This paper presents an optimization method to design a solar water heating (SWH) system based on life cycle cost (LCC). A genetic algorithm is employed to optimize its configuration and sizing as the ...optimization technique. To ensure that the optimal solution obtained from the proposed method is a practical design, three constraint conditions, including the energy balance, solar fraction, and available space to install solar collectors, have been set. In addition, the real devices available in the marketplace are considered in the optimization process that searches for optimal configuration and sizing, which is represented by the type and number of each component. By using the proposed method, a SWH system in an office building, South Korea has been designed and optimized. It is observed that a low solar fraction does not always present a decrease in the LCC. A trade-off between the equipment cost and the energy cost results in an optimal design of the SWH system that yields the minimum LCC.
Many studies have sought to overcome the two main limitations of the average method of ISO 9869-1—its long test duration and low accuracy. These studies reported that the reliability of the results ...is dependent on the temperature differences. This consensus was based on the results of studies that measured a few cases with specific temperature differences, and the convergence criteria utilized for the representative thermal transmittance (U-value) were rarely examined. This study analyzed the influence of the average temperature difference and test duration on the convergence characteristics and accuracy of U-value estimation using the average method. Data from a north-facing exterior wall with a theoretical U-value of 0.145 W/m2·K were measured between June 2022 and May 2023. The influences of different measurement conditions were analyzed for cases divided based on four measurement periods and 11 average air temperature differences. The findings show that an accurate U-value can be obtained from 7 days’ worth of measurement data with an average temperature difference of 10 °C or higher and that the improvement in accuracy is minimal under stricter conditions. To achieve a convergence probability of over 90% for temperature differences of 10 °C or greater, the second and third criteria required measurement periods of 7 and 15 days respectively.
Accurate and rapid in situ measurements of the thermal resistance (R-value) of building envelopes are necessary for assessing planned performance and identifying appropriate retrofitting strategies. ...Although there are several approaches for in situ R-value estimation, the average method of ISO 9869-1 based on the heat flow meter method is the most widely used. However, discrepancies between theoretical and in situ R-values are frequently reported in many studies that employ this method. This study aimed to investigate the cause of this discrepancy in estimating in situ R-values of highly insulated building walls using the average method of ISO 9869-1 by conducting long-term experiments. This study was made possible due to a specially constructed test wall wherein more sensors were installed than are required by the ISO 9869-1 standard. The findings showed that discrepancies between heat fluxes on the internal surface and heat passing through the wall is the main cause of the error in in situ R-value estimation. Measurement results from winter showed that deviation from the theoretical R-value was 9.12% for the average method and 0.6% for the extended average method, determined by additionally using the temperature and heat flux inside the wall.
In the last few decades, an average method which is regulated by ISO 9869-1 has been used to evaluate the in situ thermal transmittance (U-value) and thermal resistance (R-value) of building ...envelopes obtained from onsite measurements and to verify the validity of newly proposed methods. Nevertheless, only a few studies have investigated the test duration required to obtain reliable results using this method and the convergence characteristics of the results. This study aims to evaluate the convergence characteristics of the in situ values analyzed using the average method. The criteria for determining convergence (i.e., end of the test) using the average method are very strict, mainly because of the third condition, which compares the deviation of two values derived from the first and last periods of the same duration. To shorten the test duration, environmental variables should be kept constant throughout the test or an appropriate period should be selected. The convergence of the in situ U-value and R-value is affected more by the length of the test duration than by the temperature difference if the test environment meets literature-recommended conditions. Furthermore, there is no difference between the use of the U-value and R-value in determining the end of the test.
In this paper, we propose a non-iterative transceiver design based on interference alignment (IA) for MIMO interfering broadcast channels with arbitrary number of cells and users per cell. We ...consider the case where a base station has more antennas than a user, which is a typical scenario of downlink transmission in the cellular network. By aligning the interference from other cells efficiently, we show that the proposed transceiver design can achieve the degrees of freedom (DOF) of d per user, i.e., total DOF of Σ i=1 C K i d, where C is the number of cells, K i is the number of users for the i-th cell, and d is the number of streams per user. Accordingly, we investigate conditions for the antenna configuration to attain the total DOF of Σ i=1 C K i d. We also analyze the computational complexity and achievable DOF of the proposed transceiver design. Finally, simulation results are provided to assess the sum-rate performance and achievable DOF of the proposed transceiver design, which validates the advantage of our design over existing schemes.
Spinal surgery performed entirely with minimally invasive surgery is referred to as circumferential MIS (cMIS). However, cMIS still has a limited sagittal correction capability for adult spinal ...deformity (ASD) with a marked sagittal deformity. We investigated the effectiveness of cMIS using oblique lateral interbody fusion (OLIF) and percutaneous posterior spine fixation in correcting marked sagittal deformity.
This study retrospectively evaluated 23 patients with ASD with marked sagittal deformity who underwent cMIS using OLIF without osteotomy and were followed-up for at least 24 months (whole group). The whole group was divided into the following two groups according to the type of interbody fusion at L5-S1: the OLIF51 group (n = 13) underwent OLIF at L1-L5 and L5-S1 and the TLIF51 group (n = 10) underwent OLIF at L1-L5 and transforaminal lumbar interbody fusion (TLIF) at L5-S1.
Sagittal vertebral axis (SVA; 125.7 vs. 29.5 mm, p < 0.001), lumbar lordosis (LL; 18.2° vs. 51.7°, p < 0.001), and pelvic incidence-LL mismatch (PI-LL, 35.5° vs. 5.3°) significantly improved postoperatively in the whole group. The OLIF51 group showed significantly higher postoperative LL than the TLIF51 group (55.5° vs. 46.9°, p < 0.001). OLIF yielded a significantly greater disc angle at L5-S1 than did TLIF (18.4° vs. 6.9°, p < 0.001). Proximal junctional kyphosis occurred significantly earlier in the OLIF51 group than in the TLIF51 group (8.6 vs. 26.3 months, p < 0.001).
Successful sagittal correction in ASD patients with marked sagittal deformity was achieved with cMIS using OLIF. OLIF at L5-S1 showed a synergistic effect in sagittal deformity correction by cMIS.
To maximize the energy performance and economic benefits of solar water heating (SWH) systems, the installation and operation-related design variables as well as those related to capacity must be ...optimized. This paper presents a novel design method for simultaneously optimizing the various design variables of an indirect forced-circulation SWH system that is based on the life cycle cost and uses a genetic algorithm. The effectiveness of the proposed method is assessed by evaluating the long-term performance corresponding to four cases, which are optimized using different annual solar fractions and sets of the design variables. When the installation and operation-related design variables were taken into consideration, it resulted in an efficient and economic design and an extra cost reduction of 3.2%-6.1% over when only the capacity-related design variables were considered. In addition, the results of parametric studies show that the slope and mass flow rate of the collector have a significant impact on the energy and economic performances of SWH systems. In contrast, the mass flow rate in the secondary circuit and the differences in the temperatures of the upper and lower dead bands of the differential controller have a smaller impact.
There are several methods to obtain the in situ thermal transmittance value (U-value) of building envelopes from on-site data, including the three approaches of the progressive average method, ...average method considering the thermal storage effect, and dynamic method for deriving the U-value from heat flowmeter (HFM) measurements and the four methods with different formulas to analyze infrared thermography (IRT) measurement data. Since each of these methods considers different parameters and the non-steady characteristics of the heat transfer in building walls in their own way, discrepancies may occur among the obtained results. This study evaluates and compares the in situ U-values by using various methods of analyzing HFM and IRT measurement data. Further, by investigating buildings with similar materials and identical stratigraphies, but with different construction years, we analyze the discrepancy between the designed and measured values caused by material deterioration and evaluate the errors according to the analysis method. The percentage deviation between the U-values obtained by the three methods from the HFM data is found to be satisfactory, being within 10%. When compared with the results of the progressive average method, the deviations for the four different IRT-measurement-based methods vary greatly, being in the range of 6–43%.
In this study, the multi-objective optimization of an indirect forced-circulation solar water heating (SWH) system was performed to obtain the optimal configuration that minimized the life cycle cost ...(LCC) and maximized the life cycle net energy saving (LCES). An elitist non-dominated sorting genetic algorithm (NSGA-II) was employed to obtain the Pareto optimal solutions of the multi-objective optimization. To incorporate the characteristics of practical SWH systems, operation-related decision variables as well as capacity-related decision variables were included. The proposed method was used to conduct a case study wherein the optimal configuration of the SWH system of an office building was determined. The case study results showed that the energy cost decreases linearly and the equipment cost increases more significantly as the LCES increases. However, the results also showed that it is difficult to identify the best solution among the Pareto optimal solutions using only the correlation between the corresponding objective function values. Furthermore, regression analysis showed that the energy and economic performances of the Pareto optimal solutions are significantly influenced by the ratio of the storage tank volume to the collector area (RVA). Therefore, it is necessary to simultaneously consider the trade-off and the effect of the RVA on the Pareto optimal solutions while selecting the best solution from among the optimal solutions.
In the context of remodeling old buildings, enhancing insulation performance in the exterior skin necessitates an accurate assessment of a wall’s thermal performance. The conventional method for ...determining the thermal transmittance (U-value) of a wall is the heat flow meter (HFM) as outlined in the ISO 9869-1. However, this measurement is susceptible to errors influenced by indoor and outdoor environmental conditions and the wall’s material composition. This study evaluates the U-value of an internally insulated wall, specifically constructed for this purpose, utilizing both the average and dynamic methodologies of an HFM. Furthermore, it introduces a novel estimation method: the extended average method (EXAM). The effectiveness of this proposed method is ascertained by comparing the accuracy and convergence of the U-value estimations with those derived from existing methodologies. Additionally, the study explores the limitations of the HFM by analyzing the heat flow traversing the interior of a wall. The findings revealed that the EXAM method enhanced the precision of U-value estimation in all scenarios. Particularly, in walls with superior insulation, the HFM tended to underestimate the heat flow observed indoors, leading to negative errors. The EXAM method, incorporating considerations of both insulation and structural materials, offers an accurate in situ measurement of the U-value relative to the HFM.