Purpose: Lepidopteran insect cells are known to exhibit very high radioresistance. Although very effective DNA excision-repair has been proposed as a contributing factor, a detailed understanding of ...insect cell radiation responses has not yet been obtained. Therefore, the study was carried out to understand the in vitro radiation responses of Sf9 lepidopteran cells.
Materials and methods: Exponentially growing asynchronous Sf9 cells (derived from ovaries of Spodoptera frugiperda) were exposed to gamma-radiation doses of 2-200 Gy. Cell survival, growth inhibition, cell cycle progression delay, alterations in cell morphology as well as induction of DNA damage, micronuclei and apoptosis were studied at various post-irradiation time intervals.
Results: Biphasic survival response curves were obtained with D0 rising from 20 Gy (at doses ≤60 Gy) to 85 Gy (between 60 and 200 Gy), corroborating earlier reports on lepidopteran cells. An additional downward deviation at 2 Gy indicated a hypersensitive response. Dose-dependent growth inhibition with a transient G2 delay starting 12 h and extending up to 48-96 h was observed at doses of 10-200 Gy, while a brief G1 S transition delay was observed only at higher doses (≥100 Gy). Significant DNA damage was detected only at 20 Gy and higher doses, in contrast with human cells that showed similar damage at 2 Gy. Interestingly, micronuclei were not induced at any of the doses tested, although spontaneous micronucleation was evident in <1% of cells. Lack of micronucleus induction even at doses that induced significant DNA damage and a transient G2 block (20-50 Gy) strongly indicated a role of holocentric lepidopteran chromosomes. Apoptosis was detected only in a small proportion of cells (3%) exposed to 200 Gy, and cell nucleus size and granularity increased by 72-96 h post-irradiation in a dose-dependent manner. Sf9 nucleoids extracted at 2 M NaCl showed higher compactness than the nucleoids prepared from human cells.
Conclusions: It is clearly shown that lepidopteran cells are highly resistant to the induction of DNA damage and micronuclei, and display very low induction of apoptosis at doses up to 200 Gy. While the lack of micronucleus induction seems to be primarily due to the holocentric nature of their chromosomes, certain unique signalling pathways might be responsible for the low induction of apoptosis. Factors causing protection of Sf9 cellular DNA from radiation-induced damage are presently being investigated.
Multicellular spheroids, an appropriate in vitro system for simulating 3-D tumor micro-milieu can be used for evaluating and predicting tumor response to therapeutic agents including metabolic ...inhibitors. However, detailed understanding of the nature, distribution and sensitivity/responses of cellular sub-populations to potential therapeutic agents/strategies is required for using this unique model with optimal precision. Spheroid characteristics may also vary considerably with the origin and type of cell line used, and thorough characterization of viable and dissociated glioma cell spheroids is not yet completely known. In order to evaluate in vivo responses of gliomas to various therapeutic strategies, especially the metabolic inhibitors capable of penetrating the blood brain barrier, we have characterized continuously growing spheroids of a human glioma cell line (BMG-1) with respect to organization, growth, viability, cell survival, cell death, metabolic and mitochondrial status, oxidative stress and radiation response using microscopy, flow cytometry and enzymatic assays. Spheroids were fed daily with fresh medium in order to maintain nutrient supply to outer cellular layers while hypoxia/necrosis developed in the innermost cells of enlarging spheroids.
Volume of spheroids, fed daily with fresh medium, increased exponentially during 7-28 days of growth through three population doublings. Proportion of G1-phase cells was higher (approximately 60%) than exponentially growing monolayer cells (approximately 48%). A significant fraction of S-phase cells turned metabolically inactive (disengaged in DNA synthesis) with increasing age of the spheroids, unlike in quiescent monolayer cultures, where the fraction of S-phase cells was less than 5%. With increasing spheroid size, increasing sub-populations of cells became non-viable and entered apoptosis or necrosis revealed by Annexin-V-FITC/PI staining. PI positive (necrotic) cells were not confined to the centre of the spheroid, but distributed at certain discrete foci. Average glucose consumption and lactate production were 2-3 folds higher in viable spheroid cells compared to monolayer cells, implying a compensatory increase in glycolysis possibly due to hypoxic environment. HIF-1alpha was expressed only in spheroids and increased in an age-dependent manner, whereas c-Myc (known to induce apoptosis in glucose-deprived cells) levels were three times higher than monolayer cells. Mitochondrial mass and activity decreased significantly during first 14 days of growth but increased with age, and were not associated with increase in ROS levels. Bcl-2 and Bax levels were higher (approximately 2 folds) than monolayers, while the ratio (Bcl/Bax) remained unaltered. Radiation-induced oxidative stress was considerably less in spheroids as compared to monolayers, and corresponded well with increase in radioresistance demonstrated by the clonogenic assay, similar to hypoxia induced radioresistance observed in tumors.
Development of S-negative cells and reduced endogenous and radiation-induced ROS coupled with higher levels of anti (Bcl2) as well as pro (Bax) apoptotic regulators observed in spheroids suggest the intricate/complex nature of endogenous as well as induced stress resistance that could exist in tumors, which contribute to the treatment resistance.
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background ...negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. Here, we characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments.
Weakly interacting massive particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a ...measurement of the scintillation timing characteristics of liquid xenon in the LUX dark matter detector and develop a pulse shape discriminant to be used for particle identification. To accurately measure the timing characteristics, we develop a template-fitting method to reconstruct the detection times of photons. Analyzing calibration data collected during the 2013–2016 LUX WIMP search, we provide a new measurement of the singlet-to-triplet scintillation ratio for electron recoils (ER) below 46 keV, and we make, to our knowledge, a first-ever measurement of the NR singlet-to-triplet ratio at recoil energies below 74 keV. We exploit the difference of the photon time spectra for NR and ER events by using a prompt fraction discrimination parameter, which is optimized using calibration data to have the least number of ER events that occur in a 50% NR acceptance region. We then demonstrate how this discriminant can be used in conjunction with the charge-to-light discrimination to possibly improve the signal-to-noise ratio for nuclear recoils.
We report an absolute calibration of the ionization yields (Qy) and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric ...field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy Xe127 electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of weakly interacting massive particles. The sequence of gamma-ray and x-ray cascades associated with I127 deexcitations produces clearly identified two-vertex events in the LUX detector. We observe the K-(binding energy, 33.2 keV), L-(5.2 keV), M-(1.1 keV), and N-(186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil in situ measurements that have been explored in liquid xenon.
LUX was the first dark matter experiment to use a Kr83m calibration source. In this paper, we describe the source preparation and injection. We also present several Kr83m calibration applications in ...the context of the 2013 LUX exposure, including the measurement of temporal and spatial variation in scintillation and charge signal amplitudes, and several methods to understand the electric field within the time projection chamber.