E-resources
Peer reviewed
Open access
-
Gupta, Charu; Agarwal, Payal; Mehta, Shubha; Gupta, AK; Shroff, CyrusM
Journal of Clinical Ophthalmology and Research, 2018, Volume: 6, Issue: 2Journal Article
Aim: The aim of this study is to comparatively evaluate “internal limiting membrane (ILM) blue (0.025% brilliant blue G (BBG) +4% polyethylene glycol” and “Brilliant Peel (0.025% BBG + heavy water)” in idiopathic full-thickness macular hole (FTMH) surgery with respect to anatomical and functional outcome and surgical ease of ILM peeling. Materials and Methods: It was a prospective comparative study. Thirty patients with idiopathic FTMH selected for pars-plana vitrectomy with ILM peeling were included in the study. Cataract extraction was combined with vitrectomy if cataract was significant. Fifteen eyes underwent ILM peeling with ILM blue – Group 1 and fifteen eyes with Brilliant Peel – Group 2. The adequacy of ILM staining was noted intraoperatively. All patients followed up next day, at 1 week, 6 weeks, and 3 months. Macular hole closure rate and gain in visual acuity (VA) and contrast sensitivity (CS) were noted. Statistical Analysis: Student's t-test was used to assess the baseline numeric differences among groups. Repeated measures ANOVA was used to assess VA improvement over time in each group. Chi-square test was used to compare two groups in terms of stage of macular hole. Means test was used to check the effect of lens status in visual recovery. Results: Both groups were well matched in demographic data, baseline VA, stage of macular hole, and percentage of eyes undergoing simultaneous cataract extraction. Macular hole closed in 100% of eyes. Mean pre- and postoperative logMAR best-corrected VA was 0.80 and 0.40 in ILM blue group and 0.993 and 0.527 in the Brilliant Peel group. VA improvement was clinically and statistically significant in both ILM blue (P = 0.004) and Brilliant Peel (P = 0.003) groups. The groups did not differ from each other at 3 months in terms of gain in VA (P = 0.291) and CS. Intraoperatively, both the dyes stained the ILM well. Conclusion: ILM peeling with ILM blue and Brilliant Peel dyes showed comparable intraoperative staining and good postoperative anatomic and functional outcome.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.