Ablation of hepatocellular carcinoma Kim, Young-sun, M.D; Lim, Hyo Keun, M.D; Rhim, Hyunchul, M.D ...
Baillière's best practice & research. Clinical gastroenterology,
10/2014, Letnik:
28, Številka:
5
Journal Article
Recenzirano
Abstract Radiofrequency ablation (RFA) has gained a wide acceptance as a first-line therapeutic option for small hepatocellular carcinoma (HCC). For very early-stage HCC, despite a higher rate of ...local tumour progression, RFA is considered as a viable alternative to surgical resection owing to its comparable long-term survival, reduced morbidity, and greater preservation of hepatic parenchyma. For HCCs larger than 2 cm, RFA can contribute to near-curative therapy when combined with chemoembolization. RFA can be used as part of a multimodal treatment strategy for more advanced or recurrent cases, and could be a useful bridging therapy for patients who are waiting for liver transplantation. However, the use of RFA is still limited in treating large tumours and some tumours in high-risk locations. To overcome its current limitations, other ablation techniques are being developed and it is important to validate the role of other techniques for enhancing performance of ablation therapy for HCC.
To evaluate the performance of dual internally cooled wet tip (ICWT) radiofrequency electrodes in comparison to dual internally cooled tip (ICT) electrodes.
Twenty ablation zones were created for ...each type of electrodes. Planned procedure time was 6 min. Diameters of the ablation zone along the x-, y-, and z-axes (Dx, Dy, and Dz), ablation zone sphericity, quantitative sphericity measurement, and ablation volume were measured and compared between the two electrode types. Circularity of the ablation zone on the surface with x- and z- axes (zx plane) and amount of energy applied were also compared.
Dx and Dz were significantly longer with ICWT than those with ICT (Dx: 3.0 vs. 2.8 cm, p = .018; and Dz: 2.7 vs. 2.3 cm, p < .001, respectively). Dy was not significantly different (3.0 vs. 2.9 cm, p = .220). Moreover, 85% (17/20) and 30% (6/20) of ablation zones from ICWT and ICT were spherical (p = .001), respectively. Quantitative measurement showed that ICWT was more spherical compared to ICT (0.962 vs. 0.881, p = .001). The ablation volume was also significantly higher with ICWT (11.55 vs. 9.45 cm3, p = .003). The ablation zone on the zx plane was more circular with ICWT (0.907 vs. 0.883, p = .028). The amount of energy applied was significantly bigger with ICWT (18508 vs. 16998 WS, p = .003).
Dual ICWT electrodes were better able to create more spherical and larger ablation zones than dual ICT electrodes.
We reviewed all studies assessing the health-related quality of life (HRQoL) in patients with hepatocellular carcinoma (HCC) between 2009 and 2018 (n = 45). Most studies assessed HRQoL as an outcome, ...and evaluated or compared the HRQoL of HCC patients depending on the type of treatment or stage of disease. HCC patients had a worse HRQoL than the general population, including in those with early-stage HCC. Patients commonly experienced pain, fatigue, sleep disturbance, distress, and lack of appetite, and these symptoms remained problematic even a few years after treatment. TNM classification of malignant tumors stage, tumor stage, presence of cirrhosis, being Asian, being female, living alone, or being unemployed were associated with a poor HRQoL. While recent studies have included a more diverse patient population, various topics, and different study designs, there were limited studies on supportive interventions. Given the increase in HCC cases and HCC survivors, addressing the HRQoL of HCC patients requires more attention.
To evaluate initial clinical outcomes of volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) ablation by using a one-layer strategy to treat large (>10 cm in diameter) ...uterine fibroids, with investigation of the correlation between effectiveness of the one-layer strategy and dynamic contrast material-enhanced (DCE) MR parameters.
Institutional review board approval and informed consent were obtained. Twenty-seven women (mean age, 44.5 years) with 27 large uterine fibroids (mean diameter, 11.3 cm ± 1.4 standard deviation range, 10.1-16.0 cm; fibroid volume, 502.5 mL ± 214.3 range, 253.8-1184.0 mL) underwent volumetric MR-guided HIFU ablation with a one-layer strategy. (All treatment cells were placed in one coronal plane at a depth of half to anterior two-thirds of the anteroposterior dimension of fibroids.) Treatment time, immediate nonperfused volume (NPV), and effectiveness of a one-layer strategy (ratio of immediate NPV to total volume of treatment cells planned) correlating with baseline DCE MR parameters (volume transfer constant K(trans), fractional extravascular extracellular space, and fractional blood plasma volume Pearson correlation test), complications, 3-month follow-up volumes, and symptom severity score (SSS) changes (paired t test) were assessed retrospectively.
All treatments showed technical success in one session (mean treatment time, 166.2 minutes ± 38.9). NPV was 301.3 mL ± 119.1, which was 64.2% ± 19.9 (<50%, n = 4; ≥ 50%, n = 23) of fibroid volume. Ratio of immediate NPV to total volume of treatment cells (1.79 ± 0.61) negatively correlated with DCE MR imaging K(trans) values (r = -0.426, P = .017). Minor complications occurred in five patients (18.5% thermal injury of abdominal wall, n = 3; 30-day leg numbness, n = 1; cystitis, n = 1). At 3-month follow-up (n = 18), mean SSS had decreased from 37.4 at baseline to 24.0 (P < .001), and volume reduction ratio was 0.64 ± 0.15 (P < .001).
Volumetric MR-guided HIFU ablation with a one-layer strategy is safe and effective for treatment of large uterine fibroids. Effectiveness of this strategy showed a significant negative correlation with K(trans) values at baseline DCE MR imaging.
The influence of surface activated bonding (SAB) on adhesion strength between a metal and ceramic including Al/AlN and Cu/AlN is investigated. Plasma pre-treatments can significantly increase the ...adhesion strength between the metal and ceramic through surface activation, which can enlarge the contact area between metal and ceramic. Bonding pressure is also an important factor to improve the adhesion between metal and ceramic during SAB. Successful bonding between the metal and ceramic via SAB can be attributed to the formation of the interface layer where plastic deformation and rearrangement of metal to the ceramic occurs, which improves the atomic scale interconnection between the metal and ceramic. In this study, the influence of experimental SAB conditions for processing such as plasma power, degree of vacuum and bonding pressure on adhesion strength is investigated. Also, the thermal conduction of metal/ceramic laminates is discussed for its potential application as a heat spreader of LED chips.
This study aimed to evaluate the incidence and severity of biliary complications after treating periductal hepatocellular carcinomas (HCCs) using either cryoablation (CA) or radiofrequency ablation ...(RFA) and assess independent risk factors for biliary complications after treatment.
Between July 2008 and August 2018, 949 patients with treatment-naïve HCCs underwent either RFA or CA in our institution. Of these, patients with multiple HCCs, tumors equal to or larger than 3 cm or smaller than 1 cm, and tumors with non-periductal locations were excluded. Finally, 31 patients and 25 patients were included in the RFA group and the CA group, respectively. The incidence and severity of biliary complications were compared between the RFA and CA groups. The risk factors for biliary complications were assessed using univariable and multivariable logistic regression analyses using the following variables: age, sex, tumor size, Child-Pugh score, tumor location (peripheral duct versus central duct), ablation method (RFA versus CA), the number of applicators, ablation time, and ablation volume.
The incidence and severity of biliary complications were significantly higher in the RFA group than in the CA group (p = 0.007 and p = 0.002, respectively). In univariable and multivariable analyses, the ablation method was an independent risk factor for biliary complications (p = 0.004 and 0.013, respectively).
The incidence and severity of biliary complications after treating HCCs abutting the bile duct are lower in CA than RFA, demonstrating that CA is safer than RFA for ablating small periductal HCCs.
The aim of this study was to evaluate the association of contrast-enhanced ultrasound (CEUS) features using Sonazoid for liver nodules with Liver Imaging Reporting and Data System (LI-RADS) ...categories and to identify the usefulness of Kupffer-phase images.
This retrospective study was conducted in 203 patients at high risk of hepatocellular carcinoma (HCC) who underwent CEUS with Sonazoid from 2013 to 2016. Nodule enhancement in the arterial, portal venous, late, and Kupffer phases; CEUS LI-RADS major features; and Kupffer-phase defects were evaluated. According to the computed tomography/magnetic resonance imaging (CT/MRI) LI-RADS v2018, all nodules were assigned an LR category (n=4/33/99/67 for LR-M/3/4/5) and comparisons across LR categories were made. We defined modified CEUS LI-RADS as using Kupffer-phase defects as an alternative to late and mild washout in CEUS LI-RADS and compared the diagnostic performance for HCC.
On CEUS of 203 nodules, 89.6% of CT/MRI LR-5 and 85.9% of LR-4 nodules showed hyperenhancement in the arterial phase, while 57.6% of LR-3 nodules showed hyperenhancement. Among the CT/MRI LR-5 nodules that showed arterial phase hyperenhancement or isoenhancement, 59.7% showed hypoenhancing changes from the portal venous phase, 23.9% from the late phase, and 13.4% additionally in the Kupffer phase. The modified CEUS LI-RADS showed higher sensitivity than CEUS LI-RADS (83.2% vs. 74.2%, P=0.008) without compromising specificity (63.6% vs. 69.7%, P=0.500).
The Kupffer phase best shows hypoenhancing changes in LR-5 lesions and is expected to improve the sensitivity for HCC in high-risk patients.
High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive ...technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments.
To compare the therapeutic outcomes of laparoscopic hepatic resection (LHR) and laparoscopic radiofrequency ablation (LRFA) for single subcapsular hepatocellular carcinoma (HCC).
We screened 244 ...consecutive patients who had received either LHR or LRFA between January 2014 and December 2016. The feasibility of LRFA in patients who underwent LHR was retrospectively assessed by two interventional radiologists. Finally, 60 LRFA-feasible patients who had received LHR and 29 patients who had received LRFA as the first treatment for a solitary subcapsular HCC between 1 cm and 3 cm were finally included. We compared the therapeutic outcomes, including local tumor progression (LTP), recurrence-free survival (RFS), and overall survival (OS) between the two groups before and after propensity score (PS) matching. Multivariable Cox proportional hazard regression was also used to evaluate the difference in OS and RFS between the two groups for all 89 patients.
PS matching yielded 23 patients in each group. The cumulative LTP and OS rates were not significantly different between the LHR and LRFA groups after PS matching (
= 0.900 and 0.003, respectively). The 5-year LTP rates were 4.6% and 4.4%, respectively, and OS rates were 100% and 90.7%, respectively. The RFS rate was higher in LHR group without statistical significance (
= 0.070), with 5-year rates of 78.3% and 45.3%, respectively. OS was not significantly different between the LHR (reference) and LRFA groups in multivariable analyses, with a hazard ratio (HR) of 1.33 (95% confidence interval, 0.12-1.54) (
= 0.818). RFS was higher in LHR (reference) than in LRFA without statistical significance in multivariable analysis, with an HR of 2.01 (0.87-4.66) (
= 0.102).
There was no significant difference in therapeutic outcomes between LHR and LRFA for single subcapsular HCCs measuring 1-3 cm. The difference in RFS should be further evaluated in a larger study.