Objective The objective of the study was to prospectively evaluate the accuracy of laparoscopy performed in satellite centers (SCs) to describe intraabdominal diffusion of advanced ovarian cancer ...(AOC). Study Design Patients with a clinical/radiological suspicion of AOC were included in the protocol. SCs were selected among those surgeons, spending a short intensive training period at the coordinator center (CC) to learn the application of staging laparoscopy (S-LPS) in AOC. All women underwent S-LPS at the SCs, and the surgical procedure was recorded and blindly reviewed at the CC. Calculating specificity, positive and negative predictive values, and the accuracy for each parameter with respect to the CC assessed the diagnostic performance of S-LPS. The Cohen's kappa was used to test the interobserver agreement of each parameter. Results One hundred sixty-eight cases were considered eligible for the study. A per-protocol analysis was performed on 120 cases. The worst laparoscopic assessable feature was mesenteric retraction, whereas the remaining variables ranged from 99.2% (peritoneal carcinomatosis) to 90% (bowel infiltration). All but 1 SC (SC number 4) reached an accuracy rate of 80% or greater for both single parameters and overall score. The Cohen's kappa and the P value for overall predicitive index value were 0.685 and .01, respectively, but improved to 0.773 and .388 after removing the SC number 4 from the analysis. Conclusion S-LPS allows an accurate and reliable assessment of intraperitoneal diffusion of disease in AOC patients in trained gynecological oncology centers.
Purpose of the article. To explore the strength of association between different maternal and pregnancy characteristics and the occurrence of abnormally invasive placenta (AIP).
Materials and ...methods: Pubmed, Embase, CINAHL databases were searched. The risk factors for AIP explored were: obesity, age >35 years, smoking before or during pregnancy, placenta previa, prior cesarean section (CS), placenta previa and prior CS, prior uterine surgery, abortion and uterine curettage, in vitro fertilization (IVF) pregnancy and interval between a previous CS, and a subsequent pregnancy. Random-effect head-to-head meta-analyses were used to analyze the data.
Results: Forty-six were included in the systematic review. Maternal obesity (Odd ratio, OR: 1.4, 95% CI 1.0-1.8), advanced maternal age (OR: 3.1, 95% CI 1.4-7.0) and parity (OR: 2.5, 95% CI 1.7-3.6), but not smoking were associated with a higher risk of AIP. The presence of placenta previa in women with at least a prior CS was associated with a higher risk of AIP compared to controls, with an OR of 12.0, 95% CI 1.6-88.0. Furthermore, the risk of AIP increased with the number of prior CS (OR of 2.6, 95% CI 1.6-4.4 and 5.4, 95% CI 1.7-17.4 for two and three prior CS respectively). Finally, IVF pregnancies were associated with a high risk of AIP, with an OR of 2.8 (95% CI 1.2-6.8).
Conclusion: A prior CS and placenta previa are among the strongest risk factors for the occurrence of AIP.
Introduction
Our objective was to elucidate the overall diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation (AIP).
Material and methods
Medline, Embase, ...CINAHL and The Cochrane databases were searched. The ultrasound signs explored were: loss of hypoechoic (clear) zone in the placental–uterine interface, placental lacunae, bladder wall interruption, myometrial thinning, focal exophitic mass, placental lacunar flow, subplacental vascularity, and uterovesical hypervascularity.
Results
Twenty studies (3209 pregnancies) were included. Ultrasound had an overall good diagnostic accuracy in identifying the depth of placental invasion with sensitivities of 90.6%, 93.0%, 89.5%, and 81.2% for placenta accreta, increta, accreta/increta, and percreta, respectively; the corresponding specificities were 97.1%, 98.4%, 94.7%, and 98.9%. Placental lacunae had sensitivities of 74.8%, 88.6%, and 76.3% for the detection of placenta accreta, increta, and percreta, respectively. Sensitivity and specificity of loss of the clear zone in identifying placenta accreta were 74.9% and 92.0%, whereas the corresponding figures for placenta increta and percreta were 91.6% and 76.9%, and 88.1% and 71.1%. Lacunar flow had sensitivities of 81.2%, 84.3%, and 45.2% for the detection of placenta accreta, increta, and percreta respectively; the corresponding figures for specificity were 84.0%, 79.7%, and 75.3%. Sensitivity of uterovesical hypervascularity was low for the detection of placenta accreta (12.3%) but high for placenta increta (94.4%) and percreta (86.2%); the corresponding figures for specificity were 90.8%, 88.0% and 88.2%, respectively.
Conclusions
Ultrasound has an overall good diagnostic accuracy in recognizing the depth and the topography of placental invasion.
This study provides a detailed description of the new HUGO™ RAS System and suggests docking settings for gynecological surgery. The system is composed of an “open” surgical console with an HD–3D ...passive display, a system tower, and four arm carts. Each arm has an extremely wide range of adaptability resulting from the numerous joints. The human cadaver labs were performed at the ORSI Academy between August and December 2021. All procedures were performed by two surgical teams, each composed of a high-volume surgeon experienced in robotic surgery, gynecologic oncology, and pelvic sidewall surgery, and one bedside assistant. Three main gynecological surgical scenarios were identified: standard pelvic surgery, pelvic sidewall surgery, and para-aortic/upper abdominal surgery. Concerning the port placement, the chosen options were called “straight” and “bridge”; instead, the so-called “compact” and “butterfly” configurations were identified for the arm cart positioning. Four cadavers were used to perform total hysterectomy, radical hysterectomy, pelvic exenteration, pelvic and para-aortic lymphadenectomy, and omentectomy. We performed several tests, identifying the best system configurations to draw the proper efficiency from the flexibility of the system in all gynecological surgical scenarios. The straight port placement seems to be adequate for standard pelvic surgery. The bridge trocar position is best to reach the deeper and lateral anatomical regions of the female pelvis. The compact and butterfly arm cart allocations are adequate for both straight and bridge port placement. When deep pelvic surgery was performed, the bedside assistant became more proficient by working with a standard laparoscopic instrument from an ancillary port placed in the left iliac fossa. The arm carts needed to be moved in an open manner, like for the proposed butterfly configuration. On the contrary, the compact disposition left enough space to assist from Palmer’s point port. Several basic and advanced gynecological surgical procedures were performed and completed successfully without encountering any technical or surgical issue, the results obtained were judged sufficient to proceed with the clinical experience in daily practice. The HUGO™ RAS system is flexible and highly performative in various surgical scenarios.
Background Although widely adopted, the use of a uterine manipulator during laparoscopic treatment of endometrial cancer represents a debated issue, and some authors hypothesize that it potentially ...may cause an increased risk of relapse, particularly at specific sites. Objective Our aim was to evaluate the risk and site of disease recurrence, overall survival, and disease-specific survival in women who had laparoscopic surgery with and without the use of a uterine manipulator. Study Design Data were reviewed from consecutive patients who had laparoscopic surgery for endometrial cancer staging in 7 Italian centers. Subjects were stratified according to whether a uterine manipulator was used during surgery; if so, the type of manipulator was identified. Multivariable analysis to correct for possible confounders and propensity score that matched the minimize selection bias were utilized. The primary outcome was the risk of disease recurrence. Secondary outcomes were disease-specific and overall survival and the site of recurrence, according to the use or no use of the uterine manipulator and to the different types of manipulators used. Results We included 951 patients: 579 patients in the manipulator group and 372 patients in the no manipulator group. After a median follow-up period of 46 months (range,12–163 months), the rate of recurrence was 13.5% and 11.6% in the manipulator and no manipulator groups, respectively ( P =.37). Positive lymph nodes and myometrial invasion of >50% were associated independently with the risk of recurrence after adjustment for possible confounders. The use of a uterine manipulator did not affect the risk of recurrence, both at univariate (odds ratio, 1.18; 95% confidence interval, 0.80–1.77) and multivariable analysis (odds ratio, 1.00; 95% confidence interval, 0.60–1.70). Disease-free, disease-specific, and overall survivals were similar between groups. Propensity-matched analysis confirmed these findings. The site of recurrence was comparable between groups. In addition, the type of uterine manipulator and the presence or not of a balloon at the tip of the device were not associated significantly with the risk of recurrence. Conclusion The use of a uterine manipulator during laparoscopic surgery does not affect the risk of recurrence and has no impact on disease-specific or overall survival and on the site of recurrence in women affected by endometrial cancer.
Lymph vascular space involvement (LVSI) is one of the most important prognostic factors in early stage cervical cancer. Its qualitative evaluation represents a milestone for patient risk ...stratification and treatment choice, but a semi-quantitative analysis of LVSI may offer a more truthful risk model, as already demonstrated for endometrial cancer. The present study aims to investigate the performances of a semi-quantitative evaluation of LVSI in terms of patient risk assessment.
In this retrospective study were enrolled patients underwent surgical treatment for early cervical cancer from January 2009 to October 2018. A semi-quantitative evaluation such as the “three-tiered approach” was used to classify the LVSI pathway: negative vs. focal vs. diffuse.
Diffuse LVSI was found to be a risk factor for lymph node metastasis (OR: 9.844, p < 0.001), and parametrial involvement (OR: 5.566, p < 0.001). Lymph nodal recurrences were more frequent in diffuse LVSI group (LVSI negative vs. focal LVSI p = 0.369; LVSI negative vs. diffuse LVSI p = 0.002; Focal LVSI vs. diffuse LVSI p = 0.214); and so distant recurrences (LVSI negative vs. focal LVSI p = 0.623; LVSI negative vs. diffuse LVSI p = 0.002; Focal LVSI vs. diffuse LVSI p = 0.026).
Patients with diffuse LVSI showed a worse disease-free survival (DFS) than patients with focal or absent involvement (DFS LVSI negative vs. focal LVSI p = 0.938; LVSI negative vs. diffuse LVSI p < 0.001; focal LVSI vs. diffuse LVSI p = 0.036).
Semi-quantitative evaluation of LVSI may be useful to identify risk patients for shorter disease-free survival and lymphatic and distant recurrences in patients with early stage.
•In Early stage Cervical cancer, diffuse Lymph Vascular Space Involvement (LVSI) are a risk factor for lymph node metastasis.•Patients with diffuse LVSI show a worse disease-free survival (DFS) than patients with focal or absent involvement.•Lymph nodal and distant recurrences are more frequent in patients with diffuse LVSI.
OBJECTIVE: To compare postoperative pain after laparoendoscopic single-site surgery (LESS) approach with conventional multiaccess laparoscopy (LPS). STUDY DESIGN: Prospective randomized trial. ...SETTING: University hospital. PATIENT(S): Benign adnexal disease. INTERVENTION(S): Postoperative pain was measured by using the visual analog scale (VAS) at 20 minutes, 2 hours, 4 hours, and 8 hours after surgery. The need for postoperative rescue doses of analgesia was also recorded. MAIN OUTCOME MEASURE(S): Pain after surgery. RESULT(S): A total of 60 patients were enrolled. Within 8 hours, patients who underwent conventional LPS complained of statistically significant greater postoperative pain at VAS evaluation than those undergoing LESS, both at rest and after Valsalva maneuver, with a higher need for rescue analgesia. CONCLUSION(S): LESS provides an advantage over conventional multiaccess LPS in terms of postoperative pain and need for rescue analgesia, with similar perioperative outcomes.