We report on the search for dark matter weakly interacting massive particles (WIMPs) in the mass range below 10 GeV=c2 from the analysis of the entire dataset acquired with a low-radioactivity argon ...target by the DarkSide-50 experiment at Laboratori Nazionali del Gran Sasso. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately model the background rate and spectra down to 0.06 keVer. A 90% C.L. exclusion limit for the spin-independent cross section of 3 GeV=c2 mass WIMP on nucleons is set at 6 × 10-43 cm2, about a factor 10 better than the previous DarkSide-50 limit. This analysis extends the exclusion region for spin-independent dark matter interactions below the current experimental constraints in the 1.2, 3.6 GeV=c2 WIMP mass range.
The performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation ...cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting.
Intrinsic
40
K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. This work ...explores two methodologies in parallel for the reduction of
40
K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.
We present a detailed report on sterile neutrino oscillation and 235Uν¯e energy spectrum measurement results from the PROSPECT experiment at the highly enriched High Flux Isotope Reactor (HFIR) at ...Oak Ridge National Laboratory. In 96 calendar days of data taken at an average baseline distance of 7.9 m from the center of the 85 MW HFIR core, the PROSPECT detector has observed more than 50,000 interactions of νe produced in beta decays of 235U fission products. New limits on the oscillation of ν¯e to light sterile neutrinos have been set by comparing the detected energy spectra of ten reactor-detector baselines between 6.7 and 9.2 meters. Measured differences in energy spectra between baselines show no statistically significant indication of ν¯e to sterile neutrino oscillation and disfavor the reactor antineutrino anomaly best-fit point at the 2.5σ confidence level. The reported 235U ν¯e energy spectrum measurement shows excellent agreement with energy spectrum models generated via conversion of the measured 235U beta spectrum, with a χ2/d.o.f. of 31/31. PROSPECT is able to disfavor at 2.4σ confidence level the hypothesis that 235U ν¯e are solely responsible for spectrum discrepancies between model and data obtained at commercial reactor cores. A data-model deviation in PROSPECT similar to that observed by commercial core experiments is preferred with respect to no observed deviation, at a 2.2σ confidence level.
Therapeutic angiogenesis, a new experimental strategy for the treatment of vascular insufficiency, uses the administration of mediators known to induce vascular development in embryogenesis to induce ...neovascularization of ischemic adult tissues. This report summarizes a phase I clinical experience with a gene-therapy strategy that used an E1(-)E3(-) adenovirus (Ad) gene-transfer vector expressing human vascular endothelial growth factor (VEGF) 121 cDNA (Ad(GV)VEGF121.10) to induce therapeutic angiogenesis in the myocardium of individuals with clinically significant coronary artery disease.
Ad(GV)VEGF121.10 was administered to 21 individuals by direct myocardial injection into an area of reversible ischemia either as an adjunct to conventional coronary artery bypass grafting (group A, n=15) or as sole therapy via a minithoracotomy (group B, n=6). There was no evidence of systemic or cardiac-related adverse events related to vector administration. In both groups, coronary angiography and stress sestamibi scan assessment of wall motion 30 days after therapy suggested improvement in the area of vector administration. All patients reported improvement in angina class after therapy. In group B, in which gene transfer was the only therapy, treadmill exercise assessment suggested improvement in most individuals.
The data are consistent with the concept that direct myocardial administration of Ad(GV)VEGF121.10 to individuals with clinically significant coronary artery disease appears to be well tolerated, and initiation of phase II evaluation of this therapy is warranted.
Human height is a classic, highly heritable quantitative trait. To begin to identify genetic variants influencing height, we examined genome-wide association data from 4,921 individuals. Common ...variants in the HMGA2 oncogene, exemplified by rs1042725, were associated with height (P = 4 × 10−8). HMGA2 is also a strong biological candidate for height, as rare, severe mutations in this gene alter body size in mice and humans, so we tested rs1042725 in additional samples. We confirmed the association in 19,064 adults from four further studies (P = 3 × 10−11, overall P = 4 × 10−16, including the genome-wide association data). We also observed the association in children (P = 1 × 10−6, N = 6,827) and a tall/short case-control study (P = 4 × 10−6, N = 3,207). We estimate that rs1042725 explains ∼0.3% of population variation in height (∼0.4 cm increased adult height per C allele). There are few examples of common genetic variants reproducibly associated with human quantitativetraits; these results represent, to our knowledge, the first consistently replicated association with adult and childhood height.
Finding unequivocal evidence of dark matter interactions in a particle detector is a major goal of research in physics. Liquid argon time projection chambers offer a path to probe Weakly Interacting ...Massive Particles scattering cross sections on nuclei down to the so-called neutrino floor, in a mass range from a few GeV to hundreds of TeV. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all types of events observed in the detector, is essential for the optimal design of the new experiment. In this article, we report on a specific set of events, namely, standard two-pulse scintillation–ionization signals with a third small amplitude pulse, occurring within the 440μs data acquisition window of standard events. Some of these events are due to the photoionization of the TPC cathode. We compare our results with those published by collaborations using liquid xenon time projection chambers, which observed a similar phenomenon, and, in particular, with a recent paper by the LUX Collaboration (D.S. Akerib et al. Phys.Rev.D 102, 092004 (2020)) From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths of around 128 nm, in liquid argon. Also, both experiments observe events likely related to the photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be an order of magnitude lower in DarkSide-50 than in LUX.
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here ...reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain super(39) Ar at a level reduced by a factor (1.4+ or -0.2)x10 super(3) relative to atmospheric argon. We report a background-free null result from (2616+ or -43)kgd of data, accumulated over 70.9 live days. When combined with our previous search using an atmospheric argon, the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section, based on zero events found in the WIMP search regions, is 2.0x10 super(-44)cm super(2)(8.6x10-44cm super(2), 8.0x10 super(-43)cm super(2)) for a WIMP mass of 100GeV/c super(2)(1TeV/c super(2), 10TeV/c super(2)).