E-resources
Peer reviewed
-
Sobhani, Nasim C.; Goemans, Sophie; Nguyen, Antoinette; Chambers, Melissa E.; Richley, Michael; Gabby, Lauryn C.; Field, Nancy; Han, Christina S.; Ramos, Gladys A.
American journal of obstetrics and gynecology, 2024-Jan-17Journal Article
Continuous glucose monitors provide detailed information regarding glycemic control in pregnant patients with type 1 diabetes. Little data have been published examining the association between continuous glucose monitor parameters and perinatal outcomes among gravidas with type 1 diabetes using continuous glucose monitors. This study aimed to examine the association between perinatal outcomes and time-in-range as assessed by continuous glucose monitors used in pregnant individuals with type 1 diabetes. We hypothesized that higher time-in-range would be associated with lower risk of adverse perinatal outcomes. This multicenter retrospective cohort study included all gravidas with type 1 diabetes using continuous glucose monitors who delivered from 2020 to 2022 at 5 University of California sites. Only those with continuous glucose monitor target range set to 70 to 140 mg/dL (±10 mg/dL) were included. Time-in-range (%) was recorded at 12, 16, 20, 24, 28, and 32 weeks. The primary maternal and neonatal outcomes were preeclampsia and large for gestational age, defined as birthweight ≥95th percentile. Kruskal–Wallis tests were used to compare median time-in-range between those with and without the primary outcomes. Log-binomial regression was used to obtain risk ratios, with adjustment for microvascular disease and years with type 1 diabetes. A total of 91 patients were included. Most used an insulin pump (81%) and did not have diabetic microvascular disease (72%). Median time since diagnosis of type 1 diabetes was 16 years, and median periconception hemoglobin A1c was 6.7%. Compared with those with preeclampsia, normotensive gravidas had significantly higher time-in-range at nearly every time point. A similar pattern was observed for those with normal-birthweight infants compared with large-for-gestational-age infants. On adjusted analyses, every 5-unit increase in time-in-range at 12 weeks was associated with 45% and 46% reductions in the risks of preeclampsia and large for gestational age, respectively (preeclampsia: adjusted risk ratio, 0.55; 95% confidence interval, 0.30–0.99; large for gestational age: adjusted risk ratio, 0.54; 95% confidence interval, 0.29–0.99). Higher time-in-range is associated with lower risk of preeclampsia and large for gestational age. This association is observed early in gestation, when each 5-unit increase in time-in-range is associated with ∼50% reduction in the risk of these complications. These findings can be used to counsel patients regarding the risk of pregnancy complications at specific time-in-range values, and to encourage patients that even small improvements in time-in-range can have significant impact on pregnancy outcomes. Larger studies are needed to further explore these findings and to identify optimal time-in-range to reduce perinatal complication rates. Display omitted
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.