The purpose of our study was to identify and characterize the 100 most-cited articles in neuroimaging. Based on the database of Journal Citation Reports, we selected 669 journals that were considered ...as potential outlets for neuroimaging articles. The Web of Science search tools were used to identify the 100 most-cited articles relevant to neuroimaging within the selected journals. The following information was recorded for each article: publication year, journal, category and impact factor of journal, number of citations, number of annual citations, authorship, department, institution, country, article type, imaging technique used, and topic. The 100 most-cited articles in neuroimaging were published between 1980 and 2012, with 1995–2004 producing 69 articles. Citations ranged from 4384 to 673 and annual citations ranged from 313.1 to 24.9. The majority of articles were published in radiology/imaging journals (n=75), originated in the United States (n=58), were original articles (n=63), used MRI as imaging modality (n=85), and dealt with imaging technique (n=45). The Oxford Centre for Functional Magnetic Resonance Imaging of the Brain at John Radcliffe Hospital (n=10) was the leading institutions and Karl J. Friston (n=11) was the most prolific author. Our study presents a detailed list and an analysis of the 100 most-cited articles in the field of neuroimaging, which provides an insight into historical developments and allows for recognition of the important advances in this field.
•We present a detailed list of the 100 most-cited neuroimaging articles.•MR imaging was used in 85% of the most-cited articles.•New imaging technique or technology was the most highly cited topic with 45% of the top 100 papers.
Objective of this study was to evaluate the effectiveness of the iterative reconstruction of high-pitch dual-source chest CT (IR-HP-CT) scanned with low radiation exposure compared with low dose ...chest CT (LDCT).
This study was approved by the institutional review board. Thirty healthy adult volunteers (mean age 44 years) were enrolled in this study. All volunteers underwent both IR-HP-CT and LDCT. IR-HP-CT was scanned with 120 kVp tube voltage, 30 mAs tube current and pitch 3.2 and reconstructed with sinogram affirmed iterative reconstruction. LDCT was scanned with 120 kVp tube voltage, 40 mAs tube current and pitch 0.8 and reconstructed with B50 filtered back projection. Image noise, and signal to noise ratio (SNR) of the infraspinatus muscle, subcutaneous fat and lung parenchyma were calculated. Cardiac motion artifact, overall image quality and artifacts was rated by two blinded readers using 4-point scale. The dose-length product (DLP) (mGy∙cm) were obtained from each CT dosimetry table. Scan length was calculated from the DLP results. The DLP parameter was a metric of radiation output, not of patient dose. Size-specific dose estimation (SSDE, mGy) was calculated using the sum of the anteroposterior and lateral dimensions and effective radiation dose (ED, mSv) were calculated using CT dosimetry index.
Approximately, mean 40% of SSDE (2.1 ± 0.2 mGy vs. 3.5 ± 0.3 mGy) and 34% of ED (1.0 ± 0.1 mSv vs. 1.5 ± 0.1 mSv) was reduced in IR-HP-CT compared to LDCT (P < 0.0001). Image noise was reduced in the IR-HP-CT (16.8 ± 2.8 vs. 19.8 ± 3.4, P = 0.0001). SNR of lung and aorta of IR-HP-CT showed better results compared with that of LDCT (22.2 ± 5.9 vs. 33.0 ± 7.8, 1.9 ± 0.4 vs 1.1 ± 0.3, P < 0.0001). The score of cardiac pulsation artifacts were significantly reduced on IR-HP-CT (3.8 ± 0.4, 95% confidence interval, 3.7‒4.0) compared with LDCT (1.6 ± 0.6, 95% confidence interval, 1.3‒1.8) (P < 0.0001). SNR of muscle and fat, beam hardening artifact and overall subjective image quality of the mediastinum, lung and chest wall were comparable on both scans (P ≥ 0.05).
IR-HP-CT with 120 kVp and 30 mAs tube setting in addition to an iterative reconstruction reduced cardiac motion artifact and radiation exposure while representing similar image quality compared with LDCT.
Acute ileal diverticulitis is a rare disease mimicking acute appendicitis. Inaccurate diagnosis with a low prevalence and nonspecific symptoms leads to delayed or improper management.
This ...retrospective study aimed to investigate the characteristic sonographic (US) and computed tomography (CT) findings with clinical features in seventeen patients with acute ileal diverticulitis diagnosed between March 2002 and August 2017.
The most common symptom was abdominal pain (82.3%, 14/17) localized to the right lower quadrant (RLQ) in 14 patients. The characteristic CT findings of acute ileal diverticulitis were ileal wall thickening (100%, 17/17), identification of inflamed diverticulum at the mesenteric side (94.1%, 16/17), and surrounding mesenteric fat infiltration (100%, 17/17). The typical US findings were outpouching diverticular sac connecting to the ileum (100%, 17/17), peridiverticular inflamed fat (100%, 17/17), ileal wall thickening with preserved layering pattern (94.1%, 16/17), and increased color flow to the diverticulum and surrounding inflamed fat on color Doppler imaging (100%, 17/17). The perforation group had a significantly longer hospital stay than non-perforation group (
= 0.002). In conclusion, acute ileal diverticulitis has characteristic CT and US findings that allow radiologists to accurately diagnose the disease.
Coxsackievirus A16 (CA16), which primarily causes hand, foot, and mouth disease (HFMD), is associated with complications, such as encephalitis, acute flaccid paralysis, myocarditis, pericarditis, and ...shock. However, no case of pancreatitis associated with CA16 has been reported in children. We report a case of CA16-associated acute pancreatitis in a 3-year-old girl with HFMD. She was admitted because of poor oral intake and high fever for 1 day. Maculopapular rashes on both hands and feet and multiple vesicles on the soft palate were observed on physical examination. She was treated conservatively with intravenous fluids. On the fourth hospital day, she had severe abdominal pain and vomiting. The serum levels of amylase and lipase were remarkably elevated (amylase, 1,902 IU/L; reference range, 28-100 IU/L; lipase, >1,500 IU/L; reference range, 13-60 IU/L), and ultrasonography showed diffuse swelling of the pancreas with a small amount of ascites. The real-time reverse transcription polymerase chain reaction result from a stool sample was positive for CA16. CA16 can cause acute pancreatitis, and should be considered in the differential diagnosis of abdominal pain in children with HFMD.
This retrospective study aimed to determine the number of times the ultrasound-guided attenuation parameter (UGAP) should be measured during the evaluation of hepatic steatosis.
Patients with ...suspected nonalcoholic fatty liver disease who underwent two UGAP repetition protocols (six-repetition UGAP_6 and 12-repetition UGAP_12) and measurement of the controlled attenuation parameter (CAP) using transient elastography between October 2020 and June 2021 were enrolled. The mean attenuation coefficient (AC), interquartile range (IQR)/median, and coefficient of variance (CV) of the two repetition protocols were compared using the paired t test. Moreover, the diagnostic performances of UGAP_6 and UGAP_12 were compared using the area under the receiver operating characteristic (AUROC) curve, considering the CAP value as a reference standard.
The study included 160 patients (100 men; mean age, 50.9 years). There were no significant differences between UGAP_6 and UGAP_12 (0.731±0.116 dB/cm/MHz vs. 0.734±0.113 dB/cm/MHz, P=0.156) and mean CV (7.6±0.3% vs. 8.0±0.3%, P=0.062). However, the mean IQR/median of UGAP_6 was significantly lower than that of UGAP_12 (8.9%±6.0% vs. 9.8%±5.2%, P=0.012). In diagnosing the hepatic steatosis stage, UGAP_6 and UGAP_12 yielded comparable AUROCs (≥S1, 0.908 vs. 0.897, P=0.466; ≥S2, 0.883 vs. 0.897, P=0.126; S3, 0.832 vs. 0.834, P=0.799).
UGAP had high diagnostic performance in diagnosing hepatic steatosis, regardless of the number of repetitions (six repetitions vs. 12 repetitions), with maintained reliability. Therefore, six UGAP measurements seem sufficient for evaluating hepatic steatosis using UGAP.
Evaluation of hepatic fibrosis is essential to prevent liver-related morbidity and mortality. Although various types of ultrasound shear wave elastography (SWE) have been used and validated, there ...are limited studies on the relatively newer technique, two-dimensional SWE (2D-SWE). Therefore, this study aimed to compare the diagnostic performances of 2D-SWE and point SWE (p-SWE) for evaluating liver fibrosis using histology as the reference standard. To measure liver stiffness (LS) values, 87 patients underwent 2D-SWE and p-SWE using the same machine. Technical failures and unreliable measurements were also evaluated. The diagnostic performances of 2D-SWE and p-SWE were compared using area under the receiver operating characteristic (AUROC) curve analysis. No technical failures were observed in either method; however, unreliable measurements were less frequent in 2D-SWE (1/87 1.1%) than in p-SWE (8/87 9.2%) (
< 0.001). The AUROC of the LS values of 2D-SWE were significantly higher than those of p-SWE for diagnosing significant fibrosis (0.965 vs. 0.872,
= 0.022) and cirrhosis (0.994 vs. 0.886,
= 0.042). In conclusion, 2D-SWE is more reliable and accurate than p-SWE for diagnosing hepatic fibrosis.
The number of citations that an article has received can be used to evaluate its impact on the scientific community. This study aimed to identify the 100 most cited articles in the field of ...neurointervention and to analyze their characteristics.
We selected the 669 journals that were considered potentially to publish neurointervention articles based on the database of Journal Citation Reports. Using the Web of Science citation search tool, we identified the 100 most cited articles relevant to neurointervention within the selected journals. Each article was evaluated for several characteristics including publication year, journal, journal category, impact factor, number of citations, number of citations per year, authorship, department, institution, country, type of article, and topic.
The number of citations for the top 100 articles ranged from 1912 to 170 (mean 363.4) and citations per year ranged from 271.0 to 4.1 (mean 40.0). The majority of articles were published in clinical neurology journals (63%), were published in 2000-2009 (39%), originated in the USA (45%), were original articles (95%), and dealt with endovascular treatment of cerebral aneurysm (42%). The Department of Radiology, University of California School of Medicine (n=12) was the leading institution and Viñuela F (n=11) was the most prolific author.
Our study presents a detailed list and analysis of the 100 most cited articles in the field of neurointervention and provides a historical perspective on the scientific progress in this field.
Ultrasonography is a useful technique to detect soft tissue changes of rheumatoid arthritisnot only synovitis, but also tenosynovitis, bursitis, and enthesitis-even at a subclinical stage. However, ...radiologists tend to focus on synovitis in daily practice, and unusual peri- or extraarticular manifestations of rheumatoid arthritis are difficult to detect at the initial presentation. This pictorial essay describes a broad spectrum of ultrasonographic findings in tendons, bursae, ligaments, subcutaneous tissues, bones, and nerves to assist in the accurate diagnosis of rheumatoid arthritis.
This study aimed to assess the technical performance of ElastQ Imaging compared with ElastPQ and to investigate the correlation between liver stiffness (LS) values obtained using these two ...techniques.
This retrospective study included 249 patients who underwent LS measurements using both ElastPQ and ElastQ Imaging equipped on the same machine. The applicability, repeatability (coefficient of variation CV), acquisition time, and LS values were compared using the chi-square or Wilcoxon signed-rank tests. In the development group, the correlation between the LS values obtained by the two techniques was assessed with Spearman correlation coefficients and linear regression analysis. In the validation group, the agreement between the estimated and real LS values was evaluated using a Bland-Altman plot.
ElastQ Imaging had higher applicability (94.0% vs. 78.3%, P<0.001) and higher repeatability, with a lower median CV (0.127 vs. 0.164, P<0.001) than did ElastPQ. The median acquisition time of ElastQ Imaging was significantly shorter than that of ElastPQ (45.5 seconds vs. 96.5 seconds, P<0.001). The median LS value obtained using ElastQ Imaging was significantly higher than that obtained using ElastPQ (5.60 kPa vs. 5.23 kPa, P<0.001). The LS values between the two techniques exhibited a strong positive correlation (r=0.851, P<0.001) in the development group. The mean difference and 95% limits of agreement were 0.0 kPa (-3.9 to 3.9 kPa) in the validation group.
ElastQ Imaging may be more reliable and faster than ElastPQ, with strongly correlated LS measurements.