Since echinocandins are recommended as first line therapy for invasive candidiasis, detection of resistance, mainly due to alteration in FKS protein, is of main interest. EUCAST AFST recommends ...testing both MIC of anidulafungin and micafungin, and breakpoints (BPs) have been proposed to detect echinocandin-resistant isolates. We analyzed MIC distribution for all three available echinocandins of 2,787 clinical yeast isolates corresponding to 5 common and 16 rare yeast species, using the standardized EUCAST method for anidulafungin and modified for caspofungin and micafungin (AM3-MIC). In our database, 64 isolates of common pathogenic species were resistant to anidulafungin, according to the EUCAST BP, and/or to caspofungin, using our previously published threshold (AM3-MIC ≥ 0.5 mg/L). Among these 64 isolates, 50 exhibited 21 different FKS mutations. We analyzed the capacity of caspofungin AM3-MIC and anidulafungin MIC determination in detecting isolates with FKS mutation. They were always identified using caspofungin AM3-MIC and the local threshold while some isolates were misclassified using anidulafungin MIC and EUCAST threshold. However, both methods misclassified four wild-type C. glabrata as resistant. Based on a large data set from a single center, the use of AM3-MIC testing for caspofungin looks promising in identifying non-wild-type C. albicans, C. tropicalis and P. kudiravzevii isolates, but additional multicenter comparison is mandatory to conclude on the possible superiority of AM3-MIC testing compared to the EUCAST method.
In spite of the immense potential of biodegradable magnesium alloys, the fast degradation rates of Mg-based biomedical implants in the physiological environment impose severe limitations in many ...clinical applications. Consequently, extensive in vitro studies have been carried out to investigate the materials’ performance and fathom the associated mechanisms. Here, an up-to-date review of the in vitro studies on biomedical magnesium alloys in a simulated physiological environment is provided. This review focuses on four topics: (1) materials selection and in vitro biocompatibility of biomedical magnesium alloys; (2) in vitro degradation of biomedical magnesium alloys in simulated physiological environments, specifically discussing corrosion types, degradation rates, corrosion products and impact of the constituents in body fluids on materials degradation; (3) selection of suitable test media for in vitro assessment; and (4) future research trends.
We propose an experimental search for an axion-induced oscillating electric dipole moment (OEDM) for electrons using state-of-the-art alkali vapor-cell atomic magnetometers. The axion is a ...hypothesized new fundamental particle which can resolve the strong charge-parity problem and be a prominent dark matter candidate. This experiment utilizes an atomic magnetometer as both a source of optically polarized electron spins and a magnetic-field sensor. The interaction of the axion field, oscillating at a frequency equal to the axion mass, with an electron spin induces a sizable OEDM of the electron at the same frequency as the axion field. When the alkali vapor is subjected to an electric field and a magnetic field, the electron OEDM interacts with the electric field, resulting in an electron spin precession at the spin's Larmor frequency in the magnetic field. The resulting precession signal can be sensitively detected with a probe laser beam of the atomic magnetometer. We estimate that the experiment is sensitive to the axion-photon interaction in ultralight axion masses from 10−15 to 10−10 eV. It is able to improve the current experimental limit up to 5 orders of magnitude, exploring new axion parameter spaces.
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We ...have characterized a PPC detector’s response to
α
particles incident on the sensitive passivated and p
+
surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the
Majorana
Demonstrator
experiment, a search for neutrinoless double-beta decay (
0
ν
β
β
) in
76
Ge.
α
decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of
α
identification, reliably identifying
α
background events on the passivated surface of the detector. We demonstrate effective rejection of all surface
α
events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the
0
ν
β
β
region of interest window by an order of magnitude in the
Majorana
Demonstrator
and will be used in the upcoming LEGEND-200 experiment.
Plasma-surface modification (PSM) is an effective and economical surface treatment technique for many materials and of growing interests in biomedical engineering. This article reviews the various ...common plasma techniques and experimental methods as applied to biomedical materials research, such as plasma sputtering and etching, plasma implantation, plasma deposition, plasma polymerization, laser plasma deposition, plasma spraying, and so on. The unique advantage of plasma modification is that the surface properties and biocompatibility can be enhanced selectively while the bulk attributes of the materials remain unchanged. Existing materials can, thus, be used and needs for new classes of materials may be obviated thereby shortening the time to develop novel and better biomedical devices. Recent work has spurred a number of very interesting applications in the biomedical field. This review article concentrates upon the current status of these techniques, new applications, and achievements pertaining to biomedical materials research. Examples described include hard tissue replacements, blood contacting prostheses, ophthalmic devices, and other products.
The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in ^{76}Ge) array of p-type, point-contact germanium detectors. With its unprecedented energy ...resolution and ultralow backgrounds, Majorana also searches for rare event signatures from beyond standard model physics in the low energy region below 100 keV. In this Letter, we test the continuous spontaneous localization (CSL) model, one of the mathematically well-motivated wave function collapse models aimed at solving the long-standing unresolved quantum mechanical measurement problem. While the CSL predicts the existence of a detectable radiation signature in the x-ray domain, we find no evidence of such radiation in the 19-100 keV range in a 37.5 kg-y enriched germanium exposure collected between December 31, 2015, and November 27, 2019, with the Demonstrator. We explored both the non-mass-proportional (n-m-p) and the mass-proportional (m-p) versions of the CSL with two different assumptions: that only the quasifree electrons can emit the x-ray radiation and that the nucleus can coherently emit an amplified radiation. In all cases, we set the most stringent upper limit to date for the white CSL model on the collapse rate, λ, providing a factor of 40-100 improvement in sensitivity over comparable searches. Our limit is the most stringent for large parts of the allowed parameter space. If the result is interpreted in terms of the Diòsi-Penrose gravitational wave function collapse model, the lower bound with a 95% confidence level is almost an order of magnitude improvement over the previous best limit.
Among patients with implantable pacemakers and defibrillators, subclinical atrial fibrillation (SCAF) is associated with an increased risk of stroke; however, there is limited understanding of their ...temporal relationship.
The Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial (ASSERT) enrolled 2580 pacemaker and defibrillator patients aged ≥65 years with a history of hypertension but without a history of atrial fibrillation. Pacemakers and implantable cardioverter-defibrillators precisely logged the time and duration of all episodes of SCAF and recorded electrograms that were adjudicated by experts. We examined the temporal relationship between SCAF >6 minutes in duration and stroke or systemic embolism. Of 51 patients who experienced stroke or systemic embolism during follow-up, 26 (51%) had SCAF. In 18 patients (35%), SCAF was detected before stroke or systemic embolism. However, only 4 patients (8%) had SCAF detected within 30 days before stroke or systemic embolism, and only 1 of these 4 patients was experiencing SCAF at the time of the stroke. In the 14 patients with SCAF detected >30 days before stroke or systemic embolism, the most recent episode occurred at a median interval of 339 days (25th to 75th percentile, 211-619) earlier. Eight patients (16%) had SCAF detected only after their stroke, despite continuous monitoring for a median duration of 228 days (25th to 75th percentile, 202-719) before their event.
Although SCAF is associated with an increased risk of stroke and embolism, very few patients had SCAF in the month before their event.
http://www.clinicaltrials.gov. Unique identifier: NCT00256152.
The Majorana Demonstrator is an ultralow-background experiment searching for neutrinoless double-beta decay in ^{76}Ge. The heavily shielded array of germanium detectors, placed nearly a mile ...underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly ionizing particles with an electrical charge less than e are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the Majorana Demonstrator by searching for multiple-detector events with individual-detector energy depositions down to 1 keV. This search is background-free, and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as e/1000.