 28 after surgery was not different between groups (7 vs. 15% respectively, P = 0.42).
A protective ventilation strategy during abdominal surgery lasting more than 2 h improved respiratory function and reduced the modified Clinical Pulmonary Infection Score without affecting length of hospital stay.
Identification of pathologic changes in early and mild obstructive lung disease has shown the importance of the small airways and their contribution to symptoms. Indeed, significant small airways ...dysfunction has been found prior to any overt airway obstruction being detectable by conventional spirometry techniques. However, most therapies for the treatment of obstructive lung disease target the physiological changes and associated symptoms that result from chronic lung disease, rather than directly targeting the specific underlying causes of airflow disruption or the drivers of disease progression. In addition, although spirometry is the current standard for diagnosis and monitoring of response to therapy, the most widely used measure, FEV1 , does not align with the pathologic changes in early or mild disease and may not align with symptoms or exacerbation frequency in the individual patient. Newer functional and imaging techniques allow more effective assessment of small airways dysfunction; however, significant gaps in our understanding remain. Improving our knowledge of the role of small airways dysfunction in early disease in the airways, along with the identification of novel end points to measure subclinical changes in this region (ie, those not captured as symptoms or identified through standard FEV1), may lead to the development of novel therapies that directly combat early airways disease processes with a view to slowing disease progression and reversing damage. This expert opinion paper discusses small airways disease in the context of asthma and COPD and highlights gaps in current knowledge that impede earlier identification of obstructive lung disease and the development and standardization of novel small airways-specific end points for use in clinical trials.