Abstract
Objectives
To establish the optimal parameters for group testing of pooled specimens for the detection of SARS-CoV-2.
Methods
The most efficient pool size was determined to be five specimens ...using a web-based application. From this analysis, 25 experimental pools were created using 50 µL from one SARS-CoV-2 positive nasopharyngeal specimen mixed with 4 negative patient specimens (50 µL each) for a total volume of 250 µL. Viral RNA was subsequently extracted from each pool and tested using the CDC SARS-CoV-2 RT-PCR assay. Positive pools were consequently split into individual specimens and tested by extraction and PCR. This method was also tested on an unselected group of 60 nasopharyngeal specimens grouped into 12 pools.
Results
All 25 pools were positive with cycle threshold (Ct) values within 0 and 5.03 Ct of the original individual specimens. The analysis of 60 specimens determined that 2 pools were positive followed by identification of 2 individual specimens among the 60 tested. This testing was accomplished while using 22 extractions/PCR tests, a savings of 38 reactions.
Conclusions
When the incidence rate of SARS-CoV-2 infection is 10% or less, group testing will result in the saving of reagents and personnel time with an overall increase in testing capability of at least 69%.
Shiga-toxin producing Escherichia coli (STEC) O26:H11 is the second most common cause of severe diarrhea and hemolytic uremic syndrome worldwide. The implementation of whole genome sequencing (WGS) ...enhances the detection and in-depth characterization of these non-O157 STEC strains. The aim of this study was to compare WGS to phenotypic serotyping and pulse field gel electrophoresis (PFGE) for characterization of STECO26 strains following a zoonotic outbreak from cattle to humans.
This study evaluated seven E. coli strains; two strains isolated from two children with gastrointestinal symptoms and five strains from five calves suspected as the source of infection. Six of these isolates were serotyped phenotypically and by WGS as E. coli O26:H11 while one bovine isolate could be serotyped only by WGS as E. coli O182:H25. Stx1 was detected in two human- and two bovine-isolates using PCR and WGS. Using WGS, all four STECO26 isolates belong to sequence type (ST) 21 while the two stx1 negative E. coli O26 were ST29. All four STECO26 isolates were indistinguishable by PFGE. However, the data generated by WGS linked the two human STECO26 isolates to only one bovine STECO26 strain by having identical high-quality single nucleotide polymorphisms (hqSNPs) and identical virulence factor profiles while the remaining bovine STECO26 isolate differed by 7 hqSNPs and lacked virulence factor toxB.
These data demonstrated that WGS provided significant information beyond traditional epidemiological tools allowing for comprehensive characterization of the STEC. Using this approach, WGS was able to identify the specific source of infection in this study.
subsp.
serovar Corvallis is commonly reported in avian populations and avian by-products. We report the draft genome sequence of a multidrug-resistant
Corvallis strain (NPHL 15376). To our knowledge, ...this is the first reported case of this serovar isolated from human blood in the United States.
Shiga toxin-producing
(STEC) is a foodborne disease with worldwide outbreaks. STEC serotypes O157, O26, O45, O103, O111, O121, and O145 cause the most outbreaks. There is little published information ...regarding the other serotypes. We report the draft genome sequences for 11 uncommon STEC serotypes from Nebraska.
serovar Dublin, which can cause enteritis and systemic infections in humans, has been associated with antimicrobial resistance. Here, we report draft genome sequences of seven multidrug-resistant
...Dublin isolates from human samples. These sequences will contribute to an understanding of pathogenesis and resistance determinants in this serovar.
As part of public health preparedness for infectious disease threats, CDC collaborates with other U.S. public health officials to ensure that the Laboratory Response Network (LRN) has diagnostic ...tools to detect Orthopoxviruses, the genus that includes Variola virus, the causative agent of smallpox. LRN is a network of state and local public health, federal, U.S. Department of Defense (DOD), veterinary, food, and environmental testing laboratories. CDC developed, and the Food and Drug Administration (FDA) granted 510(k) clearance* for the Non-variola Orthopoxvirus Real-time PCR Primer and Probe Set (non-variola Orthopoxvirus NVO assay), a polymerase chain reaction (PCR) diagnostic test to detect NVO. On May 17, 2022, CDC was contacted by the Massachusetts Department of Public Health (DPH) regarding a suspected case of monkeypox, a disease caused by the Orthopoxvirus Monkeypox virus. Specimens were collected and tested by the Massachusetts DPH public health laboratory with LRN testing capability using the NVO assay. Nationwide, 68 LRN laboratories had capacity to test approximately 8,000 NVO tests per week during June. During May 17-June 30, LRN laboratories tested 2,009 specimens from suspected monkeypox cases. Among those, 730 (36.3%) specimens from 395 patients were positive for NVO. NVO-positive specimens from 159 persons were confirmed by CDC to be monkeypox; final characterization is pending for 236. Prompt identification of persons with infection allowed rapid response to the outbreak, including isolation and treatment of patients, administration of vaccines, and other public health action. To further facilitate access to testing and increase convenience for providers and patients by using existing provider-laboratory relationships, CDC and LRN are supporting five large commercial laboratories with a national footprint (Aegis Science, LabCorp, Mayo Clinic Laboratories, Quest Diagnostics, and Sonic Healthcare) to establish NVO testing capacity of 10,000 specimens per week per laboratory. On July 6, 2022, the first commercial laboratory began accepting specimens for NVO testing based on clinician orders.