Health-relevant microorganisms present in natural surface waters and engineered treatment systems that are exposed to sunlight can be inactivated by a complex set of interacting mechanisms. The net ...impact of sunlight depends on the solar spectral irradiance, the susceptibility of the specific microorganism to each mechanism, and the water quality; inactivation rates can vary by orders of magnitude depending on the organism and environmental conditions. Natural organic matter (NOM) has a large influence, as it can attenuate radiation and thus decrease inactivation by endogenous mechanisms. Simultaneously NOM sensitizes the formation of reactive intermediates that can damage microorganisms via exogenous mechanisms. To accurately predict inactivation and design engineered systems that enhance solar inactivation, it is necessary to model these processes, although some details are not yet sufficiently well understood. In this critical review, we summarize the photo-physics, -chemistry, and -biology that underpin sunlight-mediated inactivation, as well as the targets of damage and cellular responses to sunlight exposure. Viruses that are not susceptible to exogenous inactivation are only inactivated if UVB wavelengths (280-320 nm) are present, such as in very clear, open waters or in containers that are transparent to UVB. Bacteria are susceptible to slightly longer wavelengths. Some viruses and bacteria (especially Gram-positive) are susceptible to exogenous inactivation, which can be initiated by visible as well as UV wavelengths. We review approaches to model sunlight-mediated inactivation and illustrate how the environmental conditions can dramatically shift the inactivation rate of organisms. The implications of this mechanistic understanding of solar inactivation are discussed for a range of applications, including recreational water quality, natural treatment systems, solar disinfection of drinking water (SODIS), and enhanced inactivation via the use of sensitizers and photocatalysts. Finally, priorities for future research are identified that will further our understanding of the key role that sunlight disinfection plays in natural systems and the potential to enhance this process in engineered systems.
Display omitted
•Review of persulphate (PS) OO bond.•The behaviour of silver(I) activation.•Objections to Fe3++S2O82-→Fe2++S2O8·-.•Modified alkaline activation mechanism.•Optimal activation ...temperature.
Persulphate advanced oxidation processes (PS-AOPs) constitute an important development in the field of wastewater treatment and subsurface contamination remediation within the last two decades. Although persulphate (PS) is a very powerful oxidant, its reaction with common contaminants is relatively slow so that to achieve pollutant degradation at an acceptable rate, activation to produce reactive radicals such as sulphate and hydroxyl radicals is often necessary. Consequently, research in PS-AOPs is dominated by the search for cost-effective and sustainable activation techniques. This review provides a critical evaluation of various published techniques for the activation of PS, suggests novel explanations for important observations in the field and advances proposals to explain reaction mechanisms more consistently. Discrepancies in results and areas for further studies were identified with the view of enhancing the sustainability and reliability of PS-AOPs.
This study provides an overview of established processes as well as recent progress in emerging technologies for advanced oxidation processes (AOPs). In addition to a discussion of major reaction ...mechanisms and formation of by-products, data on energy efficiency were collected in an extensive analysis of studies reported in the peer-reviewed literature enabling a critical comparison of various established and emerging AOPs based on electrical energy per order (EEO) values. Despite strong variations within reviewed EEO values, significant differences could be observed between three groups of AOPs: (1) O3 (often considered as AOP-like process), O3/H2O2, O3/UV, UV/H2O2, UV/persulfate, UV/chlorine, and electron beam represent median EEO values of <1 kWh/m3, while median energy consumption by (2) photo-Fenton, plasma, and electrolytic AOPs were significantly higher (EEO values in the range of 1–100 kWh/m3). (3) UV-based photocatalysis, ultrasound, and microwave-based AOPs are characterized by median values of >100 kWh/m3 and were therefore considered as not (yet) energy efficient AOPs. Specific evaluation of 147 data points for the UV/H2O2 process revealed strong effects of operational conditions on reported EEO values. Besides water type and quality, a major influence was observed for process capacity (lab-vs. pilot-vs. full-scale applications) and, in case of UV-based processes, of the lamp type. However, due to the contribution of other factors, correlation of EEO values with specific water quality parameters such as UV absorbance and dissolved organic carbon were not substantial. Also, correlations between EEO and compound reactivity with OH-radicals were not significant (photolytically active compounds were not considered). Based on these findings, recommendations regarding the use of the EEO concept, including the upscaling of laboratory results, were derived.
Display omitted
•Short summary of radical generation mechanisms and application of AOPs.•First comparison of published EEO values across different AOPs.•Critical consideration of influencing factors on reported EEO values within UV/H2O2.•Proposal for proper use of the EEO-concept.•Discussion of major oxidation by-product formation mechanisms.
Ultraviolet light emitting diodes (UV LEDs) have increasing applications in the inactivation of microorganisms in water, air, food, and on surfaces. System designers currently have metrics for ...comparison of the microbial and energy efficiency of UV LEDs, but these have not included a time component. Without including the time efficiency of a UV LED, neither the fluence-basis nor the electrical-basis of comparison clarifies which UV LED wavelength and operating condition is optimal for a design space. This research explores microbial inactivation of UV LEDs at various wavelengths under continuous and pulsing operating conditions. Planktonic microorganisms of relevance to public water supplies and UV system design are included: E. coli and MS-2 for benchmarking against previous studies and P. aeruginosa which has not been studied in pulsed systems or for continuous and combined UV LED wavelengths.
Pulsing UV LEDs at various duty rates (percent of cycle spent on) and frequencies (number of cycles per second) does not result in a statistically significant disinfection performance difference over the continuous light operation at that respective wavelength. UV LEDs emitting at peak wavelengths corresponding to the peak action spectrum of a microorganism are optimal on a fluence-basis, but these are typically less electrically efficient UV LEDs. System designers can compare the normalized microbial inactivation, electrical, and time efficiencies (ENETO) of various UV LEDs; ENETO ≥1 for a pulsing condition ensures equal or improved efficiency compared to the continuous light condition while expanding the lifetime of the UV LED and decreasing the size or cost of associated power supplies.
Display omitted
•255–285 nm UV LEDs effectively inactivate microorganisms in drinking water.•Pulsing UV LEDs does not result in a difference in disinfection over continuous UV.•Peak wavelengths that overlap microbe action spectra are optimal on a fluence-basis.•Electrical-basis comparisons favor higher irradiance output UV LEDs.•ENETO calculates microbial, electrical, and time efficiencies for optimized design.
Effective disinfection technology to combat severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can help reduce viral transmission during the ongoing COVID-19 global pandemic and in the ...future. UV devices emitting UVC irradiation (200 to 280 nm) have proven to be effective for virus disinfection, but limited information is available for SARS-CoV-2 due to the safety requirements of testing, which is limited to biosafety level 3 (BSL3) laboratories. In this study, inactivation of SARS-CoV-2 in thin-film buffered aqueous solution (pH 7.4) was determined across UVC irradiation wavelengths of 222 to 282 nm from krypton chloride (KrCl*) excimers, a low-pressure mercury-vapor lamp, and two UVC light-emitting diodes. Our results show that all tested UVC devices can effectively inactivate SARS-CoV-2, among which the KrCl* excimer had the best disinfection performance (i.e., highest inactivation rate). The inactivation rate constants of SARS-CoV-2 across wavelengths are similar to those for murine hepatitis virus (MHV) from our previous investigation, suggesting that MHV can serve as a reliable surrogate of SARS-CoV-2 with a lower BSL requirement (BSL2) during UV disinfection tests. This study provides fundamental information on UVC's action on SARS-CoV-2 and guidance for achieving reliable disinfection performance with UVC devices.
UV light is an effective tool to help stem the spread of respiratory viruses and protect public health in commercial, public, transportation, and health care settings. For effective use of UV, there is a need to determine the efficiency of different UV wavelengths in killing pathogens, specifically SARS-CoV-2, to support efforts to control the ongoing COVID-19 global pandemic and future coronavirus-caused respiratory virus pandemics. We found that SARS-CoV-2 can be inactivated effectively using a broad range of UVC wavelengths, and 222 nm provided the best disinfection performance. Interestingly, 222-nm irradiation has been found to be safe for human exposure up to thresholds that are beyond those effective for inactivating viruses. Therefore, applying UV light from KrCl* excimers in public spaces can effectively help reduce viral aerosol or surface-based transmissions.
Conspectus This work critically evaluates the current paradigm of water distribution system management and juxtaposes that with the potential benefits of employing UV irradiation, which we hope will ...catalyze a judicial re-evaluation of the current practices in water distribution system management and spur critical research and a new way of thinking about secondary disinfection across the extent of distribution systems. Given the recent advances in UV technology and the efficacy of UV disinfection against all pathogen classes, we now see UV applications for disinfection in many aspects of consumers lives: in water coolers, dishwashers, coffee makers, and disinfection of personal items like gym bags, water bottles, and toothbrushes. Public and regulatory concern over water quality and pathogens, especially the recent interest in building plumbing, calls out for new approaches to disinfection and distribution system management. We envision a new model for secondary disinfection in water distribution systems utilizing emerging germicidal UV LED-based disinfection. UV irradiation in water treatment can achieve high levels of disinfection of all pathogens and minimize or eliminate the formation of regulated disinfection byproducts. So why is UV not considered as a secondary disinfectant for distribution systems? In this Account, we lay out the logic as to the benefits and practicality of adding distributed UV treatment to assist in protection of distribution systems and protect water quality for human exposure. The possible locations of UV irradiation in distribution systems are envisioned, potentially including UV booster stations along the distribution network, UV in storage tanks or their inlet/outlets, LEDs distributed along pipe walls, small point of use/entry treatment systems for buildings/homes/taps, or submersible swimming or rolling UV LED drones to reach problem pipes and provide a “shock” treatment or provide sterilization after main breaks or repairs. The benefits of UV applications in water also include high effectiveness against chlorine-resistant protozoa, no added disinfection byproducts, and compatibility of adding of UV to existing secondary disinfection strategies for enhanced protection. Potential challenges and research needs are described, such as use of UV-compatible pipe materials, implementation of sensors to monitor distributed LEDs, management of waste heat from the rear surface of the LED, and understanding the potential for regrowth of opportunistic microorganisms. Another notable challenge is the relatively stagnant regulatory environment in some countries to develop frameworks for evaluation and acceptance of UV technology in distribution systems that require a chemical secondary disinfectant. Rapid advances in UV LED research has propelled the growth of this field, but needs still remain, including understanding behavior of biofilms in pipes under UV irradiation, including any beneficial effects that may be lost, the potential for fouling of LED emission surfaces and monitoring points, and provision of a distributed power network to run the LEDs. Regulators may want specific monitoring approaches and advances in real-time monitoring of microbial viability, and engineers may need to develop new approaches to overall management.
The advantages of polychromatic ultraviolet (UV) light for viral disinfection can be optimized for disinfection using emerging tailored wavelength sources including KrCl excimer lamps and light ...emitting diodes (LEDs). Disinfection of the common viral surrogate MS2 bacteriophage was measured after exposure to these emerging sources and conventional low pressure (LP) mercury UV lamps in individual or sequential exposures. The first dose response for any virus (MS2) exposed to a KrCl excimer lamp is reported, showing the high efficiency of fluence-based disinfection because of increased viral susceptibility at the low wavelengths emitted by the excilamp. Sequential exposure dose responses indicated synergy from sequential exposures of LP and excimer lamps, which were competitive on an electrical basis at worst-and best-case scenarios of wall plug efficiency with current medium pressure (MP) disinfection. Best-case scenarios for electrical efficiency also showed all sequential exposures to be competitive with MP UV disinfection. Predictive models for sequential exposure dose responses were assessed to support the current feasibility of incorporating sequential UV exposures to optimize tailored wavelength viral disinfection.
Display omitted
•KrCl excilamps rival conventional mercury lamps for viral disinfection.•Sequential exposure by UV-C LEDs, excilamp, and LP is beneficial for disinfection.•MS2 inactivation was synergistically enhanced by both sequences of KrCl and LP lamps.•MS2 inactivation was synergistically enhanced by KrCl or LP lamps before LEDs.•Predictive models can be used to plan and optimize wavelength-tailored disinfection.
Trace levels of antibiotics in treated wastewater effluents may present a human health risk due to the rise of antibacterial activity in the downstream environments. Advanced oxidation has a ...potential to become an effective treatment technology for transforming trace antibiotics in wastewater effluents, but residual or newly generated antibacterial properties of transformation products are a concern. This study demonstrates the effect of UV photolysis and UV/H2O2 advanced oxidation on transformation of 6 antibiotics, each a representative of a different structural class, in pure water and in two different effluents and reports new or confirmatory photolysis quantum yields and hydroxyl radical rate constants. The decay of the parent compound was monitored with HPLC/ITMS, and the corresponding changes in antibacterial activity were measured using bacterial inhibition assays. No antibacterially active products were observed following treatment for four of the six antibiotics (clindamycin, ciprofloxacin, penicillin-G, and trimethoprim). The remaining two antibiotics (erythromycin and doxycycline) showed some intermediates with antibacterial activity at low treatment doses. The antibacterially active products lost activity as the UV dose increased past 500 mJ/cm2. Active products were observed only in wastewater effluents and not in pure water, suggesting that complex secondary reactions controlled by the composition of the matrix were responsible for their formation. This outcome emphasizes the importance of bench-scale experiments in realistic water matrices. Most importantly, the results indicate that photosensitized processes during high dose wastewater disinfection may be creating antibacterially active transformation products from some common antibiotics.
A dual-wavelength UV-C LED unit, emitting at peaks of 260 nm, 280 nm, and the combination of 260|280 nm together was evaluated for its inactivation efficacy and energy efficiency at disinfecting ...Escherichia coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores, compared to conventional low-pressure and medium-pressure UV mercury vapor lamps. The dual-wavelength unit was also used to measure potential synergistic effects of multiple wavelengths on bacterial and viral inactivation and DNA and RNA damage.
All five UV sources demonstrated similar inactivation of E. coli. For MS2, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was most effective. When measuring electrical energy per order of reduction, the LP UV lamp was most efficient for inactivating E. coli and MS2; the LP UV and MP UV mercury lamps were equally efficient for HAdV2 and B. pumilus spores. Among the UV-C LEDs, there was no statistical difference in electrical efficiency for inactivating MS2, HAdV2, and B. pumilus spores. The 260 nm and 260|280 nm LEDs had a statistical energy advantage for E. coli inactivation.
For UV-C LEDs to match the electrical efficiency per order of log reduction of conventional LP UV sources, they must reach efficiencies of 25–39% or be improved on by smart reactor design. No dual wavelength synergies were detected for bacterial and viral inactivation nor for DNA and RNA damage.
Display omitted
•Evaluated UV-C LED inactivation of E. coli, MS2, Adenovirus 2 and B. pumilus spores.•Compared UV-C LEDs to LP and MP UV lamps for inactivation and energy efficiency.•Confirmed absence of dual-wavelength synergy for inactivation and DNA/RNA damage.•UV-C LEDs will require efficiencies of 25–39% to match performance of LP UV lamps.
Novel UV sources, which do not contain mercury, provide the opportunity for enhancement of current oxidation technologies through spectral optimization, minimizing inefficiencies that currently limit ...conventional technology. Wastewater reuse is the primary full-scale application of UV advanced oxidation processes (AOPs) in practice but any background absorbance and the low molar absorption by conventional radical promoters (hydrogen peroxide) have historically limited their system efficiency, resulting in the underutilization of photons in a reactor. This bench-scale research evaluated use of longer wavelength UV light emitting diodes (265, 280, and 300 nm) matched with free chlorine to optimize the utilization of photons for advanced oxidation. Free chlorine possesses large absorption bands in the 280 to 300 nm range in basic pH waters which are common in carbon-based reuse and was used to experimentally verify quantum yields of hydroxyl radical generation across the UV LED peak emission wavelengths. pH- and wavelength-dependent fluence-based rate constants were experimentally derived using Nitrobenzene and Benzoic acid as probe compounds and evaluated to determine the contribution of the hydroxyl and chlorine radical. Reclaimed water taken from various advanced treatment steps was treated with this UV LED AOP to investigate how background absorbance affects radical generation and contaminant transformation kinetics. In addition, alternative performance metrics to evaluate hydroxyl radical production at different incident fluence rates and different rates of photon absorption at unique wavelengths across varying background UV absorbance levels were assessed.