NEDA—NEutron Detector Array Valiente-Dobón, J.J.; Jaworski, G.; Goasduff, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
05/2019, Letnik:
927
Journal Article
Recenzirano
Odprti dostop
The NEutron Detector Array, NEDA, will form the next generation neutron detection system that has been designed to be operated in conjunction with γ-ray arrays, such as the tracking-array AGATA, to ...aid nuclear spectroscopy studies. NEDA has been designed to be a versatile device, with high-detection efficiency, excellent neutron-γ discrimination, and high rate capabilities. It will be employed in physics campaigns in order to maximise the scientific output, making use of the different stable and radioactive ion beams available in Europe. The first implementation of the neutron detector array NEDA with AGATA 1π was realised at GANIL. This manuscript reviews the various aspects of NEDA.
Excited states in the Tz=0,−1 nuclei 62Ga and 62Ge were populated in direct reactions of relativistic radioactive ion beams at the RIBF. Coincident γ rays were measured with the DALI2+ array and ...uniquely assigned to the A=62 isobars. In addition, 62Ge was also studied independently at JYFL-ACCLAB using the 24Mg(40Ca,2n)62Ge fusion-evaporation reaction. The first excited T=1,Jπ=2+ states in 62Ga and 62Ge were identified at 979(1) and 965(1) keV, respectively, resolving discrepant interpretations in the literature. States beyond the first 2+ state in 62Ge were also identified for the first time in the present work. The results are compared with shell-model calculations in the fp model space. Mirror and triplet energy differences are analyzed in terms of individual charge-symmetry and charge-independence breaking contributions. The MED results confirm the shrinkage of the p-orbits' radii when they are occupied by at least one nucleon on average.
.
Lifetimes of high-spin states have been measured in the semi-magic
(
N
=
50
)
nucleus
94
Ru. Excited states in
94
Ru were populated in the
58
Ni(
40
Ca, 4
p
)
94
Ru
*
fusion-evaporation reaction at ...the Grand Accélérateur National d’Ions Lourds (GANIL) accelerator complex. DSAM lifetime analysis was performed on the Doppler broadened line shapes in energy spectra obtained from
γ
-rays emitted while the residual nuclei were slowing down in a thick 6mg/cm^2 metallic
58
Ni target. In total eight excited-state lifetimes in the angular momentum range
I
=
(
13
-
20
)
ℏ
have been measured, five of which were determined for the first time. The corresponding
B
(
M
1) and
B
(
E
2) reduced transition strengths are discussed within the framework of large-scale shell model calculations to study the contribution of different particle-hole configurations, in particular for analyzing contributions from core-excited configurations.
A new neutron multiplicity filter NEDA, after a decade of design, R&D and construction, was employed in its first physics campaign with the AGATA spectrometer. Properties and performance of the ...array are discussed.
Energy differences between analogue states in the T=1/2 ^{23}Mg-^{23}Na mirror nuclei have been measured along the rotational yrast bands. This allows us to search for effects arising from ...isospin-symmetry-breaking interactions (ISB) and/or shape changes. Data are interpreted in the shell model framework following the method successfully applied to nuclei in the f_{7/2} shell. It is shown that the introduction of a schematic ISB interaction of the same type of that used in the f_{7/2} shell is needed to reproduce the data. An alternative novel description, applied here for the first time, relies on the use of an effective interaction deduced from a realistic charge-dependent chiral nucleon-nucleon potential. This analysis provides two important results: (i) The mirror energy differences give direct insight into the nuclear skin; (ii) the skin changes along the rotational bands are strongly correlated with the difference between the neutron and proton occupations of the s_{1/2} "halo" orbit.
The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line ...processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and γ standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or γ rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron-γ discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events.
In this work we present a comparison between the two liquid scintillators BC-501A and BC-537 in terms of their performance regarding the pulse-shape discrimination between neutrons and γ rays. ...Special emphasis is put on the application of artificial neural networks. The results show a systematically higher γ-ray rejection ratio for BC-501A compared to BC-537 applying the commonly used charge comparison method. Using the artificial neural network approach the discrimination quality was improved to more than 95% rejection efficiency of γ rays over the energy range 150 to 1000 keV for both BC-501A and BC-537. However, due to the larger light output of BC-501A compared to BC-537, neutrons could be identified in BC-501A using artificial neural networks down to a recoil proton energy of 800 keV compared to a recoil deuteron energy of 1200 keV for BC-537. We conclude that using artificial neural networks it is possible to obtain the same γ-ray rejection quality from both BC-501A and BC-537 for neutrons above a low-energy threshold. This threshold is, however, lower for BC-501A, which is important for nuclear structure spectroscopy experiments of rare reaction channels where low-energy interactions dominates.
Energy differences between analogue states in the T = 1/2 Mg-23-Na-23 mirror nuclei have been measured along the rotational yrast bands. This allows us to search for effects arising from ...isospin-symmetrybreaking interactions (ISB) and/or shape changes. Data are interpreted in the shell model framework following the method successfully applied to nuclei in the f(7/2) shell. It is shown that the introduction of a schematic ISB interaction of the same type of that used in the f(7/2) shell is needed to reproduce the data. An alternative novel description, applied here for the first time, relies on the use of an effective interaction deduced from a realistic charge-dependent chiral nucleon-nucleon potential. This analysis provides two important results: (i) The mirror energy differences give direct insight into the nuclear skin; (ii) the skin changes along the rotational bands are strongly correlated with the difference between the neutron and proton occupations of the s(1/2) "halo" orbit.
A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid ...scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501.