Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in ...low-risk patients.
We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods.
Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm
vs. 2.0 cm
).
In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).
To evaluate the safety, efficacy, and performance of the TriGuard™ HDH Embolic Deflection Device (TriGuard) compared with no cerebral protection in patients undergoing transcatheter aortic valve ...implantation (TAVI).
From February 2014 to March 2015, 85 subjects undergoing TAVI at 13 centres in Europe and Israel were randomized to TriGuard protection vs. no protection. Subjects underwent neurologic and cognitive evaluation at baseline, pre-discharge and 30 days; cerebral diffusion-weighted magnetic resonance imaging was performed at 4 ± 2 days post-procedure and at 30 days. Technical success, which included complete 3-vessel cerebral coverage, was achieved in 88.9% (40/45) of cases. The primary in-hospital procedural safety endpoint (death, stroke, life-threatening or disabling bleeding, stage 2 or 3 acute kidney injury, or major vascular complications) occurred in 21.7% of TriGuard and 30.8% of control subjects (P = 0.34). In the Per Treatment population (subjects with complete three-vessel cerebral coverage), TriGuard use was associated with greater freedom from new ischaemic brain lesions (26.9 vs. 11.5%), fewer new neurologic deficits detected by the National Institutes of Health Stroke Scale (3.1 vs. 15.4%), improved Montreal Cognitive Assessment (MoCA) scores, better performance on a delayed memory task (P = 0.028) at discharge, and a >2-fold increase in recovery of normal cognitive function (MoCA score >26) at 30 days.
TriGuard cerebral protection during TAVI is safe and complete cerebral vessel coverage was achieved in 89% of subjects. In this exploratory study, subjects undergoing protected TAVI had more freedom from ischaemic brain lesions, fewer neurologic deficits, and improved cognitive function in some domains at discharge and 30 days compared with controls.
This study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR).
TAVR has shown excellent safety and efficacy in ...patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves.
The Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up.
Between July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable.
All-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.
Display omitted
Cerebral embolization during transcatheter aortic valve implantation (TAVI) can lead to a spectrum of clinically relevant manifestations, ranging from overt stroke to mild neurologic or cognitive ...deficits and subclinical cerebral infarcts. This study sought to determine the frequency of neurologic injury, cerebral ischemic lesions, and cognitive dysfunction in subjects undergoing contemporary commercial TAVI in the United States. Neuro-TAVR is the first prospective, multicenter study to use serial systematic neurologic and cognitive assessments and diffusion-weighted magnetic resonance imaging (at 4 ± 2 days after procedure) to investigate the incidence and severity of neurologic injury after contemporary unprotected TAVI in the United States. A total of 44 consecutive patients underwent TAVI at 5 US sites. Diffusion-weighted magnetic resonance imaging lesions were detected in 94%, with a mean of 10.4 ± 15.3 lesions per subject and a median total lesion volume of 295 mm3 (interquartile range 71.6 to 799.6 mm3 ). New neurologic impairment (worsening in National Institutes of Health Stroke Scale score from baseline with new cerebral lesions) occurred in 22.6% (7 of 31) of subjects at discharge and 14.8% (4 of 27) at 30 days. In addition, cognitive decrements from baseline were identified by the Montreal Cognitive Assessment in 33% (12 of 36) of subjects at discharge and 41% (13 of 32) at 30 days. In conclusion, this contemporary cohort of US patients confirms that TAVI results in cerebral infarction in most patients and that 1 in 5 patients have measurable neurologic impairment and 1 in 3 patients have decrease in cognitive measures by Montreal Cognitive Assessment score after TAVI, reinforcing the need for methods to mitigate the risk of brain injury during TAVI.
Abstract Objectives This study evaluated the safety and effectiveness of self-expanding transcatheter aortic valve replacement (TAVR) in patients with surgical valve failure (SVF). Background ...Self-expanding TAVR is superior to medical therapy for patients with severe native aortic valve stenosis at increased surgical risk. Methods The CoreValve U.S. Expanded Use Study was a prospective, nonrandomized study that enrolled 233 patients with symptomatic SVF who were deemed unsuitable for reoperation. Patients were treated with self-expanding TAVR and evaluated for 30-day and 1-year outcomes after the procedure. An independent core laboratory was used to evaluate serial echocardiograms for valve hemodynamics and aortic regurgitation. Results SVF occurred through stenosis (56.4%), regurgitation (22.0%), or a combination (21.6%). A total of 227 patients underwent attempted TAVR and successful TAVR was achieved in 225 (99.1%) patients. Patients were elderly (76.7 ± 10.8 years), had a Society of Thoracic Surgeons Predicted Risk of Mortality score of 9.0 ± 6.7%, and were severely symptomatic (86.8% New York Heart Association functional class III or IV). The all-cause mortality rate was 2.2% at 30 days and 14.6% at 1 year; major stroke rate was 0.4% at 30 days and 1.8% at 1 year. Moderate aortic regurgitation occurred in 3.5% of patients at 30 days and 7.4% of patients at 1 year, with no severe aortic regurgitation. The rate of new permanent pacemaker implantation was 8.1% at 30 days and 11.0% at 1 year. The mean valve gradient was 17.0 ± 8.8 mm Hg at 30 days and 16.6 ± 8.9 mm Hg at 1 year. Factors significantly associated with higher discharge mean aortic gradients were surgical valve size, stenosis as modality of SVF, and presence of surgical valve prosthesis patient mismatch (all p < 0.001). Conclusions Self-expanding TAVR in patients with SVF at increased risk for surgery was associated with a low 1-year mortality and major stroke rate, significantly improved aortic valve hemodynamics, and low rates of moderate and no severe residual aortic regurgitation, with improved quality of life.
This study sought to evaluate the Medtronic Evolut PRO Transcatheter Aortic Valve System in patients with severe symptomatic aortic stenosis.
A next-generation self-expanding transcatheter aortic ...valve was designed with an external pericardial wrap with the intent to reduce paravalvular leak while maintaining the benefits of a low-profile, self-expanding, and repositionable supra-annular valve.
The Medtronic Evolut PRO Clinical Study included 60 patients undergoing transcatheter aortic valve replacement with the Evolut PRO valve at 8 investigational sites in the United States. Clinical outcomes at 30 days were evaluated using Valve Academic Research Consortium-2 criteria. The 2 primary safety endpoints were the incidence of all-cause mortality at 30 days and the incidence of disabling stroke at 30 days. The primary efficacy endpoint was the proportion of patients with no or trace prosthetic valve regurgitation at 30 days. An independent echocardiographic core laboratory (Mayo Clinic, Rochester, Minnesota) was used to adjudicate all echocardiographic assessments.
All 60 patients received the Evolut PRO valve. At 30 days, 1 patient (1.7%) died and 1 patient (1.7%) experienced a nonfatal disabling stroke. Paravalvular regurgitation at 30 days was absent or trace in 72.4% of patients and was mild in the remainder of patients, with no patients having worse than mild paravavlular leak. The mean atrioventricular gradient was 6.4 ± 2.1 mm Hg and effective orifice area was 2.0 ± 0.5 cm2 at 30 days.
The safety and efficacy results of this study support the use of the Evolut PRO System for the treatment of severe symptomatic aortic stenosis in patients who are at increased surgical risk, resulting in excellent hemodynamics and minimal paravalvular leak (The Medtronic TAVR 2.0 US Clinical Study; NCT02738853)
Display omitted
Background. Transcatheter aortic valve replacement (TAVR) is known to increase the incidence of conduction disturbances compared to surgical aortic valve replacement; however, there are limited data ...on the impact and duration of these conduction disturbances on longer term outcomes. Objective. To determine the differential impact of persistent versus nonpersistent new-onset conduction disturbances on TAVR-related complications and outcomes. Methods. This is a single-center retrospective analysis of 927 consecutive patients with aortic stenosis who underwent TAVR at Yale New Haven Hospital from July 2012 to August 2019. Patients with new-onset conduction disturbances within 7 days following TAVR were selected for this study. Persistent and nonpersistent disturbances were, respectively, defined as persisting or not persisting on all patient ECGs for up to 1.5 years after TAVR or until death. Results. Within 7 days after TAVR, conduction disturbances occurred in 42.3% (392/927) of the patients. Conduction disturbances persisted in 150 (38%) patients and did not persist in 187 (48%) patients, and 55 (14%) patients were excluded for having mixed (both persistent and nonpersistent) disturbances. Compared with nonpersistent disturbances, patients with persistent disturbances were more likely to receive a PPM within 7 days after the TAVR procedure (46.0% versus 4.3%, p<0.001) and had a greater unadjusted 1-year cardiac-related and all-cause mortality risk (HR 2.54, p=0.044 and HR 1.90, p=0.046, respectively). Conclusion. Persistent conduction disturbances were associated with a greater cardiac and all-cause mortality rate at one year following TAVR. Future research should investigate periprocedural factors to reduce persistent conduction disturbances and outcomes beyond one year follow-up.