Mastcam-Z is a multispectral, stereoscopic imaging investigation on the Mars 2020 mission’s
Perseverance
rover. Mastcam-Z consists of a pair of focusable, 4:1 zoomable cameras that provide broadband ...red/green/blue and narrowband 400-1000 nm color imaging with fields of view from 25.6° × 19.2° (26 mm focal length at 283 μrad/pixel) to 6.2° × 4.6° (110 mm focal length at 67.4 μrad/pixel). The cameras can resolve (≥ 5 pixels) ∼0.7 mm features at 2 m and ∼3.3 cm features at 100 m distance. Mastcam-Z shares significant heritage with the Mastcam instruments on the Mars Science Laboratory
Curiosity
rover. Each Mastcam-Z camera consists of zoom, focus, and filter wheel mechanisms and a 1648 × 1214 pixel charge-coupled device detector and electronics. The two Mastcam-Z cameras are mounted with a 24.4 cm stereo baseline and 2.3° total toe-in on a camera plate ∼2 m above the surface on the rover’s Remote Sensing Mast, which provides azimuth and elevation actuation. A separate digital electronics assembly inside the rover provides power, data processing and storage, and the interface to the rover computer. Primary and secondary Mastcam-Z calibration targets mounted on the rover top deck enable tactical reflectance calibration. Mastcam-Z multispectral, stereo, and panoramic images will be used to provide detailed morphology, topography, and geologic context along the rover’s traverse; constrain mineralogic, photometric, and physical properties of surface materials; monitor and characterize atmospheric and astronomical phenomena; and document the rover’s sample extraction and caching locations. Mastcam-Z images will also provide key engineering information to support sample selection and other rover driving and tool/instrument operations decisions.
•Resting theta connectivity is higher in responders to rTMS for depression.•Combined EEG and mood measures provide 86% response prediction accuracy to rTMS for depression.•Cordance and peak alpha ...frequency showed no differences between responders and non-responders.
Non-response to repetitive transcranial magnetic stimulation (rTMS) treatment for depression is costly for both patients and clinics. Simple and cheap methods to predict response would reduce this burden. Resting EEG measures differentiate responders from non-responders, so may have utility for response prediction.
Fifty patients with treatment resistant depression and 21 controls had resting electroencephalography (EEG) recorded at baseline (BL). Patients underwent 5–8 weeks of rTMS treatment, with EEG recordings repeated at week 1 (W1). Forty-two participants had valid BL and W1 EEG data, and 12 were responders. Responders and non-responders were compared at BL and W1 in measures of theta (4–8 Hz) and alpha (8–13 Hz) power and connectivity, frontal theta cordance and alpha peak frequency. Control group comparisons were made for measures that differed between responders and non-responders. A machine learning algorithm assessed the potential to differentiate responders from non-responders using EEG measures in combination with change in depression scores from BL to W1.
Responders showed elevated theta connectivity across BL and W1. No other EEG measures differed between groups. Responders could be distinguished from non-responders with a mean sensitivity of 0.84 (p = 0.001) and specificity of 0.89 (p = 0.002) using cross-validated machine learning classification on the combination of all EEG and mood measures.
The low response rate limited our sample size to only 12 responders.
Resting theta connectivity at BL and W1 differ between responders and non-responders, and show potential for predicting response to rTMS treatment for depression.
Repetitive transcranial magnetic stimulation (rTMS) is an effective treatment for depression, but only some individuals respond. Predicting response could reduce patient and clinical burden. Neural ...activity related to working memory (WM) has been related to mood improvements, so may represent a biomarker for response prediction.
We expected higher theta and alpha activity in responders compared to non-responders to rTMS.
Fifty patients with treatment resistant depression and twenty controls performed a WM task while electroencephalography (EEG) was recorded. Patients underwent 5–8 weeks of rTMS treatment, repeating the EEG at week 1 (W1). Of the 39 participants with valid WM-related EEG data from baseline and W1, 10 were responders. Comparisons between responders and non-responders were made at baseline and W1 for measures of theta (4–8 Hz), upper alpha (10–12.5 Hz), and gamma (30–45 Hz) power, connectivity, and theta-gamma coupling. The control group's measures were compared to the depression group's baseline measures separately.
Responders showed higher levels of WM-related fronto-midline theta power and theta connectivity compared to non-responders at baseline and W1. Responder's fronto-midline theta power and connectivity was similar to controls. Responders also showed an increase in gamma connectivity from baseline to W1, with a concurrent improvement in mood and WM reaction times. An unbiased combination of all measures provided mean sensitivity of 0.90 at predicting responders and specificity of 0.92 in a predictive machine learning algorithm.
Baseline and W1 fronto-midline theta power and theta connectivity show good potential for predicting response to rTMS treatment for depression.
•Theta power and connectivity are higher in responders to rTMS for depression.•Responders showed working memory and mood improvements after 1 week of treatment.•Combined EEG, behaviour and mood measures provided 91% response prediction accuracy.•Responders show early increases in gamma connectivity compared to non-responders.
Although several studies have reported that repetitive transcranial magnetic stimulation (rTMS) treatment has demonstrable efficacy in patients with depression, the parameters needed to optimize ...therapeutic efficacy remain unclear. To this end we determined the efficacy of low-frequency right rTMS to the dorsolateral prefrontal cortex (DLPFC) compared to two forms of bilateral rTMS to the DLPFC: (1) sequential low-frequency right-sided followed by high-frequency left-sided rTMS and (2) sequential low-frequency rTMS to both hemispheres.
A total of 219 patients with treatment-resistant depression (TRD) were randomized to a 4-week course of rTMS applied with one of the three treatment conditions. Outcomes were assessed with standard rating scales.
Overall, slightly more than 50% of the patients achieved clinical response criteria. There was no substantial difference in response between the unilateral and bilateral treatment groups. Successful response to rTMS was predicted by a greater degree of baseline depression severity.
There is no substantial difference in efficacy between unilateral right-sided rTMS and the two forms of bilateral rTMS assessed in the study. Furthermore, our results call into question the specificity between frequency and laterality and rTMS response.
The Mastcam-Z Camera is a stereoscopic, multispectral camera with zoom capability on NASA’s Mars-2020
Perseverance
rover. The Mastcam-Z relies on a set of two deck-mounted radiometric calibration ...targets to validate camera performance and to provide an instantaneous estimate of local irradiance and allow conversion of image data to units of reflectance (R
∗
or I/F) on a tactical timescale. Here, we describe the heritage, design, and optical characterization of these targets and discuss their use during rover operations. The Mastcam-Z primary calibration target inherits features of camera calibration targets on the Mars Exploration Rovers, Phoenix and Mars Science Laboratory missions. This target will be regularly imaged during flight to accompany multispectral observations of the martian surface. The primary target consists of a gold-plated aluminum base, eight strong hollow-cylinder Sm
2
Co
17
alloy permanent magnets mounted in the base, eight ceramic color and grayscale patches mounted over the magnets, four concentric, ceramic grayscale rings and a central aluminum shadow post (gnomon) painted with an IR-black paint. The magnets are expected to keep the central area of each patch relatively free of Martian aeolian dust. The Mastcam-Z secondary calibration target is a simple angled aluminum shelf carrying seven vertically mounted ceramic color and grayscale chips and seven identical, but horizontally mounted ceramic chips. The secondary target is intended to augment and validate the calibration-related information derived from the primary target. The Mastcam-Z radiometric calibration targets are critically important to achieving Mastcam-Z science objectives for spectroscopy and photometric properties.
Acute calculus cholecystitis is a very common disease with several area of uncertainty. The World Society of Emergency Surgery developed extensive guidelines in order to cover grey areas. The ...diagnostic criteria, the antimicrobial therapy, the evaluation of associated common bile duct stones, the identification of "high risk" patients, the surgical timing, the type of surgery, and the alternatives to surgery are discussed. Moreover the algorithm is proposed: as soon as diagnosis is made and after the evaluation of choledocholitiasis risk, laparoscopic cholecystectomy should be offered to all patients exception of those with high risk of morbidity or mortality. These Guidelines must be considered as an adjunctive tool for decision but they are not substitute of the clinical judgement for the individual patient.
This article documents the muon reconstruction and identification efficiency obtained by the ATLAS experiment for 139
fb
-
1
of
pp
collision data at
s
=
13
TeV collected between 2015 and 2018 during ...Run 2 of the LHC. The increased instantaneous luminosity delivered by the LHC over this period required a reoptimisation of the criteria for the identification of prompt muons. Improved and newly developed algorithms were deployed to preserve high muon identification efficiency with a low misidentification rate and good momentum resolution. The availability of large samples of
Z
→
μ
μ
and
J
/
ψ
→
μ
μ
decays, and the minimisation of systematic uncertainties, allows the efficiencies of criteria for muon identification, primary vertex association, and isolation to be measured with an accuracy at the per-mille level in the bulk of the phase space, and up to the percent level in complex kinematic configurations. Excellent performance is achieved over a range of transverse momenta from 3 GeV to several hundred GeV, and across the full muon detector acceptance of
|
η
|
<
2.7
.
Jet energy scale and resolution measurements with their associated uncertainties are reported for jets using 36–81 fb
-
1
of proton–proton collision data with a centre-of-mass energy of
s
=
13
TeV
...collected by the ATLAS detector at the LHC. Jets are reconstructed using two different input types: topo-clusters formed from energy deposits in calorimeter cells, as well as an algorithmic combination of charged-particle tracks with those topo-clusters, referred to as the ATLAS particle-flow reconstruction method. The anti-
k
t
jet algorithm with radius parameter
R
=
0.4
is the primary jet definition used for both jet types. This result presents new jet energy scale and resolution measurements in the high pile-up conditions of late LHC Run 2 as well as a full calibration of particle-flow jets in ATLAS. Jets are initially calibrated using a sequence of simulation-based corrections. Next, several in situ techniques are employed to correct for differences between data and simulation and to measure the resolution of jets. The systematic uncertainties in the jet energy scale for central jets (
|
η
|
<
1.2
) vary from 1% for a wide range of high-
p
T
jets (
250
<
p
T
<
2000
GeV
), to 5% at very low
p
T
(
20
GeV
) and 3.5% at very high
p
T
(
>
2.5
TeV
). The relative jet energy resolution is measured and ranges from (
24
±
1.5
)% at 20
GeV
to (
6
±
0.5
)% at 300
GeV
.