Public access defibrillation programs can improve survival after out-of-hospital cardiac arrest, but automated external defibrillators (AEDs) are rarely available for bystander use at the scene. ...Drones are an emerging technology that can deliver an AED to the scene of an out-of-hospital cardiac arrest for bystander use. We hypothesize that a drone network designed with the aid of a mathematical model combining both optimization and queuing can reduce the time to AED arrival.
We applied our model to 53 702 out-of-hospital cardiac arrests that occurred in the 8 regions of the Toronto Regional RescuNET between January 1, 2006, and December 31, 2014. Our primary analysis quantified the drone network size required to deliver an AED 1, 2, or 3 minutes faster than historical median 911 response times for each region independently. A secondary analysis quantified the reduction in drone resources required if RescuNET was treated as a large coordinated region.
The region-specific analysis determined that 81 bases and 100 drones would be required to deliver an AED ahead of median 911 response times by 3 minutes. In the most urban region, the 90th percentile of the AED arrival time was reduced by 6 minutes and 43 seconds relative to historical 911 response times in the region. In the most rural region, the 90th percentile was reduced by 10 minutes and 34 seconds. A single coordinated drone network across all regions required 39.5% fewer bases and 30.0% fewer drones to achieve similar AED delivery times.
An optimized drone network designed with the aid of a novel mathematical model can substantially reduce the AED delivery time to an out-of-hospital cardiac arrest event.
Background
Mechanical chest compression devices have been proposed to improve the effectiveness of cardiopulmonary resuscitation (CPR).
Objectives
To assess the effectiveness of resuscitation ...strategies using mechanical chest compressions versus resuscitation strategies using standard manual chest compressions with respect to neurologically intact survival in patients who suffer cardiac arrest.
Search methods
On 19 August 2017 we searched the Cochrane Central Register of Controlled Studies (CENTRAL), MEDLINE, Embase, Science Citation Index‐Expanded (SCI‐EXPANDED) and Conference Proceedings Citation Index–Science databases. Biotechnology and Bioengineering s and Science Citation s had been searched up to November 2009 for prior versions of this review. We also searched two clinical trials registries for any ongoing trials not captured by our search of databases containing published works: Clinicaltrials.gov (August 2017) and the World Health Organization International Clinical Trials Registry Platform portal (January 2018). We applied no language restrictions. We contacted experts in the field of mechanical chest compression devices and manufacturers.
Selection criteria
We included randomised controlled trials (RCTs), cluster‐RCTs and quasi‐randomised studies comparing mechanical chest compressions versus manual chest compressions during CPR for patients with cardiac arrest.
Data collection and analysis
We used standard methodological procedures expected by Cochrane.
Main results
We included five new studies in this update. In total, we included 11 trials in the review, including data from 12,944 adult participants, who suffered either out‐of‐hospital cardiac arrest (OHCA) or in‐hospital cardiac arrest (IHCA). We excluded studies explicitly including patients with cardiac arrest caused by trauma, drowning, hypothermia and toxic substances. These conditions are routinely excluded from cardiac arrest intervention studies because they have a different underlying pathophysiology, require a variety of interventions specific to the underlying condition and are known to have a prognosis different from that of cardiac arrest with no obvious cause. The exclusions were meant to reduce heterogeneity in the population while maintaining generalisability to most patients with sudden cardiac death.
The overall quality of evidence for the outcomes of included studies was moderate to low due to considerable risk of bias. Three studies (N = 7587) reported on the designated primary outcome of survival to hospital discharge with good neurologic function (defined as a Cerebral Performance Category (CPC) score of one or two), which had moderate quality evidence. One study showed no difference with mechanical chest compressions (risk ratio (RR) 1.07, 95% confidence interval (CI) 0.82 to 1.39), one study demonstrated equivalence (RR 0.79, 95% CI 0.60 to 1.04), and one study demonstrated reduced survival (RR 0.41, CI 0.21 to 0.79). Two other secondary outcomes, survival to hospital admission (N = 7224) and survival to hospital discharge (N = 8067), also had moderate quality level of evidence. No studies reported a difference in survival to hospital admission. For survival to hospital discharge, two studies showed benefit, four studies showed no difference, and one study showed harm associated with mechanical compressions. No studies demonstrated a difference in adverse events or injury patterns between comparison groups but the quality of data was low. Marked clinical and statistical heterogeneity between studies precluded any pooled estimates of effect.
Authors' conclusions
The evidence does not suggest that CPR protocols involving mechanical chest compression devices are superior to conventional therapy involving manual chest compressions only. We conclude on the balance of evidence that mechanical chest compression devices used by trained individuals are a reasonable alternative to manual chest compressions in settings where consistent, high‐quality manual chest compressions are not possible or dangerous for the provider (eg, limited rescuers available, prolonged CPR, during hypothermic cardiac arrest, in a moving ambulance, in the angiography suite, during preparation for extracorporeal CPR ECPR, etc.). Systems choosing to incorporate mechanical chest compression devices should be closely monitored because some data identified in this review suggested harm. Special attention should be paid to minimising time without compressions and delays to defibrillation during device deployment.
Previous fMRI studies show that women with eating disorders (ED) have differential neural activation to viewing food images. However, despite clinical differences in their responses to food, ...differential neural activation to thinking about eating food, between women with anorexia nervosa (AN) and bulimia nervosa (BN) is not known.
We compare 50 women (8 with BN, 18 with AN and 24 age-matched healthy controls HC) while they view food images during functional Magnetic Resonance Imaging (fMRI).
In response to food (vs non-food) images, women with BN showed greater neural activation in the visual cortex, right dorsolateral prefrontal cortex, right insular cortex and precentral gyrus, women with AN showed greater activation in the right dorsolateral prefrontal cortex, cerebellum and right precuneus. HC women activated the cerebellum, right insular cortex, right medial temporal lobe and left caudate. Direct comparisons revealed that compared to HC, the BN group showed relative deactivation in the bilateral superior temporal gyrus/insula, and visual cortex, and compared to AN had relative deactivation in the parietal lobe and dorsal posterior cingulate cortex, but greater activation in the caudate, superior temporal gyrus, right insula and supplementary motor area.
Women with AN and BN activate top-down cognitive control in response to food images, yet women with BN have increased activation in reward and somatosensory regions, which might impinge on cognitive control over food consumption and binge eating.
Out-of-hospital cardiac arrest (OHCA) constitutes a significant global health burden, with a survival rate of only 10–12%. Mobile phone technologies have been developed that crowdsource citizen ...volunteers to nearby OHCAs in order to initiate resuscitation prior to ambulance arrival. We performed a scoping review to map the available literature on these crowdsourcing technologies and compared their technical specifications.
A search strategy was developed for five online databases. Two reviewers independently assessed all articles for inclusion and extracted relevant study information. Subsequently, we performed a supplementary internet search and consulted experts to identify all available bystander alert technologies and their specifications.
We included 65 articles examining bystander alerting technologies from more than 15 countries. We also identified 25 unique technologies, of which 18 were described in the included literature. Technologies were text message-based systems (n = 3) or mobile phone applications (n = 22). Most (21/25) used global positioning systems to direct bystanders to victims and nearby AEDs. Response radii for alerts varied widely from 200 m to 10 km. Some technologies incorporated advanced features such as video-conferencing with ambulance dispatch and detailed alert settings. Not all systems required volunteers to have training in cardiopulmonary resuscitation. Only ten studies assessed impact on clinical outcomes. Key barriers discussed included false positive alerts, legal liability, and potential psychological impact on volunteers.
Our review provides a comprehensive overview of crowdsourcing technologies for bystander intervention in out-of-hospital cardiac arrest. Future work should focus on clinical outcomes and methods of addressing barriers to implementation.
To evaluate the association between bystander cardiopulmonary resuscitation (CPR), automated external defibrillator (AED) use, and survival after out-of-hospital cardiac arrest (OHCA) across the ...urban–rural spectrum.
This was a retrospective cohort study of 325,477 adult OHCAs within the Cardiac Arrest Registry to Enhance Survival from 2013 to 2019. Bystander interventions were categorized into no bystander intervention, bystander CPR alone, and bystander AED use (with or without CPR). The primary outcome was survival to hospital discharge with good neurological outcome. Multivariable logistic regression was used to evaluate the association between bystander interventions and survival by geographical status (urban, suburban, large rural, small town, or rural).
Bystander CPR alone occurred most often in rural areas (50.8%), and least often in urban areas (35.4%). Bystander AED use in public settings was similar across the urban–rural spectrum (10.5–13.1%). Survival with good neurological outcome varied for urban (8.1%), suburban (7.7%), large rural (9.1%), small town (7.1%), and rural areas (6.1%). In comparison to no bystander intervention, the adjusted odds ratios (95% confidence intervals) for bystander AED use and survival were 2.57 (2.37–2.79) in urban areas, 2.58 (1.81–3.67) in suburban areas, 1.99 (1.44–2.76) in large rural areas, 1.90 (1.27–2.86) in small towns, and 3.05 (1.99–4.68) in rural areas. Bystander CPR alone was also associated with survival in all areas (adjusted odds ratio range: 1.29–1.45). There was no strong evidence of interaction between bystander interventions and geographical status on the primary outcome (p = 0.63).
Bystander CPR and AED use are associated with positive clinical outcomes after OHCA in all areas along the urban–rural spectrum.
Guidelines for cardiopulmonary resuscitation recommend a chest compression rate of at least 100 compressions/min. A recent clinical study reported optimal return of spontaneous circulation with rates ...between 100 and 120/min during cardiopulmonary resuscitation for out-of-hospital cardiac arrest. However, the relationship between compression rate and survival is still undetermined.
Prospective, observational study.
Data is from the Resuscitation Outcomes Consortium Prehospital Resuscitation IMpedance threshold device and Early versus Delayed analysis clinical trial.
Adults with out-of-hospital cardiac arrest treated by emergency medical service providers.
None.
Data were abstracted from monitor-defibrillator recordings for the first five minutes of emergency medical service cardiopulmonary resuscitation. Multiple logistic regression assessed odds ratio for survival by compression rate categories (<80, 80-99, 100-119, 120-139, ≥140), both unadjusted and adjusted for sex, age, witnessed status, attempted bystander cardiopulmonary resuscitation, location of arrest, chest compression fraction and depth, first rhythm, and study site. Compression rate data were available for 10,371 patients; 6,399 also had chest compression fraction and depth data. Age (mean±SD) was 67±16 years. Chest compression rate was 111±19 per minute, compression fraction was 0.70±0.17, and compression depth was 42±12 mm. Circulation was restored in 34%; 9% survived to hospital discharge. After adjustment for covariates without chest compression depth and fraction (n=10,371), a global test found no significant relationship between compression rate and survival (p=0.19). However, after adjustment for covariates including chest compression depth and fraction (n=6,399), the global test found a significant relationship between compression rate and survival (p=0.02), with the reference group (100-119 compressions/min) having the greatest likelihood for survival.
After adjustment for chest compression fraction and depth, compression rates between 100 and 120 per minute were associated with greatest survival to hospital discharge.
Background Time to treatment is critical for survival from sudden cardiac arrest. Every minute delay in defibrillation results in a 7% to 10% reduction in survival. This is particularly problematic ...in rural and remote regions, where emergency medical service response is prolonged and automated external defibrillators (AEDs) are often not available. Our primary objective was to examine the feasibility of a novel AED drone delivery method for rural and remote sudden cardiac arrest. A secondary objective was to compare response times between AED drone delivery and ambulance to mock sudden cardiac arrest resuscitations. Methods and Results We conducted 6 simulations in 2 rural communities in southern Ontario, Canada. In the first 2 simulations, the drone and ambulance were dispatched from the same paramedic base. In simulations 3 and 4, the drone and ambulance were dispatched from separate paramedic bases; and in simulations 5 and 6, the drone was dispatched from an optimized location. During each simulation, a "mock" call was placed to 911 and a single AED drone and an ambulance were simultaneously dispatched to a predetermined destination. On scene, trained first responders retrieved the AED from the drone and initiated resuscitative efforts on a mannequin until paramedics arrived. No difficulties were encountered during drone activation by dispatch, ascent, landing, or bystander retrieval of the AED from the drone. During simulations 1 and 2, the distance to the scene was 6.6 km. For simulations 3 and 4, the ambulance response distance increased to 8.8 km while drone remained at 6.6 km; and in simulations 5 and 6, the ambulance response distance was 20 km compared with 9 km for the drone. During each flight, the AED drone arrived on scene before the ambulance, between 1.8 and 8.0 minutes faster. Conclusions This study suggests AED drone delivery is feasible, with the potential for improvements in response time during simulated sudden cardiac arrest scenarios. Further research is required to determine the appropriate system configuration for AED drone delivery in an integrated emergency medical service system as well as optimal strategies to simplify bystander application of a drone-delivered AED.
Controlling Salmonella in poultry is an ongoing food safety measure and while significant progress has been made, there is a need to continue to evaluate different strategies that include ...understanding Salmonella-poultry interaction, Salmonella-microbiota interactions, Salmonella genetics and response to adverse conditions, and preharvest and postharvest parameters that enable persistence. The purpose of this symposium is to discuss different strategies to consider from feed milling to the farm to the processing environment. This Poultry Science Association symposium paper is divided into 5 different sections that covers 1) immunological aspects of Salmonella control, 2) application of Salmonella genetics for targeted control strategies in poultry production, 3) improving poultry feed hygienics: utilizing feed manufacture techniques and equipment to improve feed hygienics, 4) practical on farm interventions for controlling Salmonella—what works and what may not work, and 5) monitoring and mitigating Salmonella in poultry. These topics elucidate the critical need to establish control strategies that will improve poultry gut health and limit conditions that exposes Salmonella to stress causing alterations to virulence and pathogenicity both at preharvest and postharvest poultry production. This information is relevant to the poultry industry's continued efforts to ensure food safety poultry production.