The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization ...orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.
The Daya Bay experiment has observed correlations between reactor core fuel evolution and changes in the reactor antineutrino flux and energy spectrum. Four antineutrino detectors in two experimental ...halls were used to identify 2.2 million inverse beta decays (IBDs) over 1230 days spanning multiple fuel cycles for each of six 2.9 GW_{th} reactor cores at the Daya Bay and Ling Ao nuclear power plants. Using detector data spanning effective ^{239}Pu fission fractions F_{239} from 0.25 to 0.35, Daya Bay measures an average IBD yield σover ¯_{f} of (5.90±0.13)×10^{-43} cm^{2}/fission and a fuel-dependent variation in the IBD yield, dσ_{f}/dF_{239}, of (-1.86±0.18)×10^{-43} cm^{2}/fission. This observation rejects the hypothesis of a constant antineutrino flux as a function of the ^{239}Pu fission fraction at 10 standard deviations. The variation in IBD yield is found to be energy dependent, rejecting the hypothesis of a constant antineutrino energy spectrum at 5.1 standard deviations. While measurements of the evolution in the IBD spectrum show general agreement with predictions from recent reactor models, the measured evolution in total IBD yield disagrees with recent predictions at 3.1σ. This discrepancy indicates that an overall deficit in the measured flux with respect to predictions does not result from equal fractional deficits from the primary fission isotopes ^{235}U, ^{239}Pu, ^{238}U, and ^{241}Pu. Based on measured IBD yield variations, yields of (6.17±0.17) and (4.27±0.26)×10^{-43} cm^{2}/fission have been determined for the two dominant fission parent isotopes ^{235}U and ^{239}Pu. A 7.8% discrepancy between the observed and predicted ^{235}U yields suggests that this isotope may be the primary contributor to the reactor antineutrino anomaly.
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass p-type point-contact germanium detector of the CDEX-1B ...experiment at the China Jinping Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2-yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus (χ-N) spin-independent cross sections as function of WIMP mass (m_{χ}) at 90% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at >99.99% and 98% C.L., respectively. These results correspond to the best sensitivity at m_{χ}<6 GeV/c^{2} among WIMP AM measurements to date.
We report constraints on the dark photon effective kinetic mixing parameter (κ) with data taken from two p-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping ...Underground Laboratory. The 90% confidence level upper limits on κ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (m_{V}) from 10 to 300 eV/c^{2} in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90% confidence level with m_{V} from 0.1 to 4.0 keV/c^{2} are set from 449.6 kg-day data, with a minimum of κ=1.3×10^{-15} at m_{V}=200 eV/c^{2}.
Summary
Background
Tong‐Xie‐Yao‐Fang (TXYF) is a Chinese herbal formula for treating chronic diarrhoea accompanied by abdominal pain. The results were inconsistent in previous trials examining its ...effect.
Aim
To study the efficacy of TXYF granules for treating diarrhoea‐predominant irritable bowel syndrome (IBS‐D).
Methods
We performed a double‐blind, placebo‐controlled randomised trial and enrolled 160 participants with IBS‐D. The participants had VAS scores ≥3 cm in IBS‐D global symptoms and ≥2 days in a week with abdominal pain and loose stools (Bristol score 5, 6 or 7). They were randomly assigned to received TXYF or placebo during a treatment period of 4 weeks, and they were followed up for 8 weeks after treatment. The primary outcome was adequate relief of IBS‐D global symptoms for at least 2 of 4 weeks during weeks 1‐4. Secondary outcomes included mean weekly VAS scores of IBS‐D major symptoms, mean weekly stool frequency, mean weekly Bristol score, and adverse events.
Results
155 of 160 patients completed the trial. We found a significantly higher rate of adequate relief of global symptoms in TXFY group during weeks 1 to 4 (57.5% vs 37.5%, χ2 = 5.6391, P = 0.017); logistic regression analysis showed a similar result (OR 2.2, 95% CI 1.2‐4.4, P = 0.016). Most of the secondary outcomes showed superiority of TXYF over placebo in weekly assessment from week 3 to week 7. The adverse event rate was low in both groups (3.8% vs 3.8%, P = 1.000).
Conclusion
During a 4 week trial, TXFY granules were superior to placebo in controlling symptoms of IBS‐D.
Linked ContentThis article is linked to Vitta and Sayuk and Chen et al papers. To view these articles visit https://doi.org/10.1111/apt.14902 and https://doi.org/10.1111/apt.14906.
ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).
Many patients who require allogeneic hematopoietic stem cell transplantation (allo-HSCT) lack a human leukocyte antigen (HLA)-matched donor. Here, we report a protocol for haploidentical allo-HSCT ...that combines granulocyte-colony stimulating factor primed bone marrow (G-BM) and peripheral blood stem cells (PBSC) without in vitro T-cell depletion (TCD). In this study, 171 patients, including 86 in high-risk group, underwent transplantation from haploidentical family donors. All patients achieved sustained, full donor chimerism. One hundred and eleven patients were alive in remission at a median of 682 (253-1502) days. The cumulative incidence of grade III-IV acute graft-versus-host disease (GVHD) was 23% and that of extensive chronic GVHD, 47%; these were not influenced by HLA disparity. Patients younger than 15 years had less grade III-IV acute GVHD than older patients (P=0.044). The 2-year probability of relapse was 12% for standard-risk disease and 39% for high-risk disease. The 2-year probability of leukemia-free survival (LFS) was 68% for standard-risk patients and 42% for high-risk patients (P=0.0009). Grade III-IV acute GVHD was associated with better LFS (P=0.0017). The results require confirmation and show that G-BM combined with PBSC from haploidentical family donors, without in vitro TCD, may be used as a good source of stem cells for allo-HSCT.