The aim of this pilot study was to evaluate the accuracy and predictability of a splintless treatment protocol for edentulous patients undergoing orthognathic surgery in four consecutive cases. All ...operations were virtually planned, followed by computer-aided design of individual osteotomy guides and patient-specific fixation implants, which were three-dimensionally printed in titanium. In order to evaluate the discrepancy between the planned and the achieved postoperative result, the postoperative outcome was compared to the virtual treatment plan. Rotational and translational movement and discrepancies with the planned movements were quantified for the maxilla; the advancement was quantified for the mandible. For the maxilla, there was a mean translation discrepancy of 0.6mm. With regard to rotation, there was a mean discrepancy of 1.9°, 0.1°, and 0.4° for pitch, yaw, and roll, respectively. The mean discrepancy in translation of the mandible was 0.4mm. The results of this pilot study indicate that the splintless treatment protocol for orthognathic surgery in edentulous patients presented here is accurate and predictable.
The accuracy of intra-operative navigation is largely dependent on the intra-operative registration procedure. Next to accuracy, important factors to consider for the registration procedure are ...invasiveness, time consumption, logistical demands, user-dependency, compatibility and radiation exposure. In this study, a workflow is presented that eliminates the need for a registration procedure altogether: registration-free navigation. In the workflow, the maxillary dental model is fused to the pre-operative imaging data using commercially available virtual planning software. A virtual Dynamic Reference Frame on a splint is designed on the patient's fused maxillary dentition: during surgery, the splint containing the reference frame is positioned on the patient's dentition. This alleviates the need for any registration procedure, since the position of the reference frame is known from the design. The accuracy of the workflow was evaluated in a cadaver set-up, and compared to bone-anchored fiducial, virtual splint and surface-based registration. The results showed that accuracy of the workflow was greatly dependent on tracking technique used: the workflow was the most accurate with electromagnetic tracking, but the least accurate with optical tracking. Although this method offers a time-efficient, non-invasive, radiation-free automatic alternative for registration, clinical implementation is hampered by the unexplained differences in accuracy between tracking techniques.
The aim of this study was to evaluate a novel soft tissue-based method to register an intraoral scan (IOS) with a cone beam computed tomography (CBCT) scan. IOS and CBCT data were obtained from eight ...dentate patients (mean age 21±2 years; three male, five female) and 14 fully edentulous patients (mean age 56±9 years; eight male, six female). An algorithm was developed to create a soft tissue model of the CBCT scan, which allowed a soft tissue-based registration to be performed with the IOS. First, validation was performed on dentate jaws with registration of the palatal mucosal surface and accuracy evaluation at the level of the teeth. Second, fully edentulous jaws were registered using both the palatal and alveolar crest mucosal surfaces. Distance maps were created to measure the method accuracy. The mean registration error was 0.49±0.26mm for the dentate jaws. Registration of the fully edentulous jaws had a mean error of 0.16±0.08mm at the palate and 0.16±0.05mm at the alveolar crest. In conclusion, the high accuracy of this registration method may allow the digital workflow to be optimized when no teeth are available to perform a regular registration procedure.
Purpose
The purpose of this study was to evaluate the clinical accuracy of the fusion of intra-oral scans in cone-beam computed tomography (CBCT) scans using two commercially available software ...packages.
Materials and methods
Ten dry human skulls were subjected to structured light scanning, CBCT scanning, and intra-oral scanning. Two commercially available software packages were used to perform fusion of the intra-oral scans in the CBCT scan to create an accurate virtual head model: IPS CaseDesigner® and OrthoAnalyzer™. The structured light scanner was used as a gold standard and was superimposed on the virtual head models, created by IPS CaseDesigner® and OrthoAnalyzer™, using an Iterative Closest Point algorithm. Differences between the positions of the intra-oral scans obtained with the software packages were recorded and expressed in six degrees of freedom as well as the inter- and intra-observer intra-class correlation coefficient.
Results
The tested software packages, IPS CaseDesigner® and OrthoAnalyzer™, showed a high level of accuracy compared to the gold standard. The accuracy was calculated for all six degrees of freedom. It was noticeable that the accuracy in the cranial/caudal direction was the lowest for IPS CaseDesigner® and OrthoAnalyzer™ in both the maxilla and mandible. The inter- and intra-observer intra-class correlation coefficient showed a high level of agreement between the observers.
Clinical relevance
IPS CaseDesigner® and OrthoAnalyzer™ are reliable software packages providing an accurate fusion of the intra-oral scan in the CBCT. Both software packages can be used as an accurate fusion tool of the intra-oral scan in the CBCT which provides an accurate basis for 3D virtual planning.
In intra-operative navigation, a registration procedure is performed to register the patient's position to the pre-operative imaging data. The registration process is the main factor that determines ...accuracy of the navigation feedback. In this study, a novel registration protocol for craniofacial surgery is presented, that utilizes a virtual splint with marker points. The accuracy of the proposed method was evaluated by two observers in five human cadaver heads, for optical and electromagnetic navigation, and compared to maxillary bone-anchored fiducial registration (optical and electromagnetic) and surface-based registration (electromagnetic). The results showed minimal differences in accuracy compared to bone-anchored fiducials at the level of the infra-orbital rim. Both point-based techniques had lower error estimates at the infraorbital rim than surface-based registration, but surface-based registration had the lowest loss of accuracy over target distance. An advantage over existing point-based registration methods (bone-anchored fiducials, existing splint techniques) is that radiological imaging does not need to be repeated, since the need for physical fiducials to be present in the image volume is eradicated. Other advantages include reduction of invasiveness compared to bone-achnored fiducials and a possible reduction of human error in the registration process.
The aim of this study was to assess whether the use of intraoral scans (IOS) is an eligible alternative to conventional plaster casts in terms of surgical accuracy of three-dimensionally planned ...bimaxillary osteotomies. This retrospective cohort study included patients who underwent bimaxillary surgery between 2016 and 2020 in the Department of Oral and Maxillofacial Surgery at Radboud University Medical Center, Nijmegen. Three-dimensional virtual planning was performed with the use of plaster casts in one group and IOS in the other group. Cone beam computed tomography scans were acquired preoperatively and at 1 week following surgery. By using voxel-based matching, the maxillary movements were quantified in six degrees of freedom. The primary outcome variable, surgical accuracy, was defined as the difference between the planned maxillary movements and those achieved. Of 152 patients, 113 were documented with plaster casts and 39 with IOS. The surgical accuracy was comparable in terms of maxillary vertical, sagittal, and transverse translations, as well as roll and yaw. Maxillary pitch (difference 0.55 ± 0.26°; P = 0.001) was in favour of the IOS group. This study demonstrated that IOS can be used as an alternative to conventional plaster casts in the three-dimensional planning of bimaxillary osteotomies.
The accuracy of orthognathic surgery has improved with three-dimensional virtual planning. The translation of the planning to the surgical result is reported to vary by >2mm. The aim of this ...randomized controlled multi-centre trial was to determine whether the use of splintless patient-specific osteosynthesis can improve the accuracy of maxillary translation. Patients requiring a Le Fort I osteotomy were included in the trial. The intervention group was treated using patient-specific osteosynthesis and the control group with conventional osteosynthesis and splint-based positioning. Fifty-eight patients completed the study protocol, 27 in the patient-specific osteosynthesis group and 31 in the control group. The per protocol median anteroposterior deviation was found to be 1.05mm (interquartile range (IQR) 0.45–2.72mm) in the patient-specific osteosynthesis group and 1.74mm (IQR 1.02–3.02mm) in the control group. The cranial–caudal deviation was 0.87mm (IQR 0.49–1.44mm) and 0.98mm (IQR 0.28–2.10mm), respectively, whereas the left–right translation deviation was 0.46mm (IQR 0.19–0.96mm) in the patient-specific osteosynthesis group and 1.07mm (IQR 0.62–1.55mm) in the control group. The splintless patient-specific osteosynthesis method improves the accuracy of maxillary translations in orthognathic surgery and is clinically relevant for planned anteroposterior translations of more than 3.70mm.
Virtual occlusion in orthognathic surgery Baan, F.; van Meggelen, E.M.; Verhulst, A.C. ...
International journal of oral and maxillofacial surgery,
09/2021, Letnik:
50, Številka:
9
Journal Article
Recenzirano
Odprti dostop
The aim of this retrospective study was to determine whether a virtually created occlusion is as accurate as a conventionally created occlusion. Seventeen orthognathic patients were included in the ...study, which was conducted in a university clinic. Plaster cast models were obtained and digitized. Two experienced observers created the conventional (gold standard) and virtual occlusion to assess inter-observer variability. One observer created the conventional and virtual occlusion a second time to assess the intra-observer variability. The criterion for accepting the virtual occlusion was that the difference between the gold standard and the virtual occlusion was not larger than the intra-observer variability for the gold standard. A non-parametric Kruskal–Wallis H test was performed to detect statistically significant differences between the intra- and inter-observer groups for both the conventional and virtual occlusion. No statistically significant differences were found between the different groups. The difference between the conventional and virtual occlusion group was 0.20mm larger than the intra-observer variability of the gold standard. The virtual occlusion tool presented here can be utilized in daily clinical practice and makes the use of physical dental models redundant.
Digital surface scanning in flap perfusion Deferm, J.T.; Baan, F.; Schreurs, R. ...
International journal of oral and maxillofacial surgery,
January 2021, 2021-Jan, 2021-01-00, 20210101, Letnik:
50, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Monitoring vascular perfusion of transferred tissue is essential in reconstructive surgery to recognize early flap failure. The aim of this study was to evaluate the ability of a digital surface ...scanner to detect vascular perfusion disorders through the monitoring of skin colour changes. A total of 160 surface scans of the forearm skin were performed with a TRIOS 3D scanner. Vascular compromise was simulated at different time-points by intermittent occlusion of the blood supply to the forearm skin (first the arterial blood supply and then the venous blood supply). Skin colour changes were examined according to the hue, saturation, and value colour scale. Colour differences were analysed with a paired t-test. Significant differences were observed between the colour of the normal skin and that of the vascular compromised skin (P<0.01). The surface scanner could distinguish between arterial occlusion and venous congestion (P<0.01). A digital surface scan is an objective, non-invasive tool to detect early vascular perfusion disorders of the skin.
Objectives
The purpose of this study was to evaluate the clinical accuracy of virtual orthodontic setups by using a new CBCT-based approach.
Materials and methods
Ten patients who underwent ...pre-surgical orthodontics were included in this study. Pre-treatment and pre-surgical cone-beam CT (CBCT) scans and digital dental models were available. The pre-treatment digital dental model was used to create an orthodontic virtual setup. The digital dental models were fused with the corresponding CBCT scans, and the two CBCT scans were aligned using voxel-based matching. Moving each individual tooth from the virtual setup to the final outcome allows the calculation of the accuracy of the virtual setup by using an iterative closest point algorithm. Differences between virtual setup and final outcome were recorded as well as the ICC between two observers.
Results
The inter-observer variability showed a high level of agreement between the observers. The largest mean difference between observers was found in the cranial/caudal direction (0.36 ± 0.30 mm) and the roll rotation (1.54 ± 0.98°). Differences between the virtual setup and final outcome were small in the translational direction (0.45 ± 0.48 mm). Rotational mean differences were larger with the pitch of the incisors (0.00 ± 7.97°) and molars (0.01 ± 10.26°) as largest difference. Excessive extrusion of all upper teeth and more anterior movement than planned were seen for both upper and lower arch. Lower molars showed less extrusion.
Clinical relevance
The data of this study can be used to obtain more insight in the accuracy and achievability of orthodontic virtual setup. Tooth movement can now be studied in more details which can lead to new insights.