Approximately one-quarter of adnexal masses detected at ultrasonography are indeterminate for benignity or malignancy, posing a substantial clinical dilemma.
To validate the accuracy of a 5-point ...Ovarian-Adnexal Reporting Data System Magnetic Resonance Imaging (O-RADS MRI) score for risk stratification of adnexal masses.
This multicenter cohort study was conducted between March 1, 2013, and March 31, 2016. Among patients undergoing expectant management, 2-year follow-up data were completed by March 31, 2018. A routine pelvic MRI was performed among consecutive patients referred to characterize a sonographically indeterminate adnexal mass according to routine diagnostic practice at 15 referral centers. The MRI score was prospectively applied by 2 onsite readers and by 1 reader masked to clinical and ultrasonographic data. Data analysis was conducted between April and November 2018.
The primary end point was the joint analysis of true-negative and false-negative rates according to the MRI score compared with the reference standard (ie, histology or 2-year follow-up).
A total of 1340 women (mean range age, 49 18-96 years) were enrolled. Of 1194 evaluable women, 1130 (94.6%) had a pelvic mass on MRI with a reference standard (surgery, 768 67.9%; 2-year follow-up, 362 32.1%). A total of 203 patients (18.0%) had at least 1 malignant adnexal or nonadnexal pelvic mass. No invasive cancer was assigned a score of 2. Positive likelihood ratios were 0.01 for score 2, 0.27 for score 3, 4.42 for score 4, and 38.81 for score 5. Area under the receiver operating characteristic curve was 0.961 (95% CI, 0.948-0.971) among experienced readers, with a sensitivity of 0.93 (95% CI, 0.89-0.96; 189 of 203 patients) and a specificity of 0.91 (95% CI, 0.89-0.93; 848 of 927 patients). There was good interrater agreement among both experienced and junior readers (κ = 0.784; 95% CI, 0.743-0824). Of 580 of 1130 women (51.3%) with a mass on MRI and no specific gynecological symptoms, 362 (62.4%) underwent surgery. Of them, 244 (67.4%) had benign lesions and a score of 3 or less. The MRI score correctly reclassified the mass origin as nonadnexal with a sensitivity of 0.99 (95% CI, 0.98-0.99; 1360 of 1372 patients) and a specificity of 0.78 (95% CI, 0.71-0.85; 102 of 130 patients).
In this study, the O-RADS MRI score was accurate when stratifying the risk of malignancy in adnexal masses.
Concurrent chemoradiotherapy (CRT) with blockade of the PD-1 pathway may enhance immune-mediated tumor control through increased phagocytosis, cell death, and antigen presentation. The NiCOL phase 1 ...trial (NCT03298893) is designed to determine the safety/tolerance profile and the recommended phase-II dose of nivolumab with and following concurrent CRT in 16 women with locally advanced cervical cancer. Secondary endpoints include objective response rate (ORR), progression free survival (PFS), disease free survival, and immune correlates of response. Three patients experience grade 3 dose-limiting toxicities. The pre-specified endpoints are met, and overall response rate is 93.8% 95%CI: 69.8-99.8% with a 2-year PFS of 75% 95% CI: 56.5-99.5%. Compared to patients with progressive disease (PD), progression-free (PF) subjects show a brisker stromal immune infiltrate, higher proximity of tumor-infiltrating CD3
T cells to PD-L1
tumor cells and of FOXP3
T cells to proliferating CD11c
myeloid cells. PF show higher baseline levels of PD-1 and ICOS-L on tumor-infiltrating EMRA CD4
T cells and tumor-associated macrophages, respectively; PD instead, display enhanced PD-L1 expression on TAMs, higher peripheral frequencies of proliferating Tregs at baseline and higher PD-1 levels at week 6 post-treatment initiation on CD4 and CD8 T cell subsets. Concomitant nivolumab plus definitive CRT is safe and associated with encouraging PFS rates. Further validation in the subset of locally advanced cervical cancer displaying pre-existing, adaptive immune activation is warranted.
Perfusion-related complications remain the most common concern in DIEP flap breast reconstruction. Indocyanine green-based fluorescence angiography can be used for the real-time intra operative ...assessment of flap perfusion. The SPY Elite system is the most widely used device in this setting. The main objective was to describe the use of SPY-Q proprietary software to perform qualitative and quantitative analysis of flap perfusion.
This retrospective cohort study was performed at the Curie Institute between 2013 and 2017. We included patients undergoing unilateral DIEP flap breast reconstruction for whom indocyanine green-based angiography videos were of sufficient quality for analysis. Videos were recorded with the SPY Elite System and analyzed with SPY-Q proprietary software.
We included 40 patients. We used real-time dynamic color analysis to describe three different patterns of flap perfusion. SPY-Q proprietary software provides quantitative flap perfusion parameters. Our quantitative analysis confirmed that zone I is the best perfused part of the flap and zone IV the less perfused one. There was no significant association between flap perfusion pattern and perforator anatomy, patients' clinical characteristics or postoperative outcomes. After exploratory univariate analysis, quantitative perfusion parameters were significantly impaired in young patients with diabetes mellitus or under hormone therapy by tamoxifen.
We here describe a new approach to assess DIEP flap perfusion using the SPY Elite System proprietary software. It provides interesting qualitative and quantitative analysis that can be used in further studies to precisely assess DIEP flap perfusion.
Hyperechogenicity is a sign classically reported to be in favour of a benign lesion and can be observed in many types of benign breast lesions such as hamartoma, lipoma, angiolipoma, haemangioma, ...haematoma, fat necrosis, fibrosis and galactocele, among others. However, some rare malignant breast lesions can also present a hyperechoic appearance. Most of these hyperechoic malignant lesions present other characteristics that are more typically suggestive of malignancy such as posterior shadowing, a more vertical axis or irregular margins that help to guide the diagnosis. Post magnetic resonance imaging, second-look ultrasound may visualise hyperechoic malignant lesions that would not have been identified at first sight and radiologists must know how to recognise these lesions.
Teaching Points
• Some rare malignant breast lesions can present a hyperechoic appearance.
• Malignant lesions present other characteristics that are suggestive of malignancy.
• An echogenic mass with fat density on mammography does not require biopsy.
Purpose
The second International Consensus Conference on B3 lesions was held in Zurich, Switzerland, in March 2018, organized by the International Breast Ultrasound School to re-evaluate the ...consensus recommendations.
Methods
This study (1) evaluated how management recommendations of the first Zurich Consensus Conference of 2016 on B3 lesions had influenced daily practice and (2) reviewed current literature towards recommendations to biopsy.
Results
In 2018, the consensus recommendations for management of B3 lesions remained almost unchanged: For flat epithelial atypia (FEA), classical lobular neoplasia (LN), papillary lesions (PL) and radial scars (RS) diagnosed on core-needle biopsy (CNB) or vacuum-assisted biopsy (VAB), excision by VAB in preference to open surgery, and for atypical ductal hyperplasia (ADH) and phyllodes tumors (PT) diagnosed at VAB or CNB, first-line open surgical excision (OE) with follow-up surveillance imaging for 5 years. Analyzing the Database of the Swiss Minimally Invasive Breast Biopsies (MIBB) with more than 30,000 procedures recorded, there was a significant increase in recommending more frequent surveillance of LN 65% in 2018 vs. 51% in 2016 (
p
= 0.004), FEA (72% in 2018 vs. 62% in 2016 (
p
= 0.005)), and PL (76% in 2018 vs. 70% in 2016 (
p
= 0.04) diagnosed on VAB. A trend to more frequent surveillance was also noted also for RS 77% in 2018 vs. 67% in 2016 (
p
= 0.07).
Conclusions
Minimally invasive management of B3 lesions (except ADH and PT) with VAB continues to be appropriate as an alternative to first-line OE in most cases, but with more frequent surveillance, especially for LN.
Objective
Quantitative analysis in MRI is challenging due to variabilities in intensity distributions across patients, acquisitions and scanners and suffers from bias field inhomogeneity. Radiomic ...studies are impacted by these effects that affect radiomic feature values. This paper describes a dedicated pipeline to increase reproducibility in breast MRI radiomic studies.
Materials and methods
T1, T2, and T1-DCE MR images of two breast phantoms were acquired using two scanners and three dual breast coils. Images were retrospectively corrected for bias field inhomogeneity and further normalised using
Z
score or histogram matching. Extracted radiomic features were harmonised between coils by the ComBat method. The whole pipeline was assessed qualitatively and quantitatively using statistical comparisons on two series of radiomic feature values computed in the gel mimicking the normal breast tissue or in dense lesions.
Results
Intra and inter-acquisition variabilities were strongly reduced by the standardisation pipeline. Harmonisation by ComBat lowered the percentage of radiomic features significantly different between the three coils from 87% after bias field correction and MR normalisation to 3% in the gel, while preserving or improving performance of lesion classification in the phantoms.
Discussion
A dedicated standardisation pipeline was developed to reduce variabilities in breast MRI, which paves the way for robust multi-scanner radiomic studies but needs to be assessed on patient data.
•ADH found on percutaneous breast biopsy currently raises management issues.•We tested a previously defined decision tree to help obviate unnecessary surgery.•Our results support this decision tree ...with a 5% upgrade in non-operated patients.
Atypical lesions found on percutaneous breast biopsy raise specific management issues. The aim of this study was to validate the previous performance of a decision tree defined by Forgeard et al to select a subset of patients at low-risk of surgical diagnostic upgrade that would be eligible for surveillance.
A consecutive series of 211 patients diagnosed with ADH on vacuum-assisted biopsy (VAB) of clustered microcalcifications alone, then operated in our institution, was reviewed. Histological findings on percutaneous cores were compared with definitive diagnoses on surgical specimens. The rate of cancer underestimation on VAB was analyzed in the four arms and two management attitudes defined in the scheme, using size and quality of microcalcification removal and the number of ADH foci.
Ninety-eight women with ADH met the inclusion criteria. Overall, 20 cancers were diagnosed at surgery, showing a malignancy rate of 44% (17/39 patients) in the surgery group and of 5% (3/59 patients) in the surveillance group, which was not significantly different from the 2% rate in the monitored reference group (p > 0.64). The malignancy rate increased significantly with the size of clustered microcalcifications (0% when < 6mm, 17% when between 6mm and 21 mm, 48% when > 21 mm, p < 0001) and the number of ADH foci on VAB (14% when ≤ 2, 45% when > 2, p < 0.005).
Our results corroborate – within the limits of large confidence intervals – those obtained with the reference decision tree. Due to statistical uncertainty, however, they need to be prospectively validated in a broader series.