Scintillating bolometers for Double Beta Decay search Gironi, L.
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
05/2010, Letnik:
617, Številka:
1
Journal Article
Recenzirano
In the field of Double Beta Decay (DBD) searches, the use of high resolution detectors in which background can be actively discriminated is very appealing. Scintillating bolometers containing a ...Double Beta Decay emitter can largely fulfill this very interesting possibility. In this paper we present the latest results obtained with
CdWO
4
and
CaMoO
4
crystals. Moreover we report, for the first time, a very interesting feature of
CaMoO
4
bolometers: the possibility to discriminate
β
–
γ
events from those induced by
α
particles thanks to different thermal pulse shape.
The R&D project COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) aims to develop a cryogenic scintillating calorimeter using an undoped NaI-crystal as ...target for direct dark matter search. Dark matter particles interacting with the detector material generate both a phonon signal and scintillation light. While the phonon signal provides a precise determination of the deposited energy, the simultaneously measured scintillation light allows for particle identification on an event-by-event basis, a powerful tool to study material-dependent interactions, and to suppress backgrounds. Using the same target material as the DAMA/LIBRA collaboration, the COSINUS technique may offer a unique possibility to investigate and contribute information to the presently controversial situation in the dark matter sector. We report on the dedicated design planned for the NaI proof-of-principle detector and the objectives of using this detection technique in the light of direct dark matter detection.
Highlights • Melanoma and mesothelioma show a statistically significant co-occurrence in the general population. • Inherited melanoma and mesothelioma predisposition is shown by individual with ...germline mutations in BAP1. • This paper reports a patient with mesothelioma who carried a germline mutation in CDKN2A , a gene involved in familial melanoma. Thus, CDKN2A may also predispose to both these tumors. • This paper also suggests that other genes could be involved in this predisposition, because families with cases of both melanoma and mesothelioma and no mutations in either BAP1 or CDKN2A are presented. • Since BAP1 and CDKN2A are somatically mutated in both cancers, our results suggest that these tumors may share common stepwise carcinogenic pathways.
As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. ...However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of broken Cooper pairs, so-called quasiparticles. Here, we show that environmental radioactivity is a significant source of nonequilibrium quasiparticles. Moreover, ionizing radiation introduces time-correlated quasiparticle bursts in resonators on the same chip, further complicating quantum error correction. Operating in a deep-underground lead-shielded cryostat decreases the quasiparticle burst rate by a factor thirty and reduces dissipation up to a factor four, showcasing the importance of radiation abatement in future solid-state quantum hardware.
Radioactivity was recently discovered as a source of decoherence and correlated errors for the real-world implementation of superconducting quantum processors. In this work, we measure levels of ...radioactivity present in a typical laboratory environment (from muons, neutrons, and
γ
-rays emitted by naturally occurring radioactive isotopes) and in the most commonly used materials for the assembly and operation of state-of-the-art superconducting qubits. We present a GEANT-4 based simulation to predict the rate of impacts and the amount of energy released in a qubit chip from each of the mentioned sources. We finally propose mitigation strategies for the operation of next-generation qubits in a radio-pure environment.
Background model of the CUPID-0 experiment Azzolini, O.; Beeman, J. W.; Bellini, F. ...
European physical journal. C, Particles and fields,
07/2019, Letnik:
79, Številka:
7
Journal Article
Recenzirano
Odprti dostop
CUPID-0 is the first large mass array of enriched Zn
82
Se scintillating low temperature calorimeters, operated at LNGS since 2017. During its first scientific runs, CUPID-0 collected an exposure of ...9.95 kg year. Thanks to the excellent rejection of
α
particles, we attained the lowest background ever measured with thermal detectors in the energy region where we search for the signature of
82
Se
neutrinoless double beta decay. In this work we develop a model to reconstruct the CUPID-0 background over the whole energy range of experimental data. We identify the background sources exploiting their distinctive signatures and we assess their extremely low contribution down to
∼
10
-
4
counts/(keV kg year) in the region of interest for
82
Se
neutrinoless double beta decay search. This result represents a crucial step towards the comprehension of the background in experiments based on scintillating calorimeters and in next generation projects such as CUPID.
We present the performances of a 330 g zinc molybdate (ZnMoO
4
) crystal working as scintillating bolometer as a possible candidate for a next generation experiment to search for neutrinoless double ...beta decay of
100
Mo. The energy resolution, evaluated at the 2615 keV
γ
-line of
208
Tl, is 6.3 keV FWHM. The internal radioactive contaminations of the ZnMoO
4
were evaluated as <6 μBq/kg (
228
Th) and 27±6 μBq/kg (
226
Ra). We also present the results of the
α
vs
β
/
γ
discrimination, obtained through the scintillation light as well as through the study of the shape of the thermal signal alone.
The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the ...technology of cryogenic calorimeters is expected to be dominated by
α
particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn
82
Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the
α
background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.
ZnSe scintillating bolometers are good candidates for future Double Beta Decay searches, because of the
82Se high Q-value and thanks to the possibility of alpha background rejection on the basis of ...the scintillation signal. In this paper we report the characteristics and the anomalies observed in an extensive study of these devices. Among them, an unexpected high emission from alpha particles, accompanied with an unusual pattern of the light vs. heat scatter plot. The perspectives for the application of this kind of detectors to search for the Neutrinoless Double Beta Decay of
82Se are presented.
The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 Formula omitted enriched in ...Formula omittedSe and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of Formula omittedSe into the 0 Formula omitted, 2 Formula omitted and 2 Formula omitted excited states of Formula omittedKr with an exposure of 5.74 kg Formula omittedyr (2.24 Formula omitted10 Formula omitted emitters Formula omittedyr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Formula omitted( Formula omittedSe Formula omittedKr Formula omitted)8.55 Formula omitted10 Formula omitted yr Formula omitted, Formula omitted ( Formula omitted Se Formula omitted Kr Formula omitted) Formula omitted yr Formula omitted, Formula omitted( Formula omittedSe Formula omittedKr Formula omitted)8.25 Formula omitted10 Formula omitted yr Formula omitted (90 Formula omitted credible interval).