Vascularized composite allografts, particularly hand and forearm, have limited ischemic tolerance after procurement. In bilateral hand transplantations, this demands a 2 team approach and expedited ...transfer of the allograft, limiting the recovery to a small geographic area. Ex situ perfusion may be an alternative allograft preservation method to extend allograft survival time. This is a short report of 5 human limbs maintained for 24 hours with ex situ perfusion.
Upper limbs were procured from brain-dead organ donors. Following recovery, the brachial artery was cannulated and flushed with 10 000 U of heparin. The limb was then attached to a custom-made, near-normothermic (30-33°C) ex situ perfusion system composed of a pump, reservoir, and oxygenator. Perfusate was plasma-based with a hemoglobin concentration of 4 to 6 g/dL.
Average warm ischemia time was 76 minutes. Perfusion was maintained at an average systolic pressure of 93 ± 2 mm Hg, flow 310 ± 20 mL/min, and vascular resistance 153 ± 16 mm Hg/L per minute. Average oxygen consumption was 1.1 ± 0.2 mL/kg per minute. Neuromuscular electrical stimulation continually displayed contraction until the end of perfusion, and histology showed no myocyte injury.
Human limb allografts appeared viable after 24 hours of near-normothermic ex situ perfusion. Although these results are early and need validation with transplantation, this technology has promise for extending allograft storage times.
•Planar quantification in lung perfusion scan underestimates perfusion fraction of upper lobes•3D-quantitated SPECT could change operability in upper lobe lesions from operable to inoperable•Lung ...resections should be possible based on 3D- SPECT in lower lobe tumors with borderline lung function
Based on previous studies, single-photon emission computed tomography/computed tomography (SPECT/CT) has been proven more accurate and reproducible than planar lung perfusion scintigraphy to assess lobar perfusion. However, the impact of 3D-quantitated SPECT/CT on intended management in functionally marginal candidates for pulmonary resection is unknown. The evaluation of this impact was the main aim of this study.
Consecutive candidates for lung resection underwent preoperative evaluation according to ERS/ESTS Algorithm and underwent preoperative lung perfusion imaging. The lobar contribution to the total lung perfusion was estimated using established planar scintigraphic methods and three-dimensional quantitative SPECT/CT method (CT Pulmo3D and xSPECT-Quant, Siemens). The difference in estimated lobar perfusion with resulting changes in predicted post-operative (ppo) lung function and extent of lung resection were analyzed to reveal possible changes in operability. In-hospital outcome was assessed.
One hundred twenty patients (46 females) were enrolled. The mean age (±SD) of patients was 68±9 years, target lesions were in upper lobes in 57.7% and in lower lobes in 33.5%. The median FEV1 (forced expiratory volume in 1 second) was 70.5% IQR 52-84 and median DLCO (diffusion capacity of lung for carbon monoxide) was 56.6% 47.1-67.4. The planar posterior oblique method, compared to 3D-quantitated SPECT/CT, underestimated the perfusion of upper lobes by a median difference of 5% (right 2-9, left 2.5-8; p=<0.0001), while it overestimated the perfusion of lower lobes (left by 4% 2-7, right by 6%2-9; p=<0.0001). In contrast to planar scintigraphy-based evaluation, 4 patients (3.3%), all with upper lobe lesions, were classified as inoperable when 3D-quantitated SPECT/CT was used for calculation of the ppo lung function.
In selected patients with upper lobe lesions, 3D-quantitated SPECT/CT would have changed the treatment strategy from operable to inoperable. Importantly, post-operative mortality in this particular subgroup was disproportionally high. 3D-quantitated SPECT/CT shall be further evaluated as it might improve preoperative risk stratification in functionally marginal candidates.
The impact of 3D-quantitated SPECT/CT on intended management in functionally marginal candidates for pulmonary resection is unknown. The planar posterior oblique method, compared to 3D-quantitated SPECT/CT, underestimated the perfusion of upper lobes, while it overestimated the perfusion of lower lobes. 3D-quantitated SPECT/CT shall be further evaluated as it might improve preoperative risk stratification in functionally marginal candidates.
Standard US practice for donation after circulatory death (DCD) abdominal organ procurement is superrapid recovery (SRR). A newer approach using thoracoabdominal normothermic regional perfusion ...(TA-NRP) shows promise for better recipient outcomes for all organs, but there are few reports of abdominal recipient outcomes from TA-NRP donors. We used the United Network for Organ Sharing data to identify all cardiac DCD donors from October 1, 2020, to May 20, 2022, and categorized them by recovery procedure (SRR vs TA-NRP). We then identified all liver, kidney, and pancreas recipients of these donors for whom 6-month outcome data were available and compared patient and graft survival, kidney delayed graft function (DGF), and biliary complications between TA-NRP DCD and SRR DCD organ recipients. Patient and graft survival did not differ significantly between groups for either kidney or liver recipients. Significantly fewer TA-NRP kidney recipients developed DGF (12.7% 15/118 vs 42.0% 84/200, P <.001), and TA-NRP and pumped kidneys had lower odds for DGF on multivariate analysis. No liver recipients in either group had biliary complications or were relisted for transplantation for ischemic cholangiopathy. Although long-term outcomes need to be investigated, our early results show similar outcomes for recipients of TA-NRP DCD abdominal organs versus recipients of SRR DCD abdominal organs. We believe that TA-NRP is an effective approach to expand the use of DCD organs.
Summary
Normothermic regional perfusion (NRP) in donation after circulatory death (DCD) is a safe alternative to in situ cooling and rapid procurement. An increasing number of countries and centres ...are performing NRP, a technically and logistically challenging procedure. This consensus document provides evidence‐based recommendations on the use of NRP in uncontrolled and controlled DCDs. It also offers minimal ethical, logistical and technical requirements that form the foundation of a safe and effective NRP programme. The present article is based on evidence and opinions formulated by a panel of European experts of Workstream 04 of the Transplantation Learning Journey project, which is part of the European Society for Organ Transplantation.
Normothermic regional perfusion (NRP) in donation after circulatory death (DCD) is a safe alternative to in situ cooling and rapid procurement. This consensus document provides evidence‐based recommendations on the use of NRP in uncontrolled and controlled DCDs. It also offers minimal ethical, logistical and technical requirements that form the foundation of a safe and effective NRP programme. The present article is based on evidence and opinions formulated by a panel of European experts of Workstream 04 of the Transplantation Learning Journey project, which is part of the European Society for Organ Transplantation.
These guidelines update the previous EANM 2009 guidelines on the diagnosis of pulmonary embolism (PE). Relevant new aspects are related to (a) quantification of PE and other ventilation/perfusion ...defects; (b) follow-up of patients with PE; (c) chronic PE; and (d) description of additional pulmonary physiological changes leading to diagnoses of left ventricular heart failure (HF), chronic obstructive pulmonary disease (COPD) and pneumonia. The diagnosis of PE should be reported when a mismatch of one segment or two subsegments is found. For ventilation, Technegas or krypton gas is preferred over diethylene triamine pentaacetic acid (DTPA) in patients with COPD. Tomographic imaging with V/P
SPECT
has higher sensitivity and specificity for PE compared with planar imaging. Absence of contraindications makes V/P
SPECT
an essential method for the diagnosis of PE. When V/P
SPECT
is combined with a low-dose CT, the specificity of the test can be further improved, especially in patients with other lung diseases. Pitfalls in V/P
SPECT
interpretation are discussed. In conclusion, V/P
SPECT
is strongly recommended as it accurately establishes the diagnosis of PE even in the presence of diseases like COPD, HF and pneumonia and has no contraindications.
Mechanical thrombectomy (MT) is the recommended treatment for acute ischemic stroke caused by anterior circulation large vessel occlusion. However, despite a high rate of reperfusion, the clinical ...response to successful MT remains highly variable in the early time window where optimal imaging selection criteria have not been established. We hypothesize that the baseline perfusion imaging profile may help forecast the clinical response to MT in this setting.
We conducted a prospective multicenter cohort study of patients with large vessel occlusion-related acute ischemic stroke treated by MT within 6 hours. Treatment decisions and the modified Rankin Scale evaluation at 3 months were performed blinded to the results of baseline perfusion imaging. Study groups were defined a posteriori based on predefined imaging profiles: target mismatch (TMM; core volume <70 mL/mismatch ratio >1.2 and mismatch volume >10 mL) versus no TMM or mismatch (MM; mismatch ratio >1.2 and volume >10 mL) versus no MM. Functional recovery (modified Rankin Scale, 0-2) at 3 months was compared based on imaging profile at baseline and whether reperfusion (modified Thrombolysis in Cerebral Infarction 2bc3) was achieved.
Two hundred eighteen patients (mean age, 71±15 years; median National Institutes of Health Stroke Scale score, 17 interquartile range, 12-21) were enrolled. Perfusion imaging profiles were 71% TMM and 82% MM. The rate of functional recovery was 54% overall. Both TMM and MM profiles were independently associated with a higher rate on functional recovery at 3 months Adjusted odds ratios were 3.3 (95% CI, 1.4-7.9) for TMM and 5.9 (95% CI, 1.8-19.6) for MM. Reperfusion (modified Thrombolysis in Cerebral Infarction 2bc3) was achieved in 86% and was more frequent in TMM and MM patients. Reperfusion was associated with a higher rate of functional recovery in MM and TMM patients but not among those with no MM.
In this cohort study, about 80% of the patients with a large vessel occlusion-related acute ischemic stroke had evidence of penumbra, regardless of infarction volume. Perfusion imaging profiles predict the clinical response to MT.
The fast and accurate assessment of cerebral perfusion is fundamental for the diagnosis and successful treatment of stroke patients. Magnetic particle imaging (MPI) is a new radiation-free ...tomographic imaging method with a superior temporal resolution, compared to other conventional imaging methods. In addition, MPI scanners can be built as prehospital mobile devices, which require less complex infrastructure than computed tomography (CT) and magnetic resonance imaging (MRI). With these advantages, MPI could accelerate the stroke diagnosis and treatment, thereby improving outcomes. Our objective was to investigate the capabilities of MPI to detect perfusion deficits in a murine model of ischemic stroke. Cerebral ischemia was induced by inserting of a microfilament in the internal carotid artery in C57BL/6 mice, thereby blocking the blood flow into the medial cerebral artery. After the injection of a contrast agent (superparamagnetic iron oxide nanoparticles) specifically tailored for MPI, cerebral perfusion and vascular anatomy were assessed by the MPI scanner within seconds. To validate and compare our MPI data, we performed perfusion imaging with a small animal MRI scanner. MPI detected the perfusion deficits in the ischemic brain, which were comparable to those with MRI but in real-time. For the first time, we showed that MPI could be used as a diagnostic tool for relevant diseases in vivo, such as an ischemic stroke. Due to its shorter image acquisition times and increased temporal resolution compared to that of MRI or CT, we expect that MPI offers the potential to improve stroke imaging and treatment.
The purpose of this study is to obtain the reference range of peripheral perfusion index (PPI) of asymptomatic well newborns at 6 to 72 h of life at different altitudes. A population-based ...prospective cohort study was conducted in cities at different altitudes in China. Asymptomatic well newborns were enrolled consecutively from six hospitals with an altitude of 4 to 4200 m between February 1, 2020, and April 15, 2021. PPI was measured at 6, 12, 24, 48, and 72 h after birth on the right hand (pre-ductal) and either foot (post-ductal) using a Masimo SET Radical-7 oximeter. Fiftieth percentile reference curves of the pre- and post-ductal PPI values at 6–72 h after birth were generated using the Lambda Mu Sigma method. Linear mixed-effects regression was performed to determine the influence of different altitude levels on PPI values over different measurement time points. A total of 4257 asymptomatic well newborns were recruited for analysis. The median and quartile pre- and post-ductal PPI values at 6–72 h of life at different altitudes were 1.70 (1.20, 2.60) and 1.70 (1.10, 2.70) for all infants, 1.30 (1.10, 1.90) and 1.10 (0.88, 1.80) for infants at low altitude, 1.40 (1.00, 2.00) and 1.30 (0.99, 2.00) at mild altitudes, 1.90 (1.30, 2.50) and 1.80 (1.20, 2.70) at moderate altitudes, 1.80 (1.40, 3.50) and 2.20 (1.60, 4.30) for high altitudes, 3.20 (2.70, 3.70), and 3.10 (2.10, 3.30) for higher altitudes, respectively. Overall, both pre- and post-ductal PPI increased with altitude. The 50th percentile curves of pre- and post-ductal PPI values in well newborns at mild, low, moderate, and high altitudes were relatively similar, while the difference between the PPI curves of infants at higher altitudes and other altitudes was significantly different.
Conclusions
: With the increase of altitude, pre- and post-ductal PPI of newborns increases. Our study obtained the PPI reference values of asymptomatic well newborns at 6 to 72 h after birth at different altitudes from 4 to ≥ 4000 m.
What is Known:
• Monitoring hemodynamics is very important to neonates. As an accurate and reliable hemodynamic monitoring index, PPI can detect irreversible damage caused by insufficient tissue perfusion and oxygenation early, directly, noninvasively, and continuously.
What is New:
• Our study obtained the PPI reference values of asymptomatic well newborns at 6 to 72 h after birth at different altitudes from 4 to ≥ 4000 m. With the increase of altitude, pre- and post-ductal PPI of newborns increase with statistical significance. Therefore, the values and disease thresholds of PPI for asymptomatic neonates should be modified according to altitudes.