The Muon g-2 Experiment at Fermilab (E989) will measure the muon magnetic anomaly with unprecedented precision (0.14 ppm), which yields a factor of 4 improvement with respect to the previous ...measurements at Brookhaven National Laboratory (BNL) (E821). To achieve this goal, the relative response of each calorimeter channel must be calibrated and monitored at a level better than <inline-formula> <tex-math notation="LaTeX">10^{-3} </tex-math></inline-formula> in the time window of the muon fill. The calibration system uses a laser source and photodetectors. The data acquisition (DAQ) of the system is designed around two field-programmable gate array (FPGA)-based boards and a custom crate bus. The front-end board manages the photodetector operation and signal processing and performs a first-level data concentration task. Up to 12 FPGA boards can be housed in a 6U crate. A readout master controls the boards, implements event-building functionalities, manages the monitoring interface, and facilitates calibration and debugging tasks. A gigabit-ethernet interface is used to transfer data to the on-line farm for storage and further processing. Presently, the system is working at Fermi National Accelerator Laboratory (FNAL). In this article, we present the DAQ system design, run control user interface, and system evaluation.
A comparison of BGO and BSO crystals used in the dual-readout mode Akchurin, N.; Bedeschi, F.; Cardini, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/2011, Letnik:
640, Številka:
1
Journal Article
Recenzirano
We report on a systematic study of the properties of two high-
Z scintillating crystals, bismuth germanate (BGO) and bismuth silicate (BSO), in view of the possible application of such crystals in ...dual-readout calorimeters. Whereas the light attenuation characteristics of both crystals are about the same, BSO offers a considerably higher Cherenkov light yield, and with a given UV filter the separation between the Cherenkov and scintillation signals is substantially better in this crystal.
Data handling, reconstruction, and simulation for the KLOE experiment Ambrosino, F.; Antonelli, A.; Antonelli, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2004, Letnik:
534, Številka:
3
Journal Article
Recenzirano
Odprti dostop
The broad physics program of the KLOE experiment is based on the high event rate at the Frascati φ
factory, and calls for an up-to-date system for data acquisition and processing. In this review of ...the KLOE offline environment, the architecture of the data-processing system and the programs developed for data reconstruction and Monte Carlo simulation are described, as well as the various procedures used for data handling and transfer between the different components of the system.
We present a new measurement of the positive muon magnetic anomaly, a_{μ}≡(g_{μ}-2)/2, from the Fermilab Muon g-2 Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times ...the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, ωover ˜_{p}^{'}, and of the anomalous precession frequency corrected for beam dynamics effects, ω_{a}. From the ratio ω_{a}/ωover ˜_{p}^{'}, together with precisely determined external parameters, we determine a_{μ}=116 592 057(25)×10^{-11} (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain a_{μ}(FNAL)=116 592 055(24)×10^{-11} (0.20 ppm). The new experimental world average is a_{μ}(exp)=116 592 059(22)×10^{-11} (0.19 ppm), which represents a factor of 2 improvement in precision.