We report new results from the Cryogenic Dark Matter Search (CDMS II) at the Soudan Underground Laboratory. Two towers, each consisting of six detectors, were operated for 74.5 live days, giving ...spectrum-weighted exposures of 34 (12) kg d for the Ge (Si) targets after cuts, averaged over recoil energies 10-100 keV for a weakly interacting massive particle (WIMP) mass of 60 GeV/c2. A blind analysis was conducted, incorporating improved techniques for rejecting surface events. No WIMP signal exceeding expected backgrounds was observed. When combined with our previous results from Soudan, the 90% C.L. upper limit on the spin-independent WIMP-nucleon cross section is 1.6 x 10(-43) cm2 from Ge and 3 x 10(-42) cm2 from Si, for a WIMP mass of 60 GeV/c2. The combined limit from Ge (Si) is a factor of 2.5 (10) lower than our previous results and constrains predictions of supersymmetric models.
We report the first results from a search for weakly interacting massive particles (WIMPs) in the Cryogenic Dark Matter Search experiment at the Soudan Underground Laboratory. Four Ge and two Si ...detectors were operated for 52.6 live days, providing 19.4 kg d of Ge net exposure after cuts for recoil energies between 10 and 100 keV. A blind analysis was performed using only calibration data to define the energy threshold and selection criteria for nuclear-recoil candidates. Using the standard dark-matter halo and nuclear-physics WIMP model, these data set the world's lowest exclusion limits on the coherent WIMP-nucleon scalar cross section for all WIMP masses above 15 GeV/c2, ruling out a significant range of neutralino supersymmetric models. The minimum of this limit curve at the 90% C.L. is 4 x 10(-43) cm2 at a WIMP mass of 60 GeV/c2.
The Cryogenic Dark Matter Search (CDMS) employs Ge and Si detectors to search for weakly interacting massive particles (WIMPs) via their elastic-scattering interactions with nuclei while ...discriminating against interactions of background particles. CDMS data, accounting for the neutron background, give limits on the spin-independent WIMP-nucleon elastic-scattering cross section that exclude unexplored parameter space above 10 GeV/c2 WIMP mass and, at >75% C.L., the entire 3sigma allowed region for the WIMP signal reported by the DAMA experiment.
Low-threshold analysis of CDMS shallow-site data Akerib, D. S.; Attisha, M. J.; Baudis, L. ...
Physical review. D, Particles, fields, gravitation, and cosmology,
12/2010, Letnik:
82, Številka:
12
Journal Article
The SuperCDMS proposal for dark matter detection Akerib, D.S.; Attisha, M.J.; Bailey, C.N. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2006, Letnik:
559, Številka:
2
Journal Article
Recenzirano
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle (WIMP) search at the Soudan Underground Laboratory sets the most stringent exclusion limits of any WIMP cold dark matter ...direct-detection experiment. To extend our reach further, to WIMP-nucleon cross-sections in the range
10
-
46
-
10
-
44
cm
2
, we propose SuperCDMS, which would take advantage of a very deep site. One promising site is the recently approved SNOLab facility in Canada. In this paper we will present our overall program and focus on phase A of SuperCDMS.
While driving simulators are a valuable tool for assessing multiple dimensions of driving performance under relatively safe conditions, researchers and practitioners must be prepared for participants ...that suffer from simulator sickness. This paper describes multiple theories of motion sickness and presents a method for assessing and reacting to simulator sickness symptoms. Results showed that this method identified individuals who were unable to complete a driving simulator study due to simulator sickness with greater than 90% accuracy and that older participants had a greater likelihood of simulator sickness than younger participants. Possible explanations for increased symptoms experienced by older participants are discussed as well as implications for research ethics and simulator sickness prevention.
Final results are reported from operation of the PICO-60 C3F8 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. The chamber was operated ...at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.2×10−41 cm2 for a 25 GeV WIMP, improving on previous PICO results for 3–5 GeV WIMPs by an order of magnitude.
We present the results of the first two data runs of the Cryogenic Dark Matter Search at Soudan Underground Laboratory. These data exclude substantial new parameter space for both spin-independent ...and spin-dependent WIMP–nucleon interactions within the standard halo model.