Essential Oil of Salvia lereifolia Benth Rustaiyan, Abdolhossein; Masoudi, Shiva; Yari, Mohammad ...
The Journal of essential oil research,
09/2000, Letnik:
12, Številka:
5
Journal Article
Recenzirano
The essential oil isolated by hydrodistillation from the aerial parts of Salvia lereifolia Benth. was analyzed using GC (retention indices) and GC/MS. Twenty-two components representing 93.4% of the ...oil were characterized. The major constituents found were β-pinene (23.7%), 1,8-cineole (16.2%), α-pinene (13.8%) and α-cadinol (9.0%).
Rationale: Computer aided detection (CAD) algorithms for Pulmonary Embolism (PE) algorithms have been shown to increase radiologists' sensitivity with a small increase in specificity. However, CAD ...for PE has not been adopted into clinical practice, likely because of the high number of false positives current CAD software produces. Objective: To generate a database of annotated computed tomography pulmonary angiographies, use it to compare the sensitivity and false positive rate of current algorithms and to develop new methods that improve such metrics. Methods: 91 Computed tomography pulmonary angiography scans were annotated by at least one radiologist by segmenting all pulmonary emboli visible on the study. 20 annotated CTPAs were open to the public in the form of a medical image analysis challenge. 20 more were kept for evaluation purposes. 51 were made available post-challenge. 8 submissions, 6 of them novel, were evaluated on the 20 evaluation CTPAs. Performance was measured as per embolus sensitivity vs. false positives per scan curve. Results: The best algorithms achieved a per-embolus sensitivity of 75% at 2 false positives per scan (fps) or of 70% at 1 fps, outperforming the state of the art. Deep learning approaches outperformed traditional machine learning ones, and their performance improved with the number of training cases. Significance: Through this work and challenge we have improved the state-of-the art of computer aided detection algorithms for pulmonary embolism. An open database and an evaluation benchmark for such algorithms have been generated, easing the development of further improvements. Implications on clinical practice will need further research.
There has been tremendous progress in the performance of optical frequency
standards since the first proposals to carry out precision spectroscopy on
trapped, single ions in the 1970s. The estimated ...fractional frequency
uncertainty of today's leading optical standards is currently in the $10^{-18}$
range, approximately two orders of magnitude better than that of the best
caesium primary frequency standards. This exceptional accuracy and stability is
resulting in a growing number of research groups developing optical clocks.
While good review papers covering the topic already exist, more practical
guidelines are needed as a complement. The purpose of this document is
therefore to provide technical guidance for researchers starting in the field
of optical clocks. The target audience includes national metrology institutes
(NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD
students and postdocs entering the field. Another potential audience is
academic groups with experience in atomic physics and atom or ion trapping, but
with less experience of time and frequency metrology and optical clock
requirements. These guidelines have arisen from the scope of the EMPIR project
"Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the
examples are from European laboratories even though similar work is carried out
all over the world. The goal of OC18 was to push the development of optical
clocks by improving each of the necessary subsystems: ultrastable lasers,
neutral-atom and single-ion traps, and interrogation techniques. This document
shares the knowledge acquired by the OC18 project consortium and gives
practical guidance on each of these aspects.
Clustering protein-protein interaction network aims to find functional modules and protein complexes. There are many computational graph clustering methods that are used in this field, but few of ...them are intelligent computational methods. In this paper, we present a novel improved immune genetic algorithm to find dense subgraphs based on efficient vaccination method, variable-length antibody schema definition and new local and global mutations.
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated ...fractional frequency uncertainty of today's leading optical standards is currently in the \(10^{-18}\) range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with \(1 \times 10^{-18}\) uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.