The changing prevalence and patterns of tobacco use, the advent of novel nicotine delivery devices, and the development of new biomarkers prompted an update of the 2002 Society for Research on ...Nicotine and Tobacco (SRNT) report on whether and how to apply biomarker verification for tobacco use and abstinence.
The SRNT Treatment Research Network convened a group of investigators with expertise in tobacco biomarkers to update the recommendations of the 2002 SNRT Biochemical Verification Report.
Biochemical verification of tobacco use and abstinence increases scientific rigor and is recommended in clinical trials of smoking cessation, when feasible. Sources, appropriate biospecimens, cutpoints, time of detection windows and analytic methods for carbon monoxide, cotinine (including over the counter tests), total nicotine equivalents, minor tobacco alkaloids, and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol are reviewed, as well as biochemical approaches to distinguishing cigarette smoking from use of electronic nicotine delivery devices (ENDS).
Recommendations are provided for whether and how to use biochemical verification of tobacco use and abstinence. Guidelines are provided on which biomarkers to use, which biospecimens to use, optimal cutpoints, time windows to detection, and methodology for biochemical verifications. Use of combinations of biomarkers is recommended for assessment of ENDS use.
Biochemical verification increases scientific rigor, but there are drawbacks that need to be assessed to determine whether the benefits of biochemical verification outweigh the costs, including the cost of the assays, the feasibility of sample collection, the ability to draw clear conclusions based on the duration of abstinence, and the variability of the assay within the study population. This paper provides updated recommendations from the 2002 SRNT report on whether and how to use biochemical markers in determining tobacco use and abstinence.
The capability of electronic cigarette devices (e-cigs) to deliver nicotine is key to their potential to replace combustible cigarettes. We compared nicotine delivery and subjective effects ...associated with the use of two classes of e-cigarettes and cigarettes.
14 e-cigarette users were instructed to vape their own e-cigarette device every 20 seconds for 10 minutes while blood was drawn at 1, 2, 4, 6, 8, 10,12, and 15 minutes after initiating vaping. Users rated withdrawal symptoms and side effects before and after vaping. E-cigarette devices were classified as first-generation (same size as cigarette, no activation button) or advanced (larger than cigarette with an activation button). Separately, 10 cigarette smokers completed a similar protocol. Fisher's Exact Test and two-sided t-tests were used as appropriate to determine differences in outcomes between first-generation e-cigarette users, advanced e-cigarette users, and smokers.
Compared to first-generation devices, advanced devices were associated with greater serum nicotine Cmax (ng/ml) (11.5 v. 2.8, p = 0.0231) and greater nicotine boost (ng/ml) (10.8 v. 1.8, p = 0.0177). Overall, e-cigarettes users experienced a significant reduction in withdrawal and craving, although there were no significant differences between users of first-generation and advanced devices. Comparing e-cigarettes overall to cigarettes, cigarettes were associated with greater Cmax (25.9 v. 9.0, p = 0.0043) and greater nicotine boost (21.0 v. 8.2, p = 0.0128).
Advanced e-cigarettes delivered significantly more nicotine than first-generation devices but less than combustible cigarettes. Overall, e-cigarette use was associated with a reduction in withdrawal and craving with no reported side effects. The wide variation in nicotine absorption from different e-cigarette devices should be considered in studies of e-cigarettes for smoking cessation.
The U.S. Food and Drug Administration and the government of New Zealand have proposed a reduction of the nicotine content in cigarettes to very low levels. This study examined the potential effects ...of this regulation in smokers with affective disorders.
In a randomized controlled parallel group trial conducted at two sites in the USA (Penn State University, Hershey, PA and Massachusetts General Hospital, Boston, MA) 188 adult smokers with a current (n = 118) or lifetime (n = 70) anxiety or unipolar mood disorder, not planning to quit in the next 6 months, were randomly assigned (1:1) to smoke either Usual Nicotine Content (UNC) (11.6 mg nicotine/cigarette) research cigarettes, or Reduced Nicotine Content (RNC) research cigarettes where the nicotine content per cigarette was progressively reduced to 0.2 mg in five steps over 18 weeks. Participants were then offered the choice to either receive assistance to quit smoking, receive free research cigarettes, or resume using their own cigarette brand during a 12-week follow-up period. Main outcomes were biomarkers of nicotine and toxicant exposure, smoking behavior and dependence and severity of psychiatric symptoms. The pre-registered primary outcome was plasma cotinine.
A total of 143 (76.1%) randomized participants completed the randomized phase of the trial, 69 (73.4%) in the RNC group and 74 (78.8%) in the UNC group. After switching to the lowest nicotine content cigarettes, compared to smokers in the UNC group, at the last randomized visit the RNC group had significantly lower plasma cotinine (metabolite of nicotine): difference between groups, -175.7, 95% CI -218.3, -133.1 ng/ml. Urine NNAL (metabolite of NNK, a lung carcinogen), exhaled carbon-monoxide, cigarette consumption, and cigarette dependence were also significantly lower in the RNC group than the UNC group. No between-group differences were found on a range of other biomarkers (e.g. 8-isoprostanes) or health indicators (e.g. blood pressure), or on 5 different psychiatric questionnaires, including the Kessler K6 measure of psychological distress. At the end of the subsequent 12-week treatment choice phase, those randomized to the RNC group were more likely to have quit smoking, based on initial intent-to-treat sample, n = 188 (18.1% RNC v 4.3% UNC, p = 0.004).
Reducing nicotine content in cigarettes to very low levels reduces some toxicant exposures and cigarette addiction and increases smoking cessation in smokers with mood and/or anxiety disorders, without worsening mental health.
TRN: NCT01928758, registered August 21, 2013.
Unusual eye problem Beck, Daniel Edward Robert; Foulds, Jonathan Stewart
Emergency medicine journal : EMJ,
08/2019, Letnik:
36, Številka:
8
Journal Article
Many smokers report attempting to quit each year, yet most relapse, in part due to exposure to smoking-related cues. It is hypothesized that extinction of the cue-drug association could be ...facilitated through random nicotine delivery (RND), thus making it easier for smokers to quit. The current study aimed to evaluate the effects of RND on smoking cessation-related outcomes including cigarettes per day (CPD) and exhaled carbon monoxide (CO).
Participants were current smokers (>9 CPD) interested in quitting. Novel trans-mucosal, orally dissolving nicotine films, developed by Bionex Pharmaceuticals, were used in the study. The pharmacokinetic profile of these films was assessed in single (Experiment 1) and multiple-dose (Experiment 2) administrations prior to the smoking cessation study (Experiment 3). In Experiment 3, participants were randomized 1:1:1 to recieve 4 nicotine films per day of either: placebo delivery (0 mg), steady-state delivery (2 mg), or random nicotine delivery (RND) (0 mg or 4 mg). After two weeks, participants were advised to quit (target quit date, TQD) and were followed up 4 weeks later to collect CPD and CO and to measure dependence (Penn State Cigarette Dependence Index; PSCDI) and craving (Questionnaire of Smoking Urges; QSU-Brief). Means and frequencies were used to describe the data and repeated measures ANOVA was used to determine differences between groups.
The pharmacokinetic studies (Experiment 1 and 2) demonstrated that the films designed for this study delivered nicotine as expected, with the 4 mg film delivering a nicotine boost of approximately 12.4 ng/mL across both the single and the multiple dose administration studies. The films reduced craving for a cigarette and were well-tolerated, overall, and caused no changes in blood pressure or heart rate. Using these films in the cessation study (Experiment 3) (n = 45), there was a significant overall reduction in cigarettes smoked per day (CPD) and in exhaled CO, with no significant differences across groups (placebo, steady-state, RND). In addition, there were no group differences in dependence or craving. Adverse events included heartburn, hiccups, nausea, and to a lesser extent, vomiting and anxiety and there were no differences across groups.
Overall, this pilot study found that RND via orally dissolving films was feasible and well tolerated by participants. However, RND participants did not experience a greater reduction in self-reported CPD and exhaled CO, compared with participants in the steady-state and placebo delivery groups. Future studies to evaluate optimal RND parameters with larger sample sizes are needed to fully understand the effect of RND on smoking cessation-related outcomes.
Highlights • Less than 2% of adult e-cigarette users were never cigarette smokers
. • 63% of e-cig users who were never cigarette smokers had used other tobacco products
. • Studies of e-cig use ...should collect a full tobacco use history
. • Never cigarette smokers may use e-cigs to reduce other tobacco product use
.
Weight loss surgery (WLS) is an effective treatment for obesity and its associated conditions, but given the known benefits of preoperative tobacco abstinence on reducing postoperative complications, ...many WLS programs require tobacco abstention before surgery.
To evaluate the association between tobacco use and WLS program completion.
A 548-bed university hospital in Pennsylvania with a nationally accredited comprehensive WLS program.
A retrospective chart review was conducted to identify patients enrolled in a preoperative WLS program from January 1, 2013 to April 3, 2015. Participants were categorized as nontobacco users (NTU) or current tobacco users (CTU) based on self-report at assessment. Tobacco users were required to quit before scheduling surgery and abstinence was verified using serum cotinine (<7 ng/mL).
A total 620 patients enrolled in the preoperative program; 16.7% were tobacco users, 89% of whom were cigarette smokers. A total of 57.4% (n = 356) completed the program overall and there was a significant difference in completion by tobacco use status (62.4% NTU completed versus 32.7% CTU, P<.001). Among those who dropped out, 54% did so after attending 2 visits. In addition to not using tobacco, female gender, white race, and no prior psychiatric treatment were significant predictors of program completion (all P values< .02).
Current tobacco users dropped out of the preoperative program at almost twice the rate of nontobacco users. Weight loss surgery programs should offer evidence-based tobacco cessation interventions to improve access to care for obesity treatment.
This study is a systematic evaluation of a novel tobacco product, electronic cigarettes (ECIGs) using a two-site, four-arm, 6-month, parallel-group randomized controlled trial (RCT) with a follow-up ...to 9 months. Virginia Commonwealth University is the primary site and Penn State University is the secondary site. This RCT design is important because it is informed by analytical work, clinical laboratory results, and qualitative/quantitative findings regarding the specific ECIG products used.
Participants (N = 520) will be randomized across sites and must be healthy smokers of >9 cigarettes for at least one year, who have not had a quit attempt in the prior month, are not planning to quit in the next 6 months, and are interested in reducing cigarette intake. Participants will be randomized into one of four 24-week conditions: a cigarette substitute that does not produce an inhalable aerosol; or one of three ECIG conditions that differ by nicotine concentration 0, 8, or 36 mg/ml. Blocked randomization will be accomplished with a 1:1:1:1 ratio of condition assignments at each site. Specific aims are to: characterize ECIG influence on toxicants, biomarkers, health indicators, and disease risk; determine tobacco abstinence symptom and adverse event profile associated with real-world ECIG use; and examine the influence of ECIG use on conventional tobacco product use. Liquid nicotine concentration-related differences on these study outcomes are predicted. Participants and research staff in contact with participants will be blinded to the nicotine concentration in the ECIG conditions.
Results from this study will inform knowledge concerning ECIG use as well as demonstrate a model that may be applied to other novel tobacco products. The model of using prior empirical testing of ECIG devices should be considered in other RCT evaluations.
TRN: NCT02342795 , registered December 16, 2014.
Novel mRNA vaccines have been developed and were first distributed to high-risk individuals (including smokers) in the United States starting in December 2020 to combat the coronavirus (COVID-19) ...pandemic. Over one-half of the U.S. adult population has received at least 1 dose of a COVID-19 vaccine, but many others have reported hesitation about becoming vaccinated. We examined COVID-19 vaccine uptake and hesitancy from a convenience sample of Pennsylvanian adult smokers in April 2021, approximately 3 months after tobacco users were eligible to receive vaccination in the state. Participants (n = 231) were 23.4% male, 90.5% white, and had a mean age of 48.1 (SD = 11.9) years. All participants were current tobacco users, with the majority reporting current cigarette smoking (90.9%) with an average of 16 (SD = 8.1) cigarettes smoked per day. Nearly 60% (n = 137) reported receiving at least 1 dose of the vaccine and of those who did not (n = 94), 84% (n = 79) said they were somewhat or very unlikely to get a vaccine. Those who were unvaccinated were more likely to not consume news about COVID-19 (chi-square P-value < .01) and less likely to believe government news sources as reliable information for COVID-19 (chi-square P-value < .01). Qualitative responses among those who were vaccine hesitant expressed concerns about the lack of research on the vaccine, distrust of the safety of the vaccine, and fears about side effects. Understanding vaccine hesitancy among tobacco users can help develop targeted communication strategies and directly address concerns to promote vaccination among this population who may be at an increased risk of severe complications from COVID-19.