We report an amplitude analysis and branching fraction measurement of D+s → K+K−π+ decay using a data sample of 3.19 fb−1 recorded with BESIII detector at a center-of-mass energy of 4.178 GeV. We ...perform a model-independent partial wave analysis in the low K+K− mass region to determine the K+K− S-wave line shape, followed by an amplitude analysis of our very pure high-statistics sample. With the detection efficiency based on the amplitude analysis results, the absolute branching fraction is measured to be B(D+s → K+K− π+) = (5.47 ± 0.0 8stat ± 0.13sys)%.
Recently, the LHAASO Collaboration published the detection of 12 ultrahigh-energy γ-ray sources above 100 TeV, with the highest energy photon reaching 1.4 PeV. The first detection of PeV γ rays from ...astrophysical sources may provide a very sensitive probe of the effect of the Lorentz invariance violation (LIV), which results in decay of high-energy γ rays in the superluminal scenario and hence a sharp cutoff of the energy spectrum. Two highest energy sources are studied in this work. No signature of the existence of the LIV is found in their energy spectra, and the lower limits on the LIV energy scale are derived. Our results show that the first-order LIV energy scale should be higher than about 10^{5} times the Planck scale M_{Pl} and that the second-order LIV scale is >10^{-3}M_{Pl}. Both limits improve by at least one order of magnitude the previous results.
The kilometer square array (KM2A) of the large high altitude air shower observatory (LHAASO) aims at surveying the northern γ-ray sky at energies above 10 TeV with unprecedented sensitivity. γ-ray ...observations have long been one of the most powerful tools for dark matter searches, as, e.g., high-energy γ rays could be produced by the decays of heavy dark matter particles. In this Letter, we present the first dark matter analysis with LHAASO-KM2A, using the first 340 days of data from 1/2-KM2A and 230 days of data from 3/4-KM2A. Several regions of interest are used to search for a signal and account for the residual cosmic-ray background after γ/hadron separation. We find no excess of dark matter signals, and thus place some of the strongest γ-ray constraints on the lifetime of heavy dark matter particles with mass between 10^{5} and 10^{9} GeV. Our results with LHAASO are robust, and have important implications for dark matter interpretations of the diffuse astrophysical high-energy neutrino emission.
Gravitational‐wave high‐energy Electromagnetic Counterpart All‐sky Monitor (GECAM) is a space‐borne instrument dedicated to monitoring high‐energy transients, including Terrestrial Gamma‐ray Flashes ...(TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB‐like events are identified during an effective observation time of ∼9 months. We show that, with gamma‐ray and charged particle detectors, GECAM can effectively identify and distinguish TGFs and TEBs, and measure their temporal and spectral properties in detail. A very high TGF‐lightning association rate of ∼80% is obtained between GECAM and GLD360 in east Asia region.
Plain Language Summary
Terrestrial gamma‐ray flashes (TGFs) and Terrestrial Electron Beams (TEBs) represent the most energetic radioactive phenomena in the atmosphere of the Earth. They reflect a natural particle accelerator that can boost electrons up to at least several tens of mega electron volts and produce gamma‐ray radiation. With novel detection technologies, Gravitational‐wave high‐energy Electromagnetic Counterpart All‐sky Monitor (GECAM) is a new powerful instrument to observe TGFs and TEBs, as well as study their properties. For example, it is difficult for most space‐borne high‐energy instruments to distinguish between TGFs and TEBs. However, we show here that, with the joint observation of gamma‐ray and charged particle detectors, GECAM can effectively identify TGFs and TEBs. GECAM can also reveal their fine features in the light curves and spectra.
Key Points
During 9‐month observation, Gravitational‐wave high‐energy Electromagnetic Counterpart All‐sky Monitor (GECAM) has detected 147 bright Terrestrial Gamma‐ray Flashes (TGFs), 2 typical Terrestrial Electron Beams (TEBs), and 2 special TEB‐like events
With novel detector design, GECAM can effectively classify TGFs and TEBs, and reveal their fine temporal features
We obtained a very high TGF‐lightning association rate (∼80%) between GECAM and GLD360 in east Asia region
We report a measurement of electron antineutrino oscillation from the Daya Bay Reactor Neutrino Experiment with nearly 4 million reactor νover ¯_{e} inverse β decay candidates observed over 1958 days ...of data collection. The installation of a flash analog-to-digital converter readout system and a special calibration campaign using different source enclosures reduce uncertainties in the absolute energy calibration to less than 0.5% for visible energies larger than 2 MeV. The uncertainty in the cosmogenic ^{9}Li and ^{8}He background is reduced from 45% to 30% in the near detectors. A detailed investigation of the spent nuclear fuel history improves its uncertainty from 100% to 30%. Analysis of the relative νover ¯_{e} rates and energy spectra among detectors yields sin^{2}2θ_{13}=0.0856±0.0029 and Δm_{32}^{2}=(2.471_{-0.070}^{+0.068})×10^{-3} eV^{2} assuming the normal hierarchy, and Δm_{32}^{2}=-(2.575_{-0.070}^{+0.068})×10^{-3} eV^{2} assuming the inverted hierarchy.
Measurements of 21 cm Epoch of Reionization (EoR) structure are subject to systematics originating from both the analysis and the observation conditions. Using 2013 data from the Murchison Widefield ...Array (MWA), we show the importance of mitigating both sources of contamination. A direct comparison between results from Beardsley et al. and our updated analysis demonstrates new precision techniques, lowering analysis systematics by a factor of 2.8 in power. We then further lower systematics by excising observations contaminated by ultra-faint RFI, reducing by an additional factor of 3.8 in power for the zenith pointing. With this enhanced analysis precision and newly developed RFI mitigation, we calculate a noise-dominated upper limit on the EoR structure of Δ2 ≤ 3.9 × 103 mK2 at k = 0.20 h Mpc−1 and z = 7 using 21 hr of data, improving previous MWA limits by almost an order of magnitude.
Although flow diverters have been reported with favorable clinical and angiographic outcomes in various literatures, randomized trials determining their true effectiveness and safety are still in ...lack. The Parent Artery Reconstruction for Large or Giant Cerebral Aneurysms Using the Tubridge Flow Diverter (PARAT) trial was designed to evaluate the safety and efficacy of the Tubridge flow diverter in the treatment of large or giant aneurysms in comparison with Enterprise stent-assisted coiling.
This prospective, multicenter, randomized trial was conducted at 12 hospitals throughout China. Enrolled adults with unruptured large/giant intracranial aneurysms were randomly assigned (1:1) to receive either Enterprise stent-assisted coiling or Tubridge flow diverter implantation. The primary end point was complete occlusion at 6-month follow-up, while secondary end points included technical success, mortality, target vessel-related stroke, aneurysm bleeding, in-stent stenosis, parent artery occlusion, and the frequency of all adverse events.
Among 185 enrolled subjects, 41 withdrew before procedure initiation. Overall, 82 subjects underwent Tubridge implantation, and 62 subjects were primarily treated with stent-assisted coiling. The results of 6-month follow-up imaging included complete occlusion rates of 75.34% versus 24.53% for the Tubridge and stent-assisted coiling groups, respectively, with a calculated common odds ratio of 9.4 (95% confidence interval, 4.14-21.38;
< .001). There was a higher, nonsignificant frequency of complications for Tubridge subjects. Multivariate analysis showed a decreased stroke rate at the primary investigational site, with a marginal
value (
= .051).
This trial showed an obviously higher rate of large and giant aneurysm obliteration with the Tubridge FD over Enterprise stent-assisted coiling. However, this higher obliteration rate came at the cost of a nonsignificantly higher rate of complications. Investigational site comparisons suggested that a learning curve for flow-diverter implantation should be recognized and factored into trial designs.