The NA48 collaboration is preparing a new experiment at CERN aiming to study
CP violation in the K
0-
K
0
system with an accuracy of 2 × 10
−4 in the parameter
R
e(ϵ′/ϵ). Decays in two
π
0's will be ...recorded by a quasi-homogeneous liquid krypton calorimeter. A liquid krypton calorimeter has been chosen to combine good energy, position and time resolution with precise charge calibration and long-term stability. The prototype calorimeter incorporating the final design of the electrode read-out structure is presented in this paper. An energy resolution of
≃3.5%
√E
with a constant term smaller than 0.5% has been obtained. The time resolution was found to be better than 300 ps above 15 GeV.
Vanadium dioxide is an intensively studied material that undergoes a temperature-induced metal-insulator phase transition accompanied by a large change in electrical resistivity. Electrical switches ...based on this material show promising properties in terms of speed and broadband operation. The exploration of the failure behavior and reliability of such devices is very important in view of their integration in practical electronic circuits. We performed systematic lifetime investigations of two-terminal switches based on the electrical activation of the metal-insulator transition in VO
2
thin films. The devices were integrated in coplanar microwave waveguides (CPWs) in series configuration. We detected the evolution of a 10 GHz microwave signal transmitted through the CPW, modulated by the activation of the VO
2
switches in both voltage- and current-controlled modes. We demonstrated enhanced lifetime operation of current-controlled VO
2
-based switching (more than 260 million cycles without failure) compared with the voltage-activated mode (breakdown at around 16 million activation cycles). The evolution of the electrical self-oscillations of a VO
2
-based switch induced in the current-operated mode is a subtle indicator of the material properties modification and can be used to monitor its behavior under various external stresses in sensor applications.
Further tests of lead tungstate crystal matrices made in high-energy electron beams in 1996, using new crystals, new APDs and an improved test setup confirm that an energy resolution of better than ...0.6% at 100
GeV can be obtained when the longitudinal uniformity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. It is shown that there is no loss of energy resolution after irradiation and it is demonstrated that the calibration change due to light loss can be tracked with a precision monitoring system. Successful tests with a preshower device, equipped with a silicon strip detector readout, are also described.
The performance of lead tungstate crystals using photomultipliers and Si avalanche photodiodes to detect the scintillation light has been studied using high energy electron, pion and muon beams at ...CERN. Results from tests carried out in 1993 and 1994 are presented. Good energy resolution has been obtained using photomultipliers. Some further development is required of crystals and avalanche photodiodes in order to achieve a performance, with avalanche photodiode readout, similar to that obtained using photomultipliers.
Forward calorimetry in the upgraded UA1 experiment
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/1989
Journal Article