This paper presents the results of a clinical, observational, descriptive study to quantify the use patterns of electronic cigarette users in their natural environment. Previously published work ...regarding puff topography has been widely indirect in nature, and qualitative rather than quantitative, with the exception of three studies conducted in a laboratory environment for limited amounts of time. The current study quantifies the variation in puffing behaviors among users as well as the variation for a given user throughout the course of a day. Puff topography characteristics computed for each puffing session by each subject include the number of subject puffs per puffing session, the mean puff duration per session, the mean puff flow rate per session, the mean puff volume per session, and the cumulative puff volume per session. The same puff topography characteristics are computed across all puffing sessions by each single subject and across all subjects in the study cohort. Results indicate significant inter-subject variability with regard to puffing topography, suggesting that a range of representative puffing topography patterns should be used to drive machine-puffed electronic cigarette aerosol evaluation systems.
Protocols for testing and reporting emissions of Harmful and Potentially Harmful Constituents (HPHCs) from electronic cigarettes (e-cigs) are lacking. The premise of this study is that multi-path ...relationships may be developed to describe interactions between product characteristics, use behavior and emissions to develop appropriate protocols for tobacco product regulatory compliance testing.
This study proposes a framework consisting of three component terms: HPHC mass concentration, HPHC mass ratio and total particulate mass (TPM) concentration. The framework informs experiments to investigate dependence of aerosol emissions from five electronic cigarettes spanning several design generations and three e-liquids for six repeated trials at each of ten flow conditions.
Results are reported for TPM concentration as a function of flow conditions spanning the range of natural environment topography observed in prior studies. An empirical correlation describing TPM concentration as a function of flow conditions and coil power setting (6, 7.5 and 10 watts) for the Innokin iTaste MVP 2.0 vaporizer with Innokin iClear 30 dual coil tank is presented. Additional results document the impact of flow conditions and wick and coil design on TPM concentration through comparison of the Innokin iClear 30 (upper coil, capillary action wick) and the Innokin iClear X.I (lower coil, gravity fed wick) operated at 7.5 watts. The impact of e-liquid on TPM concentration is illustrated by comparing emissions from an NJOY Vape Pen filled with AVAIL Arctic Blast, Tobacco Row, and Mardi Gras e-liquids. TPM concentration is shown to depend upon flow conditions across a range of e-cigarette product designs including cig-a-like, pen-style, box-mod and emergent disposable-cartridge style devices.
A framework provides a foundation for reporting emissions across a variety of e-cigs, e-liquids and research laboratories. The study demonstrates TPM concentration is a function of topography behavior (i.e. puff flow rate and puff duration) for varying device operating power and product characteristics.
The FTC, in 2008, rescinded its 1966 guidance regarding use of the Cambridge Filter Method, noting the yields from the method are relatively poor indicators of tar, nicotine, and carbon monoxide ...exposure. This article proposes a set of puffing conditions for cigarette emissions testing, with the goal of developing product-specific emissions characterizations which can subsequently be used to realistically model the yield of particulate matter and constituents to the mouth of a smoker, while accounting for the actual puffing behavior of the smoker.
Synthesis of data was conducted on data collected from a prior one-week observation of 26 adult cigarette smokers, using their usual brand cigarette in each smokers' natural environment including the puff flow rate, duration, volume and time of day of each puff taken were recorded with a cigarette topography monitor. Data was analyzed to determine the empirical joint probability function and cumulative distribution function of mean puff flow rate and puff duration. The joint CDF was used to define an emissions topography protocol using concepts common to computational grid generation.
Analysis of 8,250 cigarette puffs indicated the middle 95% of mean puff flow rates varied between 15 and 121 mL/s while the middle 95% of puff duration varied from 0.55 to 3.42 s.
Thirteen conditions of varying mean puff flow rate and puff duration are proposed for a comprehensive cigarette emissions topography protocol. The proposed protocol addresses inadequacies associated with common machine-puffing profiles used for generating cigarette emissions.
Electronic Nicotine Delivery Systems (ENDS) offer an alternate means to consume nicotine in a variety of flavored aerosols. Data are needed to better understand the impact of flavors on use behavior. ...A natural environment observational study was conducted on experienced ENDS users to measure the effect of e-liquid flavor on topography and consumption behavior. The RIT wPUMTM monitor was used to record to record the date and time and puff topography (flow rate, volume, duration) for every puff taken by N = 34 participants over the course of two weeks. All participants used tobacco flavor for one week, and either berry or menthol flavor for one week. Results provide strong evidence that flavor affects the topography behaviors of mean puff flow rate and mean puff volume, and there is insufficient evidence to support an influence of flavor on mean puff duration and mean puff interval. There was insufficient evidence, due to the low power associated with the limited number of observation days, to establish a relationship between flavor and cumulative consumption behavior. While the results indicate that an effect may be evident, additional observation days are required to establish significance.
Results of an observational, descriptive study quantifying topography characteristics of twenty first generation electronic nicotine delivery system users in their natural environment for a one week ...observation period are presented. The study quantifies inter-participant variation in puffing topography between users and the intra-participant variation for each user observed during one week of use in their natural environment. Puff topography characteristics presented for each user include mean puff duration, flow rate and volume for each participant, along with descriptive statistics of each quantity. Exposure characteristics including the number of vaping sessions, total number of puffs and cumulative volume of aerosol generated from ENDS use (e-liquid aerosol) are reported for each participant for a one week exposure period and an effective daily average exposure. Significant inter-participant and intra-participant variation in puff topography was observed. The observed range of natural use environment characteristics is used to propose a set of topography protocols for use as command inputs to drive machine-puffed electronic nicotine delivery systems in a controlled laboratory environment.
This study introduces and demonstrates a comprehensive, accurate, unbiased approach to robust quantitative comparison of electronic nicotine delivery systems (ENDS) appropriate for establishing ...substantial equivalence (or lack thereof) between inhaled nicotine products. The approach is demonstrated across a family of thirteen pen- and pod-style ENDS products. Methods employed consist of formulating a robust emissions surface regression model, quantifying the empirical accuracy of the model as applied to each product, evaluating relationships between product design characteristics and maximum emissions characteristics, and presenting results in formats useful to researchers, regulators, and consumers. Results provide a response surface to characterize emissions (total particulate matter and constituents thereof) from each ENDS appropriate for use in a computer model and for conducting quantitative exposure comparisons between products. Results demonstrate that emissions vary as a function of puff duration, flow rate, e-liquid composition, and device operating power. Further, results indicate that regulating design characteristics of ENDS devices and consumables may not achieve desired public health outcomes; it is more effective to regulate maximum permissible emissions directly. Three emissions outcome measures (yield per puff, mass concentration, and constituent mass ratio) are recommended for adoption as standard quantities for reporting by manufacturers and research laboratories. The approach provides a means of: (a) quantifying and comparing maximal emissions from ENDS products spanning their entire operating envelope, (b) comparative evaluation of ENDS devices and consumable design characteristics, and (c) establishing comparative equivalence of maximal emissions from ENDS. A consumer-oriented product emissions dashboard is proposed for comparative evaluation of ENDS exposure potential. Maximum achievable power dissipated in the coil of ENDS is identified as a potentially effective regulatory parameter.
Silver nanoparticles (AgNPs) possess unique characteristics ideal for enhancing device sensitivity, primarily due to their high surface-to-volume ratio facilitating heightened interaction with ...analytes. Integrating AgNPs into polymers or carbon-based materials results in nanocomposites with synergistic properties, enabling the detection of minute changes in the environment across various applications. In this study, we investigate the adsorption kinetics of AgNPs within multilayered layer-by-layer (LbL) structures, specifically examining the impact of AgNPs concentration in the LbL film formation that is further explored as sensing units in an impedimetric microfluidic e-tongue. Although absorption kinetic studies are infrequent, they are crucial to optimize the AgNPs adsorption and distribution within LbL structures, significantly influencing upcoming applications. Through systematic variation of AgNPs concentration within identical LbL architectures, we applied the films as sensing units in a microfluidic e-tongue capable of distinguishing food enhancers sharing the umami taste profile. Across all tested scenarios, our approach consistently achieves robust sample separation, evidenced by silhouette coefficient, principal component analyses, and long-term stability. This work contributes to exploring controlled nanomaterial-based developments, emphasizing the importance of precise parameter control for enhanced sensor performance across diverse analytical applications.
Many Electronic Nicotine Delivery Systems (ENDS) employ integrated sensors to detect user puffing behavior and activate the heating coil to initiate aerosol generation. The minimum puff flow rate and ...duration at which the ENDS device begins to generate aerosol are important parameters in quantifying the viable operating envelope of the device and are essential to formulating a design of experiments for comprehensive emissions characterization. An accurate and unbiased method for quantifying the flow condition operating envelope of ENDS is needed to quantify product characteristics across research laboratories. This study reports an accurate, unbiased method for measuring the minimum and maximum aerosolization puff flow rate and duration of seven pod-style, four pen-style and two disposable ENDS. The minimum aerosolization flow rate ranged from 2.5 to 23 (mL/s) and the minimum aerosolization duration ranged from 0.5 to 1.0 (s) across the ENDS studied. The maximum aerosolization flow rate was defined to be when the onset of liquid aspiration was evident, at flow rates ranging from 50 to 88 (mL/s). Results are presented which provide preliminary estimates for the effective maximum aerosolization flow rate and duration envelope of each ENDS. The variation in operating envelope observed between ENDS products of differing design by various manufacturers has implications for development of standardized emissions testing protocols and data reporting required for regulatory approval of new products.
3D Printed e-Tongue Gaál, Gabriel; da Silva, Tatiana A; Gaál, Vladimir ...
Frontiers in chemistry,
05/2018, Letnik:
6
Journal Article
Recenzirano
Odprti dostop
Nowadays, one of the biggest issues addressed to electronic sensor fabrication is the build-up of efficient electrodes as an alternative way to the expensive, complex and multistage processes ...required by traditional techniques. Printed electronics arises as an interesting alternative to fulfill this task due to the simplicity and speed to stamp electrodes on various surfaces. Within this context, the Fused Deposition Modeling 3D printing is an emerging, cost-effective and alternative technology to fabricate complex structures that potentiates several fields with more creative ideas and new materials for a rapid prototyping of devices. We show here the fabrication of interdigitated electrodes using a standard home-made CoreXY 3D printer using transparent and graphene-based PLA filaments. Macro 3D printed electrodes were easily assembled within 6 min with outstanding reproducibility. The electrodes were also functionalized with different nanostructured thin films via dip-coating Layer-by-Layer technique to develop a 3D printed e-tongue setup. As a proof of concept, the printed e-tongue was applied to soil analysis. A control soil sample was enriched with several macro-nutrients to the plants (N, P, K, S, Mg, and Ca) and the discrimination was done by electrical impedance spectroscopy of water solution of the soil samples. The data was analyzed by Principal Component Analysis and the 3D printed sensor distinguished clearly all enriched samples despite the complexity of the soil chemical composition. The 3D printed e-tongue successfully used in soil analysis encourages further investments in developing new sensory tools for precision agriculture and other fields exploiting the simplicity and flexibility offered by the 3D printing techniques.
Lack of biomimicry in geometry and flow conditions of emissions systems for analytical testing and biological exposure has led to fundamental limitations, including a poor understanding of dose ...delivered to specific airway locations. This work characterizes mass distribution of a JUUL® brand e-cigarette in a Biomimetic Aerosol Exposure System (BAES).
A combination of mass balance, direct measurements, and inferences based on direct measurements were used to characterize regional and local dose as a function of system flow path configuration and emissions topography profile.
Doses produced by the emissions topography profile with only puffing were significantly different from profiles with clean air inhalation following puffs. Mass characterization results support that dose can be manipulated using flow path geometry. Local and regional deposition was mapped throughout the system.
We estimate the fraction of yield to the mouth deposited at several locations throughout the system for a variety of puffing and respiration topographies and show that emissions topography profile and system flow path geometry affect dose. This work provides proof-of-concept for assessing mass distribution as a function of aerosol generator (e-cigarette product), user airway geometry, and inhalation and puffing topography.