COVID-19 is diagnosed via detection of SARS-CoV-2 RNA using real time reverse-transcriptase polymerase chain reaction (rtRT-PCR). Performance of many SARS-CoV-2 rtRT-PCR assays is not entirely known ...due to the lack of a gold standard. We sought to evaluate the false negative rate (FNR) and sensitivity of our laboratory-developed SARS-CoV-2 rtRT-PCR targeting the envelope (E) and RNA-dependent RNA-polymerase (RdRp) genes.
SARS-CoV-2 rtRT-PCR results at the Public Health Laboratory (Alberta, Canada) from January 21 to April 18, 2020 were reviewed to identify patients with an initial negative rtRT-PCR followed by a positive result on repeat testing within 14 days (defined as discordant results). Negative samples from these discordant specimens were re-tested using three alternate rtRT-PCR assays (targeting the E gene and N1/N2 regions of the nucleocapsid genes) to assess for false negative (FN) results.
During the time period specified, 95,919 patients (100,001 samples) were tested for SARS-CoV-2. Of these, 49 patients were found to have discordant results including 49 positive and 52 negative swabs. Repeat testing of 52 negative swabs found five FNs (from five separate patients). Assuming 100% specificity of the diagnostic assay, the FNR and sensitivity in this group of patients with discordant testing was 9.3% (95% CI 1.5-17.0%) and 90.7% (95% CI 82.6-98.9%) respectively.
Studies to understand the FNR of routinely used assays are important to confirm adequate clinical performance. In this study, most FN results were due to low amounts of SARS-CoV-2 virus concentrations in patients with multiple specimens collected during different stages of infection. Post-test clinical evaluation of each patient is advised to ensure that rtRT-PCR results are not the only factor in excluding COVID-19.
Coronavirus disease (COVID) serological tests are essential to determine the overall seroprevalence of a population and to facilitate exposure estimates within that population. We performed a ...head-to-head assessment of enzyme immunoassays (EIAs) and point-of-care lateral flow assays (POCTs) to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies. Demographics, symptoms, comorbidities, treatment, and mortality of patients whose sera were used were also reviewed. Six EIAs (Abbott, Affinity, Bio-Rad, DiaSorin, Euroimmun, and Roche) and six POCTs (BTNX, Biolidics, Deep Blue, Genrui, Getein BioTech, and Innovita) were evaluated for the detection of SARS-CoV-2 antibodies in known COVID-19-infected individuals. Sensitivity of EIAs ranged from 50 to 100%, with only four assays having overall sensitivities of >95% after 21 days after symptom onset. Notably, cross-reactivity with other respiratory viruses (parainfluenza virus PIV-4
= 5, human metapneumovirus hMPV
= 3, rhinovirus/enterovirus
= 1, CoV-229E
= 2, CoV-NL63
= 2, and CoV-OC43
= 2) was observed; however, overall specificity of EIAs was good (92 to 100%; all but one assay had specificity above 95%). POCTs were 0 to 100% sensitive >21 days after onset, with specificity ranging from 96 to 100%. However, many POCTs had faint banding and were often difficult to interpret. Serology assays can detect SARS-CoV-2 antibodies as early as 10 days after symptom onset. Serology assays vary in their sensitivity based on the marker (IgA/IgM versus IgG versus total) and by manufacturer; however, overall only 4 EIAs and 4 POCTs had sensitivities of >95% >21 days after symptom onset. Cross-reactivity with other seasonal coronaviruses is of concern. Serology assays should not be used for the diagnosis of acute infection but rather in carefully designed serosurveys to facilitate understanding of seroprevalence in a population and to identify previous exposure to SARS-CoV-2.
Measurement of SARS-CoV-2 antibody seropositivity is important to accurately understand exposure to infection and/or vaccination in specific populations. This study aimed to estimate the serologic ...response to SARS-CoV-2 virus infection and vaccination in children in Calgary, Alberta over a two-year period.
Children with or without prior SARS-CoV-2 infections, were enrolled in Calgary, Canada in 2020. Venous blood was sampled 4 times from July 2020 to April 2022 for SARS-CoV-2 nucleocapsid and spike antibodies. Demographic and clinical information was obtained including SARS-CoV-2 testing results and vaccination records.
1035 children were enrolled and 88.9% completed all 4 visits; median age 9 years (IQR: 5,13); 519 (50.1%) female; and 815 (78.7%) Caucasian. Before enrolment, 118 (11.4%) had confirmed or probable SARS-CoV-2. By April 2022, 39.5% of previously uninfected participants had a SARS-CoV-2 infection. Nucleocapsid antibody seropositivity declined to 16.4% of all infected children after more than 200 days post diagnosis. Spike antibodies remained elevated in 93.6% of unvaccinated infected children after more than 200 days post diagnosis. By April 2022, 408 (95.6%) children 12 years and older had received 2 or more vaccine doses, and 241 (61.6%) 5 to 11 year-old children had received 2 vaccine doses. At that time, all 685 vaccinated children had spike antibodies, compared with 94/176 (53.4%) of unvaccinated children.
In our population, after the first peak of Omicron variant infections and introduction of COVID-19 vaccines for children, all vaccinated children, but just over one-half of unvaccinated children, had SARS-CoV-2 spike antibodies indicating infection and/or vaccination, highlighting the benefit of vaccination. It is not yet known whether a high proportion of seropositivity at the present time predicts sustained population-level protection against future SARS-CoV-2 transmission, infection or severe COVID-19 outcomes in children.
Abstract
As COVID-19 waves continue to spread worldwide, demand for a portable, inexpensive and convenient biosensor to determine community immune/infection status is increasing. Here we describe an ...impedance-based affinity biosensor using Interdigitated Electrode (IDE) arrays to detect antibodies to SARS-CoV-2 in serum. We created the biosensor by functionalizing the IDEs’ surface with abaculaovirus-expressed and purified Spike (S) protein to bind anti-SARS CoV-2antibodies. Gold nanoparticles (GNP) fused to protein G were used to probe for bound antibodies. An ELISA assay using horseradish peroxidase-protein G to probe for bound IgG confirmed that the purified S protein bound a commercial source of anti-SARS-CoV-2 antibodies specifically and bound anti-SARS-CoV-2 antibodies in COVID-19 positive serum. Then we demonstrated that our biosensor could detect anti-SARS-CoV-2 antibodies with 72% sensitivity in 2 h. Using GNP-protein G, the affinity biosensor had increased impedance changes with COVID-19positive serum and minimal or decreased impedance changes with negative serum. This demonstrated that our biosensor could discriminate between COVID-19 positive and negative sera, which were further improved using poly(vinyl alcohol)as a blocking agent.
Many severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology tests have proven to be less accurate than expected and do not assess antibody function as neutralizing, correlating with ...protection from reinfection. A new assay technology measuring the interaction of the purified SARS-CoV-2 spike protein receptor binding domain (RBD) with the extracellular domain of the human angiotensin-converting enzyme 2 (hACE2) receptor detects these important antibodies. The cPass surrogate virus neutralization test (sVNT), compared directly with eight SARS-CoV-2 IgG serology and two live-cell neutralization tests, gives similar or improved accuracy for qualitative delineation between positive and negative individuals in a fast, scalable, and high-throughput assay. The combined data support the cPass sVNT as a tool for highly accurate SARS-CoV-2 immunity surveillance of infected/recovered and/or vaccinated individuals as well as drug and convalescent-phase donor screening. The data also preview a novel application for the cPass sVNT in calibrating the stringency of live-cell neutralization tests and its use in longitudinal testing of recovered and/or vaccinated patients.
We present a three patient case series of infants who presented to the pediatric emergency department with fever, bulging anterior fontanelle (BAF), and an omicron variant COVID-19 infection. All ...patients had a benign course, none developed meningitis, and all had symptom resolution after two days. Considerations for neuroimaging and lumbar puncture are discussed. This case series adds to the previously published case reports of infants with COVID-19, fever and BAF and further describes a variant in the presenting symptomology of COVID-19 infection in infants under 12 months. Acute and primary care providers who treat infants should consider COVID-19 testing in patients who are well appearing, with fever and BAF.
Coronavirus disease 2019 (COVID-19) has caused significant global morbidity and mortality. The serology test that detects antibodies against the disease causative agent, the severe acute respiratory ...syndrome coronavirus 2 (SARS-CoV-2), has often neglected value in supporting immunization policies and therapeutic decision-making. The ELISA-based antibody test is time-consuming and bulky. This work described a gold micro-interdigitated electrodes (IDE) biosensor for COVID antibody detection based on Electrochemical Impedance Spectroscopy (EIS) responses. The IDE architecture allows easy surface modification with the viral structure protein, Spike (S) protein, in the gap of the electrode digits to selectively capture anti-S antibodies in buffer solutions or human sera. Two strategies were employed to resolve the low sensitivity issue of non-faradic impedimetric sensors and the sensor fouling phenomenon when using the serum. One uses secondary antibody-gold nanoparticle (AuNP) conjugates to further distinguish anti-S antibodies from the non-specific binding and obtain a more significant impedance change. The second strategy consists of increasing the concentration of target antibodies in the gap of IDEs by inducing an AC electrokinetic effect such as dielectrophoresis (DEP). AuNP and DEP methods reached a limit of detection of 200 ng/mL and 2 μg/mL, respectively using purified antibodies in buffer, while the DEP method achieved a faster testing time of only 30 min. Both strategies could qualitatively distinguish COVID-19 antibody-positive and -negative sera. Our work, especially the impedimetric detection of COVID-19 antibodies under the assistance of the DEP force presents a promising path toward rapid, point-of-care solutions for COVID-19 serology tests.
Kanji and Saxinger cite that hunting, butchering and consuming of uncooked caribou meat as part of a traditional diet is common in Northern Canada, and Canadian physicians should be aware of the ...potential for Brucella suis zoonosis. Brucella species zoonoses, which may also occur after consumption of unpasteurized dairy products, present as either acute or long-term infection; focal infection, for example, infection of implantable devices, is common. If physicians suspect infection with Brucella species, the microbiology laboratory should be notified to ensure specimens are processed appropriately to reduce risk of infection in laboratory workers.