Test of the HAPD light sensor for the Belle II Aerogel RICH Yusa, Y.; Adachi, I.; Dolenec, R. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2017, Letnik:
876
Journal Article
Recenzirano
The Aerogel Ring-Imaging Cherenkov detector (ARICH) is being installed in the endcap region of Belle II spectrometer to identify particles from B meson decays by detecting the Cherenkov ring image ...from aerogel radiators. To detect single photons, high-sensitive photon detector which has wide effective area (∼70mm × 70mm), a Hybrid Avalanche Photo Detector (HAPD), has been developed in a collaboration with Hamamatsu K.K. The HAPD consists of hybrid structure of a vacuum tube and an avalanche photodiode (APD). It can be operated in 1.5T magnetic field of the spectrometer and withstands the radiation levels expected in the Belle II experiment. There are two steps of electric pulse amplification: acceleration of photo-electron in electric field in the vacuum tube part and electron avalanche in the APD part resulting in total gain of order 105. For the ARICH, we use 420 HAPDs in total. Before installing them, we performed quality assessment studies such as measurements of dark current, noise level, signal-to-noise ratio and two-dimensional scan with laser illumination. We also measured quantum efficiency of the photocathode. During the HAPD performance tests in the magnetic field, we observed very large signal pulses which cause long dead time of the readout electronics in some of the HAPDs. We have carried out a number of studies to understand this phenomenon, and have found a way to mitigate it and suppress the degradation of the ARICH performance. In this report, we will show a summary of the HAPD performance and quality assessment measurements including validation in the magnetic field for all of the HAPDs manufactured for the ARICH in the Belle II.
We have developed a RICH counter as a new forward particle identification device for the Belle II experiment. As a Cherenkov radiator in this counter, a dual aerogel layer combination consisting of ...two refractive indicies, n=1.045 and 1.055, is employed. Mass production of these aerogel tiles has been done during 2013–2014 with new method improved by Chiba group. Optical qualities for them have been examined. The refractive indices of the obtained tiles were found to be in good agreement with our expectations, and the transparencies were high enough to be used for the RICH radiator.
Development of slow control system for the Belle II ARICH counter Yonenaga, M.; Adachi, I.; Dolenec, R. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2017, Letnik:
876
Journal Article
Recenzirano
A slow control system (SCS) for the Aerogel Ring Imaging Cherenkov (ARICH) counter in the Belle II experiment was newly developed and coded in the development frameworks of the Belle II DAQ software. ...The ARICH is based on 420 Hybrid Avalanche Photo-Detectors (HAPDs). Each HAPD has 144 pixels to be readout and requires 6 power supply (PS) channels, therefore a total number of 2520 PS channels and 60,480 pixels have to be configured and controlled. Graphical User Interfaces (GUIs) with detector oriented view and device oriented view, were also implemented to ease the detector operation. The ARICH SCS is in operation for detector construction and cosmic rays tests. The paper describes the detailed features of the SCS and preliminary results of operation of a reduced set of hardware which confirm the scalability to the full detector.
Development of the ARICH monitor system for the Belle II experiment Hataya, K.; Adachi, I.; Dolenec, R. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2017, Letnik:
876
Journal Article
Recenzirano
The Belle II detector is under construction at KEK in Japan. In the forward endcap region of the Belle II detector, particle identification (PID) is performed by the Aerogel Ring Imaging Cherenkov ...(ARICH) counter composed of aerogel tiles and 144-channel Hybrid Avalanche Photo-Detectors (HAPDs). The photon detection efficiency of the photosensor is important for a stable operation of the ARICH. To examine the performance of the HAPDs periodically, a monitor system using scattered photons injected by optical fibers is being developed. In this paper, we report the test using the prototype monitor system and the tests with a partially built ARICH detector.
Exact information on the relative stopping power (RSP) of the high-energy proton in the human body is necessary to precisely control radiation dose and position in proton beam therapy. RSP has been ...estimated by converting the X-ray computed tomography (CT) information. However, it causes up to 5% uncertainty in the RSP measurements because of the fundamental difference between the X-ray and proton interaction. Therefore, this study investigates a scheme of the RSP distribution measurement in the human body with a combination of X-ray CT and proton radiography with beam injection to a single direction. We studied the accuracy of the RSP measurement using GEANT4 simulation with silicon trackers, crystal calorimeter, and proton beam. The RSP accuracy has been generally measured below 1% from the reference values for simple objects with multi cylindrical shapes. The simulation results present the requirements of a proton tracking system on the spatial resolution and the acquisition rate. We developed a tracking detector prototype consisting of double-sided silicon strip detectors and amplifier–shaper–discriminator LSI chips. We evaluated the performance with an 80 MeV proton beam in Cyclotron and Radioisotope Center, Tohoku University. It succeeded in reconstructing a proton trajectory with 160 kHz and fulfilled the requirements to realize the proposed scheme. Furthermore, this study describes the detailed study of the scheme of the RSP measurement and the beam test of the tracking system prototype.
In the forward end-cap of the Belle II spectrometer, a proximity focusing Ring Imaging Cherenkov counter with an aerogel radiator will be installed. The detector will occupy a limited space inside ...solenoid magnet with longitudinal field of 1.5T. It will consist of a double layer aerogel radiator, an expansion volume and a photon detector. 420 Hamamatsu hybrid avalanche photo sensors with 144 channels each will be used to read out single Cherenkov photons with high efficiency. More than 60,000 analog signals will be digitized and processed in the front end electronics and send to the unified experiment data acquisition system.
The detector components have been successfully produced and are now being installed in the spectrometer. Tested before on the bench, they are currently being installed in the mechanical frame. Part of the detector have been commissioned and connected to the acquisition system to register the cosmic ray particles. The first preliminary results are in accordance with previous expectations.
We expect an excellent performance of the device which will allow at least a 4σ separation of pions from kaons in the experiment kinematic region from 0.5GeV/c to 4GeV/c.
Recent developments in software for the Belle II aerogel RICH Šantelj, L.; Adachi, I.; Dolenec, R. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2017, Letnik:
876
Journal Article
Recenzirano
For the Belle II spectrometer a proximity focusing RICH counter with an aerogel radiator (ARICH) will be employed as a PID system in the forward end-cap region of the spectrometer. The detector will ...provide about 4σ separation of pions and kaons up to momenta of 3.5GeV/c, at the kinematic limits of the experiment. We present the up-to-date status of the ARICH simulation and reconstruction software, focusing on the recent improvements of the reconstruction algorithms and detector description in the Geant4 simulation. In addition, as a demonstration of detector readout software functionality we show the first cosmic ray Cherenkov rings observed in the ARICH.
The proximity-focusing Aerogel Ring-Imaging Cherenkov detector (ARICH) has been designed to separate kaons from pions in the forward end-cap of the Belle II spectrometer. The detector will be placed ...in 1.5T magnetic field and must have immunity to it. In ARICH R&D, we solve the problem with new equipment called Hybrid Avalanche Photo-Detector (HAPD) which developed by Hamamatsu Photonics. Recently the production of about 500 HAPDs was completed. We test HAPDs in magnetic field in KEK. We found some HAPDs have significant amount of dead time, which reaches up to 30% in the worst case. The dead time is caused by very large (more than 10,000times larger than a single photon signal) and frequent (∼5Hz) signals, which make electronics paralysed. The huge signals are observed in about 30% of HAPDs. To identify the origin and understand the mechanism, we perform some extra test of HAPDs. We find a strange dependence of the huge signals to the APD bias voltage. If we reduce the bias voltage applied to one of the 4 APDs by 10V, the frequency of the huge signals is much reduced. On the other hand, if we reduce the voltage of all the 4 HAPDs, huge signals do not decrease, or even increase in some case. We also find the huge signals seems to be related to the vacuum inside HAPD. We present about the observation of the huge signals of HAPDs in the magnetic field, and our strategy to manage it.
•On a PMT device called HAPD, strange and huge electric pulses are observed.•These pulses occur only in magnetic field.•There are two method to suppress them, bias voltage drop and “getter reactivation”.•The hypothesis about the origin of the pulses is surface flash over effect.
Studies of a hybrid avalanche photo-detector in magnetic field Šantelj, L.; Adachi, I.; Hataya, K. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2017, Letnik:
845
Journal Article
Recenzirano
For the Belle II spectrometer a proximity focusing RICH counter with an aerogel radiator (ARICH) will be employed as a PID system in the forward endcap region of the spectrometer. The main challenge ...was the development of a reliable multichannel sensor for single photons that operates in the high magnetic field of the spectrometer (1.5T) and withstands the radiation levels expected at the experiment. A 144-channel Hybrid Avalanche Photo-Detector (HAPD) was developed with Hamamatsu Photonics K.K. and the mass production of ∼480 HAPDs was completed recently. While our first tests of HAPD performance in the magnetic field (before mass production) showed no issues, we lately observed a presence of very large signal pulses (∼5000×single photon signal), generated internally within about 20% of HAPDs, while operating in the magnetic field. The rate of these pulses varies from sample to sample. These pulses impact the HAPD performance in two ways: they introduce periods of dead time and, in some cases, damage to the front-end electronics was observed. Here we present conditions under which such large pulses are generated, their properties and impact on HAPD performance, and discuss possible mechanism of their origin.