Objective One of the main problems of lung transplantation is the shortage of organs as well as reduced survival rates. In the absence of an international standardized model for lung donor-recipient ...allocation, we set out to develop such a model based on the characteristics of past experiences with lung donors and recipients with the aim of improving the outcomes of the entire transplantation process. Methods This was a retrospective analysis of 404 lung transplants carried out at the Reina Sofía University Hospital (Córdoba, Spain) over 23 years. We analyzed various clinical variables obtained via our experience of clinical practice in the donation and transplantation process. These were used to create various classification models, including classical statistical methods and also incorporating newer machine-learning approaches. Results The proposed model represents a powerful tool for donor-recipient matching, which in this current work, exceeded the capacity of classical statistical methods. The variables that predicted an increase in the probability of survival were: higher pre-transplant and post-transplant functional vital capacity (FVC), lower pre-transplant carbon dioxide (PCO2) pressure, lower donor mechanical ventilation, and shorter ischemia time. The variables that negatively influenced transplant survival were low forced expiratory volume in the first second (FEV1) pre-transplant, lower arterial oxygen pressure (PaO2)/fraction of inspired oxygen (FiO2) ratio, bilobar transplant, elderly recipient and donor, donor-recipient graft disproportion requiring a surgical reduction (Tailor), type of combined transplant, need for cardiopulmonary bypass during the surgery, death of the donor due to head trauma, hospitalization status before surgery, and female and male recipient donor sex. Conclusions These results show the difficulty of the problem which required the introduction of other variables into the analysis. The combination of classical statistical methods and machine learning can support decision-making about the compatibility between donors and recipients. This helps to facilitate reliable prediction and to optimize the grafts for transplantation, thereby improving the transplanted patient survival rate.
A
bstract
The NEXT experiment aims to observe the neutrinoless double beta decay of
136
Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. One ...of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to
Q
ββ
. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype.
Single electrons resulting from the interactions of
22
Na 1275 keV gammas and electronpositron pairs produced by conversions of gammas from the
228
Th decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24
.
3 ± 1
.
4 (stat.)%, while maintaining an efficiency of 66
.
7 ± 1
.
% for signal events.
Xe–CO2 mixtures are important alternatives to pure xenon in Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification with applications in the ...important field of rare event detection such as directional dark matter, double electron capture and double beta decay detection. The addition of CO2 to pure xenon at the level of 0.05–0.1% can reduce significantly the scale of electron diffusion from 10 mm/m to 2.5 mm/m, with high impact on the discrimination efficiency of the events through pattern recognition of the topology of primary ionization trails. We have measured the electroluminescence (EL) yield of Xe–CO2 mixtures, with sub-percent CO2 concentrations. We demonstrate that the EL production is still high in these mixtures, 70% and 35% relative to that produced in pure xenon, for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of the statistical fluctuations in EL production to the energy resolution increases with increasing CO2 concentration, being smaller than the contribution of the Fano factor for concentrations below 0.1% CO2.
NEXT: Neutrino Experiment with high pressure Xenon gas TPC Yahlali, Nadia; Ball, M.; Cárcel, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
05/2010, Letnik:
617, Številka:
1
Journal Article
Recenzirano
The search of the neutrinoless double-
β
decay address the major Physics goals of revealing the nature of the neutrino and setting an absolute scale for its mass. The observation of a positive
β
β
0
...ν
signal, the unique signature of Majorana neutrinos, would have deep consequences in particle physics and cosmology. Therefore, any claim of observing a positive signal shall require extremely robust evidences. NEXT is a new double-
β
experiment which aims at building a 100
kg high pressure
Xe
136
gas TPC, to be hosted in the Canfranc Underground Laboratory (LSC), in Spain. This paper address the novel design concept of NEXT TPC believed to provide a pathway for an optimized and robust double-
β
experiment.
We report a measurement of the half-life of the 136Xe two-neutrino double-β decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the ...NEXT-White detector operated with 136Xe-enriched and 136Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34$_{-0.46}^{+0.80}$(stat)$_{-0.17}^{+0.30}$(sys)×1021yr is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-β-decay searches.
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (EL TPC) by reducing ...the diffusion of the drifting electrons while keeping nearly intact the energy resolution of a pure xenon EL TPC. Based on state-of-the-art microscopic simulations, a substantial addition of helium, around 10 or 15 %, may reduce drastically the transverse diffusion down to 2.5 mm/m from the 10.5 mm/m of pure xenon. The longitudinal diffusion remains around 4 mm/m. Light production studies have been performed as well. They show that the relative variation in energy resolution introduced by such a change does not exceed a few percent, which leaves the energy resolution practically unchanged. The technical caveats of using photomultipliers close to an helium atmosphere are also discussed in detail.
We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White time projection chamber (TPC) and a dedicated setup. Detailed comparison with ...first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that is postulated to exist in xenon that has been largely overlooked. For photon emission below 1000 nm, the NBrS yield increases from about10−2photon/e−cm−1bar−1at pressure-reduced electric field values of50Vcm−1bar−1to above3×10−1photon/e−cm−1bar−1at500Vcm−1bar−1. Above1.5kVcm−1bar−1, values that are typically employed for electroluminescence, it is estimated that NBrS is present with an intensity around1photon/e−cm−1bar−1, which is about 2 orders of magnitude lower than conventional, excimer-based electroluminescence. Despite being fainter than its excimeric counterpart, our calculations reveal that NBrS causes luminous backgrounds that can interfere, in either gas or liquid phase, with the ability to distinguish and/or to precisely measure low primary-scintillation signals (S1). In particular, we show this to be the case in the “buffer” region, where keeping the electric field below the electroluminescence threshold does not suffice to extinguish secondary scintillation. The electric field leakage in this region should be mitigated to avoid intolerable levels of NBrS emission. Furthermore, we show that this new source of light emission opens up a viable path toward obtaining S2 signals for discrimination purposes in future single-phase liquid TPCs for neutrino and dark matter physics, with estimated yields up to20–50photons/e−cm−1.