Marginal discrepancy influenced by the choice of processing material used for the ceramic laminate veneers needs to be explored further for better clinical application.
This study aimed to evaluate ...the amount of cervical and incisal marginal discrepancy associated with different ceramic laminate veneering materials.
This was an experimental, single-blinded,
trial.
Ten central incisors were prepared for laminate veneers with 2 mm uniform reduction and heavy chamfer finish line. Ceramic laminate veneers fabricated over the prepared teeth using four different processing materials were categorized into four groups as Group I - aluminous porcelain veneers, Group II - lithium disilicate ceramic veneers, Group III - lithium disilicate-leucite-based veneers, Group IV - zirconia-based ceramic veneers. The cervical and incisal marginal discrepancy was measured using a scanning electron microscope.
ANOVA and
Tukey honest significant difference (HSD) tests were used for statistical analysis.
The cervical and incisal marginal discrepancy for four groups was Group I - 114.6 ± 4.3 μm, 132.5 ± 6.5 μm, Group II - 86.1 ± 6.3 μm, 105.4 ± 5.3 μm, Group III - 71.4 ± 4.4 μm, 91.3 ± 4.7 μm, and Group IV - 123.1 ± 4.1 μm, 142.0 ± 5.4 μm. ANOVA and
Tukey HSD tests observed a statistically significant difference between the four test specimens with regard to cervical marginal discrepancy. The cervical and incisal marginal discrepancy scored
= 243.408,
< 0.001 and
= 180.844,
< 0.001, respectively.
This study concluded veneers fabricated using leucite reinforced lithium disilicate exhibited the least marginal discrepancy followed by lithium disilicate ceramic, aluminous porcelain, and zirconia-based ceramics. The marginal discrepancy was more in the incisal region than in the cervical region in all the groups.
ABSTRACT
Introduction
Various anthropometric measurements have been used to determine the size of maxillary anterior teeth. However, which anthropometric measurement is the most reliable indicator to ...determine the width of maxillary anterior teeth remains unclear.
Aims and objectives
To evaluate which anthropometric measurement is the most reliable indicator in determining the width of maxillary anterior teeth.
Materials and methods
An electronic search was conducted for scholarly articles discussing various anthropometric measurements used for determination of width of maxillary anterior teeth, written in English or translated into English listed with PubMed, Cochrane Library, ScienceDirect, Wiley Online Library, and Google scholar databases. The search strategy yielded 119 articles. Out of them, 70 were excluded following reading of abstract, and 49 were selected for full-text reading. Of these, 21 were excluded based on exclusion criteria. Finally, 28 articles were included for final search. Due to heterogenicity of studies, a meta-analysis was not performed.
Results
High degree of correlation was seen between interalar width (IAD), interpupillary distance (IPD), bizygomatic width (BW), and width of maxillary anterior teeth, in Indian population, whereas in Saudi population, intercanthal distance (ICD) has high degree of correlation to the width of maxillary anterior teeth, and in Brazilian (mulatto and blacks) population, high degree of correlation was seen between intercommissural width (ICOW) and width of maxillary anterior teeth.
Conclusion
The anthropometric measurement used depends on the population group in which it is being used. There is no single anthropometric measurement that can be used to determine the width of maxillary anterior teeth. Hence, more studies with large sample size and different population groups need to be conducted.
Clinical significance
In Indian population, high degree of correlation was seen between IAD, IPD, BW, and width of maxillary anterior teeth. The results of the previous study should be validated by including a large population size spread over entire Indian subcontinent. This would also help to generate multiplication factor for various anthropological measurements for use limited to the Indian population.
How to cite this article
Jain AR, Nallaswamy D, Ariga P, Ganapathy DM. Determination of Correlation of Width of Maxillary Anterior Teeth using Extraoral and Intraoral Factors in Indian Population: A Systematic Review. World J Dent 2018;9(1):68-75.
To assess up to date patient and doctor perceived costs of dental implant surgery among the Indian population as there is a lack of information regarding patients' awareness of dental implants. Two ...online questionnaire forms were sent over the internet to the Indian population and the Indian dentists and dental students regarding the knowledge, attitude and perception regarding the dental implant surgery for rehabilitation of a single missing tooth. Statistical analysis was then carried out using SPSS software version 23.0. Thirty-eight percent (P < 0.05) of the participants questioned the thought that implants require the same care as fixed prostheses, and thought it was a better option due to a major percent expecting an additional payment > 10,000 indian rupees. The expectations that patients have for an implant-supported set are high in contrast to their willingness to make additional payments. There are still misconceptions regarding costs, and these must be resolved individually in practice.
The aim of this study is to analyze and characterize the antimicrobial effect of cerium oxide nanoparticles (NP) synthesized using neem and ginger. Finely grounded neem and ginger powder were taken ...and mixed with distilled water. This mixture was then heated and filtered. Ammonium cerium nitrate dissolved in distilled water. Both the mixtures were mixed and stirred magnetically. A double-beam ultraviolet-visible spectrophotometer was used to monitor color changes. The extract was centrifuged at 8000 rpm for 15 min. The final pellet was powdered using a hot air oven at 70°C for 24 h. Visualization was done by transmission electron microscopy and spherical morphology was noted, with an average diameter of 5 nm, in aggregated form. The sample containing 100 mg of cerium oxide shows the most significant effect on the zone of inhibition of 11 mm of Staphylococcus aureus. The results obtained in the current study confirmed that CeO-NP possessed antioxidant and cytotoxic properties.
Deciphering the Role of MicroRNAs in Neuroblastoma Veeraraghavan, Vishnu Priya; Jayaraman, Selvaraj; Rengasamy, Gayathri ...
Molecules (Basel, Switzerland),
12/2021, Letnik:
27, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Neuroblastoma (NB) is a type of peripheral sympathetic nervous system cancer that most commonly affects children. It is caused by the improper differentiation of primitive neural crest cells during ...embryonic development. Although NB occurs for 8% of paediatric cancers, it accounts for 15% of cancer-related deaths. Despite a considerable increase in cytotoxic chemo- and radiotherapy, patients in advanced stages remain virtually incurable. Therefore, there is a desperate necessity for new treatment strategies to be investigated. Accumulating evidence suggested that microRNAs (miRNAs) are a class of non-coding RNAs with 19-25 nucleotides lengths and play a central role in the development of NB carcinogenesis. Fascinatingly, miRNA inhibitors have an antisense property that can inhibit miRNA function and suppress the activity of mature miRNA. However, many studies have addressed miRNA inhibition in the treatment of NB, but their molecular mechanisms and signalling pathways are yet to be analysed. In this study, we impart the current state of knowledge about the role of miRNA inhibition in the aetiology of NB.
It is of interest to compare the accuracy of three different impression techniques for a single tooth impression. We used 3 groups with 15 samples each in this study. Group 1: Putty and light body in ...a sectional stock tray; Group 2: Monophase and extra light body in a sectional stock tray; Group 3: Matrix impression technique. 15 impressions were taken of a prepared tooth on a typodont with each technique. The dimensions of the casts poured from these impression techniques were compared with the control typodont tooth. Data analysis shows that the matrix impression technique gave the best results in terms of dimensional study followed by monophase and extra light body impression technique and putty and light body impression technique gave the least accurate results. The results show that there is a statistically significant difference between the three impression techniques in terms of dimensional stability. Data analysis shows that the matrix impression technique gave the best results in terms of dimensional study followed by monophase and extra light body impression technique and putty and light body impression technique gave the least accurate results. The variations between the groups are within acceptable limits. Hence, it can be concluded that all the impression techniques will result in adequate dimensional stability and can be used in clinical scenarios.
Intraoral scanner (IOS) is a medical device used for capturing direct optical impressions and composed of a handheld camera (hardware), a computer and software. Digital impressions by intraoral ...scanning have become an increasingly popular alternative to conventional impressions. The aim of this systematic review is to assess the studies regarding the various available technologies for IOS and evaluate the most accurate IOS system for cases with multiple implants and identify the factors that can influence its accuracy.
A comprehensive electronic search was done in online databases, 'Pubmed', 'Google Scholar' and 'Cochrane' based on pre-determined eligibility criteria. In-vitro studies, In-vivo studies and Randomized controlled trials assessing the accuracy of intra-oral scanner technology were selected after thorough screening. The search strategy covered all studies published until February 2019 and yielded a total of 11 articles out of which 8 studies were determined to fulfil the inclusion criteria and were selected for this review. Data extraction from the included studies was conducted by the primary author and reviewed by the second author.
The information collected included sample size and population, study design, intervention, scanning methods, comparisons and outcome measures. 5 out of 8 included studies compared the distance deviation of the acquired scans from the true values while the remaining 3 studies gave trueness and precision values as the outcome variables. A forest plot on scanner precision displayed slightly higher precision levels in the TRIOS scanner compared to the other intraoral scanners.
Despite the limitations this study, it can be concluded that active wavefront sampling is more accurate than the other intraoral scanning technology employed by commercial scanners.
N20 omission or addition to the combination of an opioid and neuroleptic is referred to as neuroleptanalgesia and neuroleptanesthesia, respectively. Conscious sedation is the result of this ...evolution. The requirement for high-quality anesthesia that is also related with speedier recovery, improved comfort, and lower costs all support the concept of neuroleptanesthesia. A set of eight questions was formulated and circulated among the undergraduate and postgraduate students of Saveetha Dental College. Responses were collected and the data were entered into MS Excel sheet and transferred to SPSS for the analysis. Results were made into graphs and interpreted. In the present study, among the students who took part in the study, 36.3% of the students were postgraduates and 63.7% of them were undergraduates. About 45.2% of the students were not aware and 54.8% of the students were aware that neuroleptanalgesia refers to the combination of a potent sedative analgesic agent and a tranquillizer. Many of the students were not aware of what neuroleptic esthetic is and how it evolved. The current study showed that most students did not have enough knowledge about neurolept anesthesia. However, dentists should make efforts to improve knowledge, awareness of neurolept anesthesia for further advancement, and the need for high-quality anesthesia.
Long span base metal alloy fixed prosthesis and partial dental prosthesis frameworks most often require welding for better fit and adaptation. The type of metal alloys used and its effect on the weld ...strength of the prosthesis have to be investigated. The aim of the study is to comparatively analyze the weld strength of nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) base metal alloys when subjected to tungsten inert gas (TIG) welding. 10 nickel- and cobalt-based specimens were obtained by casting of castable resin patterns of dimension 25 mm × 3 mm × 1 mm. Welding of the samples was carried out using the Lampert PuK 2 welding equipment, and a three-point bend test using a universal testing machine was carried out to evaluate the weld strength of the specimens. Statistical analysis was carried out using the SPSS software version 23. Higher weld strength was observed in the Co-Cr alloy (mean = 898 MPa) than in the Ni-Cr alloy (mean = 690 MPa), when submitted to TIG welding (P < 0.05). TIG welding could be a better alternative for joining base metal alloys for long span edentulous cases, and cobalt-based alloys could be better alternatives to nickel-based alloys that usually tend to cause hypersensitivity reactions.