Coronavirus disease (COVID-19) is a global pandemic. Studies in the radiology literature have suggested that CT might be sufficiently sensitive and specific in diagnosing COVID-19 when used in lieu ...of a reverse transcription-polymerase chain reaction test; however, this suggestion runs counter to current society guidelines. The purpose of this article is to critically review some of the most frequently cited studies on the use of CT for detecting COVID-19.
To date, the radiology literature on COVID-19 has consisted of limited retrospective studies that do not substantiate the use of CT as a diagnostic test for COVID-19.
Organization, characterized by fibroblast proliferation, is a common and nearly universal response to lung injury whether it is focal or diffuse. Despite the vast range of injurious agents, the ...lung's response to injury is quite limited, with a similar pattern of reaction seen radiologically and histologically regardless of the underlying cause. Although there is a tendency to divide organization into distinct entities, the underlying injury to the alveolar epithelial basement membrane is a uniting factor in these processes. This pattern of lung injury is seen in the organizing phase of diffuse alveolar damage, organizing pneumonia (OP), acute fibrinous and organizing pneumonia, and certain types of fibrotic lung disease. In addition, although organization can heal without significant injury, in some instances it progresses to fibrosis, which can be severe. When fibrosis due to organization is present, other histologic and imaging patterns, such as those seen in nonspecific interstitial pneumonia, can develop, reflecting that fibrosis can be a sequela of organization. This article reviews the histologic and radiologic findings of organization in lung injury due to diffuse alveolar damage, OP, and acute fibrinous and organizing pneumonia and helps radiologists understand that the histologic and radiologic findings depend on the degree of injury and the subsequent healing response.
Mosaic attenuation is a commonly encountered pattern on computed tomography that is defined as heterogeneous areas of differing lung attenuation. This heterogeneous pattern of attenuation is the ...result of diverse causes that include diseases of the small airways, pulmonary vasculature, alveoli, and interstitium, alone or in combination. Small airways disease can be a primary disorder, such as respiratory bronchiolitis or constrictive bronchiolitis, or be part of parenchymal lung disease, such as hypersensitivity pneumonitis, or large airways disease, such as bronchiectasis and asthma. Vascular causes resulting in mosaic attenuation are typically chronic thromboembolic pulmonary hypertension, which is characterized by organizing thrombi in the elastic pulmonary arteries, or pulmonary arterial hypertension, a heterogeneous group of diseases affecting the distal pulmonary arterioles. Diffuse ground-glass opacity can result in a mosaic pattern related to a number of processes in acute (eg, infection, pulmonary edema), subacute (eg, organizing pneumonia), or chronic (eg, fibrotic diseases) settings. Imaging clues that can assist the radiologist in pinpointing a diagnosis include evidence of large airway involvement, cardiovascular abnormalities, septal thickening, signs of fibrosis, and demonstration of airtrapping at expiratory imaging.
Smooth muscles of the lower esophageal sphincter (LES) and skeletal muscle of the crural diaphragm (esophagus hiatus) provide the sphincter mechanisms at the esophagogastric junction (EGJ). We ...investigated differences in the 3-dimensional (3D) pressure profile of the LES and hiatal contraction between healthy subjects and patients with achalasia esophagus.
We performed a prospective study of 10 healthy subjects (controls; 7 male; mean age, 60 ± 15 years; mean body mass index, 25 ± 2) and 12 patients with a diagnosis of achalasia (7 male; mean age, 63 ± 13 years; mean body mass index, 26 ± 1), enrolled at a gastroenterology clinic. Participants underwent 3D high-resolution manometry (3DHRM) with a catheter equipped with 96 transducers (for the EGJ pressure recording). A 0.5-mm metal ball was taped close to the transducer number 1 of the 3DHRM catheter. EGJ pressure was recorded at end-expiration (LES pressure) and at the peak of forced inspiration (hiatal contraction). Computed tomography (CT) scans were performed to localize the circumferential location of the metal ball on the catheter. Esophagus, LES, stomach, right and left crus of the diaphragm, and spine were segmented in each CT scan slice images to construct the 3D morphology of the region.
The metal ball was located at the 7 o’clock position in all controls. The circumferential orientation of metal ball was displaced 45 to 90 degrees in patients with achalasia compared with controls. The 3D-pressure profile of the EGJ at end-expiration and forced inspiration revealed marked differences between the groups. The LES turns to the left as it entered from the chest into the abdomen, forming an angle between the spine and LES. The spine-LES angle was smaller in patients with achalasia (104°) compared with controls (124°). Five of the 10 subjects with achalasia had physical breaks in the left crus of the diaphragm
Besides LES, the 3D pressure profile of the EGJ can indicate anatomic and functional abnormalities of the crural diaphragm muscle in patients with achalasia esophagus. Further studies are needed to define the nature of hiatal and crural diaphragm dysfunction in patients with achalasia of the esophagus.
Imaging Findings of Vaping-Associated Lung Injury Henry, Travis S; Kligerman, Seth J; Raptis, Constantine A ...
American journal of roentgenology (1976),
03/2020, Letnik:
214, Številka:
3
Journal Article
Recenzirano
To listen to the podcast associated with this article, please select one of the following: iTunes or Google Play.
E-cigarettes are devices that aerosolize nicotine- or cannabis-based concentrates ...mixed with other solvents and have been marketed as an alternative to cigarettes. E-cigarette use, or vaping, is increasingly popular but has not been proven to be an innocuous substitute for traditional smoking. Several patterns of vaping-associated inhalational lung injuries have been reported in the past few years. This article reviews many of the imaging patterns that have been encountered in association with e-cigarette use.
E-cigarette use is associated with a range of lung injury patterns that have only recently been recognized as use of these products continues to rise. When the radiologist sees one of these patterns of lung injury, it is important to raise the possibility of vaping-induced lung injury because cessation of vaping is an important step in treatment.
To investigate the performance of Dual-AI Deep Learning Platform in detecting unreported pulmonary nodules that are 6 mm or greater, comprising computer-vision (CV) algorithm to detect pulmonary ...nodules, with positive results filtered by natural language processing (NLP) analysis of the dictated report.
Retrospective analysis of 5047 chest CT scans and corresponding reports. Cases which were both CV algorithm positive (nodule ≥ 6 mm) and NLP negative (nodule not reported), were outputted for review by 2 chest radiologists.
The CV algorithm detected nodules that are 6 mm or greater in 1830 (36.3%) of 5047 cases. Three hundred fifty-five (19.4%) were unreported by the radiologist, as per NLP algorithm. Expert review determined that 139 (39.2%) of 355 cases were true positives (2.8% of all cases). One hundred thirty (36.7%) of 355 cases were unnecessary alerts-vague language in the report confounded the NLP algorithm. Eighty-six (24.2%) of 355 cases were false positives.
Dual-AI platform detected actionable unreported nodules in 2.8% of chest CT scans, yet minimized intrusion to radiologist's workflow by avoiding alerts for most already-reported nodules.
e-Cigarette or vaping-induced lung injury (EVALI) causes a spectrum of CT lung injury patterns. Relative frequencies and associations with vaping behavior are unknown.
What are the frequencies of ...imaging findings and CT patterns in EVALI and what is the relationship to vaping behavior?
CT scans of 160 subjects with EVALI from 15 institutions were retrospectively reviewed. CT findings and patterns were defined and agreed on via consensus. The parenchymal organizing pneumonia (OP) pattern was defined as regional or diffuse ground-glass opacity (GGO) ± consolidation without centrilobular nodules (CNs). An airway-centered OP pattern was defined as diffuse CNs with little or no GGO, whereas a mixed OP pattern was a combination of the two. Other patterns included diffuse alveolar damage (DAD), acute eosinophilic-like pneumonia, and pulmonary hemorrhage. Cases were classified as atypical if they did not fit into a pattern. Imaging findings, pattern frequencies, and injury severity were correlated with substance vaped (marijuana derives tetrahydrocannabinol THC only, nicotine derivates only, and both), vaping frequency, regional geography, and state recreational THC legality. One-way analysis of variance, χ
test, and multivariable analyses were used for statistical analysis.
A total of 160 patients (79.4% men) with a mean age of 28.2 years (range, 15-68 years) with EVALI underwent CT scan. Seventy-seven (48.1%), 15 (9.4%), and 68 (42.5%) patients admitted to vaping THC, nicotine, or both, respectively. Common findings included diffuse or lower lobe GGO with subpleural (78.1%), lobular (59.4%), or peribronchovascular (PBV) sparing (40%). Septal thickening (50.6%), lymphadenopathy (63.1%), and CNs (36.3%) were common. PBV sparing was associated with younger age (P = .02). Of 160 subjects, 156 (97.5%) had one of six defined patterns. Parenchymal, airway-centered, and mixed OP patterns were seen in 89 (55.6%), 14 (8.8%), and 32 (20%) patients, respectively. Acute eosinophilic-like pneumonia (six of 160, 3.8%), DAD (nine of 160, 5.6%), pulmonary hemorrhage (six of 160, 3.8%), and atypical (four of 160, 2.5%) patterns were less common. Increased vaping frequency was associated with more severe injury (P = .008). Multivariable analysis showed a negative association between vaping for > 6 months and DAD pattern (P = .03). Two subjects (1.25%) with DAD pattern died. There was no relation between pattern and injury severity, geographic location, and state legality of recreational use of THC.
EVALI typically causes an OP pattern but exists on a spectrum of acute lung injury. Vaping habits do not correlate with CT patterns except for negative correlation between vaping > 6 months and DAD pattern. PBV sparing, not previously described in acute lung injury, is a common finding.